Logotipo do repositório
 

Publicação:
Exploring CBCT-Based DICOM Files. A Systematic Review on the Properties of Images Used to Evaluate Maxillofacial Bone Grafts

dc.contributor.authorSpin-Neto, Rubens [UNESP]
dc.contributor.authorMarcantonio, Elcio [UNESP]
dc.contributor.authorGotfredsen, Erik
dc.contributor.authorWenzel, Ann
dc.contributor.institutionAarhus University (AU)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:31:57Z
dc.date.accessioned2014-05-20T13:45:28Z
dc.date.available2013-09-30T18:31:57Z
dc.date.available2014-05-20T13:45:28Z
dc.date.issued2011-12-01
dc.description.abstractPrevious studies suggests that cone beam computerized tomography (CBCT) images could provide reliable information regarding the fate of bone grafts in the maxillofacial region, but no systematic information regarding the standardization of CBCT settings and properties is available, i.e., there is a lack of information on how the images were generated, exported, and analyzed when bone grafts were evaluated. The aim of this study was to (1) do a systematic review on which type of CBCT-based DICOM images have been used for the evaluation of the fate of bone grafts in humans and (2) use a software suggested in the literature to test DICOM-based data sets, exemplifying the effect of variation in selected parameters (windowing/contrast control, plane definition, slice thickness, and number of measured slices) on the final image characteristics. The results from review identified three publications that used CBCT to evaluate maxillofacial bone grafts in humans, and in which the methodology/results comprised at least one of the expected outcomes (image acquisition protocol, image reconstruction, and image generation information). The experimental shows how the influence of information that was missing in the retrieved papers, can influence the reproducibility and the validity of image measurements. Although the use of CBCT-based images for the evaluation of bone grafts in humans has become more common, this does not reflect on a better standardization of the developed studies. Parameters regarding image acquisition and reconstruction, while important, are not addressed in the proper way in the literature, compromising the reproducibility and scientific impact of the studies.en
dc.description.affiliationAarhus Univ, Dept Oral Radiol, Sch Dent, DK-8000 Aarhus C, Denmark
dc.description.affiliationUNESP Univ Estadual Paulista, Dept Periodontol, Araraquara Dent Sch, São Paulo, Brazil
dc.description.affiliationUnespUNESP Univ Estadual Paulista, Dept Periodontol, Araraquara Dent Sch, São Paulo, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipIdFAPESP: 08/09207-9
dc.format.extent959-966
dc.identifierhttp://dx.doi.org/10.1007/s10278-011-9377-y
dc.identifier.citationJournal of Digital Imaging. New York: Springer, v. 24, n. 6, p. 959-966, 2011.
dc.identifier.doi10.1007/s10278-011-9377-y
dc.identifier.issn0897-1889
dc.identifier.urihttp://hdl.handle.net/11449/15999
dc.identifier.wosWOS:000296882500002
dc.language.isoeng
dc.publisherSpringer
dc.relation.ispartofJournal of Digital Imaging
dc.relation.ispartofjcr1.536
dc.relation.ispartofsjr0,540
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectCBCTen
dc.subjectBone graften
dc.subjectWindowingen
dc.subjectPlane definitionen
dc.subjectSlice thicknessen
dc.titleExploring CBCT-Based DICOM Files. A Systematic Review on the Properties of Images Used to Evaluate Maxillofacial Bone Graftsen
dc.typeArtigo
dcterms.licensehttp://www.springer.com/open+access/authors+rights?SGWID=0-176704-12-683201-0
dcterms.rightsHolderSpringer
dspace.entity.typePublication
unesp.author.orcid0000-0002-9660-4524[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: