Two thermal methods to measure the energy fluence of a brief exposure of diagnostic x rays
| dc.contributor.author | Carvalho, A. A. | |
| dc.contributor.author | Mascarenhas, S. | |
| dc.contributor.author | DePaula, M. H. | |
| dc.contributor.author | Cameron, J. R. | |
| dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
| dc.date.accessioned | 2014-05-27T11:17:28Z | |
| dc.date.available | 2014-05-27T11:17:28Z | |
| dc.date.issued | 1992-07-03 | |
| dc.description.abstract | This paper describes two simple thermal methods for measuring the energy fluence in J/cm 2 from a diagnostic x-ray exposure. Both detectors absorb essentially 100% of the radiation and give a signal that is directly proportional to the energy fluence of the x-ray beam. One detector measures the thermal effect when a pulse of x rays is totally absorbed in the pyroelectric detector of lead-zirconium-titanate (PZT). The other detector measures the expansion of a gas surrounding a lead disk detector in a photoacoustic chamber. The increased pressure of the gas is transmitted through a 1-mm duct to a sensitive microphone. Both detectors have previously been used to measure the energy fluence rate of continuous x-ray beams in the same energy region using a chopped beam and a lock-in amplifier. Measurement of the energy fluence of a pulse of radiation eliminates the need for the beam chopper and lock-in amplifier and results in a simple, rugged, and inexpensive dosimeter. Either method can be combined with the area of the beam to give an estimate of the imparted energy to the patient from a diagnostic x-ray exposure. | en |
| dc.description.affiliation | Departamento de Engenharia Electrica Univ. Est. Paulista, C.P. 31, Ilha Solteira, S.P. CEP 15378 | |
| dc.format.extent | 575-577 | |
| dc.identifier | http://dx.doi.org/10.1118/1.596912 | |
| dc.identifier.citation | Medical Physics, v. 19, n. 3, p. 575-577, 1992. | |
| dc.identifier.doi | 10.1118/1.596912 | |
| dc.identifier.issn | 0094-2405 | |
| dc.identifier.scopus | 2-s2.0-0026650632 | |
| dc.identifier.uri | http://hdl.handle.net/11449/64249 | |
| dc.language.iso | eng | |
| dc.relation.ispartof | Medical Physics | |
| dc.relation.ispartofjcr | 2.884 | |
| dc.relation.ispartofsjr | 1,289 | |
| dc.rights.accessRights | Acesso restrito | |
| dc.source | Scopus | |
| dc.subject | diagnostic x ray | |
| dc.subject | energy fluence | |
| dc.subject | imparted energy | |
| dc.subject | photoacoustic | |
| dc.subject | pyroelectric | |
| dc.subject | acoustics | |
| dc.subject | algorithm | |
| dc.subject | dosimeter | |
| dc.subject | human | |
| dc.subject | ionization chamber | |
| dc.subject | priority journal | |
| dc.subject | radiation absorption | |
| dc.subject | radiation beam | |
| dc.subject | radiation energy | |
| dc.subject | radiation exposure | |
| dc.subject | radiation scattering | |
| dc.subject | radiodiagnosis | |
| dc.subject | signal noise ratio | |
| dc.subject | thermal analysis | |
| dc.subject | waveform | |
| dc.subject | X ray | |
| dc.subject | Energy Transfer | |
| dc.subject | Human | |
| dc.subject | Radiation Dosage | |
| dc.subject | Radiography | |
| dc.subject | Support, Non-U.S. Gov't | |
| dc.subject | X-Rays | |
| dc.title | Two thermal methods to measure the energy fluence of a brief exposure of diagnostic x rays | en |
| dc.type | Artigo | |
| dcterms.license | http://scitation.aip.org/termsconditions | |
| dspace.entity.type | Publication | |
| unesp.author.lattes | 0250066159980825[1] | |
| unesp.author.orcid | 0000-0001-8204-3482[1] |