Logo do repositório
 

UV filters in water samples: Experimental design on the SPE optimization followed by GC-MS/MS analysis

dc.contributor.authorDa Silva, Claudia P. [UNESP]
dc.contributor.authorEmídio, Elissandro S. [UNESP]
dc.contributor.authorMarchi, Mary Rosa Rodrigues de [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:30:36Z
dc.date.available2014-05-27T11:30:36Z
dc.date.issued2013-09-01
dc.description.abstractEsse estudo descreve o desenvolvimento e otimização de um método de extração em fase solida (SPE) para análise dos filtros ultravioletas (UV): benzofenona-3 (BP-3), etilhexil salicilato (ES), etilhexil metoxinamato (EHMC) e octocrileno (OC) em matrizes ambientais. Um planejamento fatorial fracionário (PFF) 25-1 foi empregado na avaliação das variáveis significativas do método de extração. As condições experimentais otimizadas da avaliação estatística foram: capacidade do cartucho de 500 mL, eluente acetato de etila, metanol como solvente de lavagem (10% em água, v/v) and volume do eluente de 3 × 2 mL e pH 3. Os parâmetros analíticos avaliados foram satisfatõrios, apresentando linearidade de 100 a 4000 ng L -1, recuperaç ões para os quatro níveis de fortificação (Limite de Quantificação do Método, 200, 1000 e 2000 ng L-1) entre 62 e 107% com desvio padrão relativo menor que 14%. Os limites de quantificação foram encontrados na faixa de ng L-1, variando entre 10 e 100 ng L-1. O método proposto foi aplicado para a determinação dos quatro filtros UV em amostras de águas naturais. This study describes the development and optimization of a solid-phase extraction (SPE) method for analysis of ultraviolet (UV) filters, benzophenone-3 (BP-3), ethylhexyl methoxycinnamate (EHMC), ethylhexyl salicylate (ES) and octocrylene (OC), in environmental matrices. A 25-1 fractional factorial design (FFD) was used to evaluate the significant variables for the extraction method. The optimized experimental conditions determined from the statistical evaluation were: breakthrough volume of 500 mL, eluent of ethyl acetate, wash solvent of methanol (10% in water, v/v), eluent volume of 3 × 2 mL and pH 3. The evaluated analytical parameters were satisfactory for the analytes and showed linearity between 100 and 4000 ng L-1, recoveries for four fortification levels (Method Quantification Limit, 200, 1000 and 2000 ng L-1) were between 62 and 107% with relative standard deviations less than 14%. Limits of quantification were in the ng L-1 range and were between 10 and 100 ng L-1. The proposed method was used to analyze four UV filters in natural water samples. ©2013 Sociedade Brasileira de Química.en
dc.description.affiliationDepartment of Analytical Chemistry Institute of Chemistry São Paulo State University (UNESP), 14801-970 Araraquara-SP
dc.description.affiliationUnespDepartment of Analytical Chemistry Institute of Chemistry São Paulo State University (UNESP), 14801-970 Araraquara-SP
dc.format.extent1433-1441
dc.identifierhttp://dx.doi.org/10.5935/0103-5053.20130182
dc.identifier.citationJournal of the Brazilian Chemical Society, v. 24, n. 9, p. 1433-1441, 2013.
dc.identifier.doi10.5935/0103-5053.20130182
dc.identifier.file2-s2.0-84883777651.pdf
dc.identifier.issn0103-5053
dc.identifier.issn1678-4790
dc.identifier.lattes2543372149131902
dc.identifier.scopus2-s2.0-84883777651
dc.identifier.urihttp://hdl.handle.net/11449/76482
dc.identifier.wosWOS:000324933300007
dc.language.isoeng
dc.relation.ispartofJournal of the Brazilian Chemical Society
dc.relation.ispartofjcr1.444
dc.relation.ispartofsjr0,357
dc.relation.ispartofsjr0,357
dc.rights.accessRightsAcesso abertopt
dc.sourceScopus
dc.subjectExperimental design
dc.subjectGC-MS/MS
dc.subjectSolid-phase extraction
dc.subjectUV filters
dc.titleUV filters in water samples: Experimental design on the SPE optimization followed by GC-MS/MS analysisen
dc.typeArtigopt
dcterms.licensehttp://jbcs.sbq.org.br/copyright
dspace.entity.typePublication
relation.isOrgUnitOfPublicationbc74a1ce-4c4c-4dad-8378-83962d76c4fd
relation.isOrgUnitOfPublication.latestForDiscoverybc74a1ce-4c4c-4dad-8378-83962d76c4fd
unesp.author.lattes2543372149131902
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-84883777651.pdf
Tamanho:
1.67 MB
Formato:
Adobe Portable Document Format