Logo do repositório

Short- and Long-term Evaluation of Dentin-Resin Interfaces Formed by Etch-and-Rinse Adhesives on Plasma-treated Dentin

dc.contributor.authorHirata, Ronaldo
dc.contributor.authorSampaio, Camila
dc.contributor.authorMachado, Lucas S. [UNESP]
dc.contributor.authorCoelho, Paulo G.
dc.contributor.authorThompson, Van P.
dc.contributor.authorDuarte, Simone
dc.contributor.authorAlmeida Ayres, Ana Paula
dc.contributor.authorGiannini, Marcelo
dc.contributor.institutionNYU
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionKings Coll London Inst
dc.date.accessioned2018-11-26T16:48:19Z
dc.date.available2018-11-26T16:48:19Z
dc.date.issued2016-01-01
dc.description.abstractPurpose: To investigate the influence of atmospheric pressure plasma (APP) treatment on the microtensile dentin bond strength of two etch-and-rinse adhesive systems, after one week and one year of water storage, and additionally to observe the micromorphology of resin/dentin interfaces under scanning electronic microscopy (SEM). Materials and Methods: The occlusal enamel was removed from third human molars to expose a flat dentin surface. The teeth were then randomly divided into six groups (n = 7), according to two adhesives (Optibond FL and XP-Bond) and three APP treatments (untreated dentin [control], APP application before or after acid etching). After performing the composite resin buildup on bonded dentin, the teeth were sectioned perpendicularly to the bonded interface to obtain beam-shaped specimens (cross-sectional area of similar to 0.9 mm(2)). The specimens were tested in tension until failure after one week and one year of water storage (1.0 mm/min rate). Bond strength data were analyzed by three-way ANOVA and Tukey's post-hoc test (alpha = 0.05%). Bonded beam specimens from each tooth were also prepared for interfacial SEM investigation. Results: At one week, APP treatment applied after acid etching increased the dentin bond strength for XP Bond, while no effect was observed for Optibond FL. After one year, the bond strength of XP Bond decreased in groups where APP was applied after etching. The evaluation time did not influence the bond strength for Optibond FL. Conclusion: One-year evaluation did not show any sign of degradation of interfacial structures in any group. Application of APP to etched dentin combined with a two-step etch-and-rinse adhesive significantly increased bond strength at one week, but the effect was not stable after one year and was adhesive dependent.en
dc.description.affiliationNYU, Coll Dent, Dept Biomat & Biomimet, New York, NY USA
dc.description.affiliationUniv Estadual Campinas, Dept Restorat Dent, Piracicaba Dent Sch, Piracicaba, SP, Brazil
dc.description.affiliationSao Paulo State Univ, Aracatuba Dent Sch, Dept Restorat Dent, Aracatuba, SP, Brazil
dc.description.affiliationKings Coll London Inst, Dept Biomat Biomimet & Biophoton, London, England
dc.description.affiliationNYU, Coll Dent, Dept Basic Sci, New York, NY USA
dc.description.affiliationUnespSao Paulo State Univ, Aracatuba Dent Sch, Dept Restorat Dent, Aracatuba, SP, Brazil
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipIdCAPES: 1777-2014
dc.description.sponsorshipIdFAPESP: 2013/15952-7
dc.description.sponsorshipIdCNPq: 307217-2014-0
dc.format.extent215-222
dc.identifierhttp://dx.doi.org/10.3290/j.jad.a36134
dc.identifier.citationJournal Of Adhesive Dentistry. Hanover Park: Quintessence Publishing Co Inc, v. 18, n. 3, p. 215-222, 2016.
dc.identifier.doi10.3290/j.jad.a36134
dc.identifier.issn1461-5185
dc.identifier.urihttp://hdl.handle.net/11449/161706
dc.identifier.wosWOS:000379355300005
dc.language.isoeng
dc.publisherQuintessence Publishing Co Inc
dc.relation.ispartofJournal Of Adhesive Dentistry
dc.relation.ispartofsjr0,839
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectplasma
dc.subjectmicrotensile
dc.subjectdentin adhesion
dc.titleShort- and Long-term Evaluation of Dentin-Resin Interfaces Formed by Etch-and-Rinse Adhesives on Plasma-treated Dentinen
dc.typeArtigopt
dcterms.rightsHolderQuintessence Publishing Co Inc
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentOdontologia Restauradora - FOApt

Arquivos