Logotipo do repositório
 

Publicação:
Distinct Sources of a Bovine Blastocyst Digital Image Do not Produce the Same Classification by a Previously Trained Software Using Artificial Neural Network

dc.contributor.authorGuilherme, Vitória Bertogna [UNESP]
dc.contributor.authorPronunciate, Micheli [UNESP]
dc.contributor.authordos Santos, Priscila Helena [UNESP]
dc.contributor.authorde Souza Ciniciato, Diego [UNESP]
dc.contributor.authorTakahashi, Maria Beatriz [UNESP]
dc.contributor.authorRocha, José Celso [UNESP]
dc.contributor.authorGouveia Nogueira, Marcelo Fábio [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2020-12-12T02:30:41Z
dc.date.available2020-12-12T02:30:41Z
dc.date.issued2019-01-01
dc.description.abstractWe develop an online graphical and intuitive interface connected to a server aiming to facilitate access to professionals worldwide that face problems with bovine blastocysts classification. The interface Blasto3Q (3Q is referred to the three qualities of the blastocyst grading) contains a description of 24 variables that are extracted from the image of the blastocyst and analyzed by three Artificial Neural Networks (ANNs) that classifies the same loaded image. The same embryo (i.e., the biological specimen) was submitted to digital image capture by the control group (inverted microscope with 40x of magnification) and to experimental group (stereomicroscope with maximum of magnification plus 4x zoom from the cell phone). The 36 images obtained from control and experimental groups were uploaded on the Blasto3Q. Each image from both sources was evaluated for segmentation and submitted (only if it could be properly or partially segmented) to the quality grade classification by the three ANNs of the Blasto3Q program. In the group control, all the images were properly segmented, whereas 38.9% (07/18) and 61.1% (11/18) of the images from the experimental group, respectively could not be segmented or were partially segmented. The percentage of agreement was calculated when the same blastocyst was evaluated by the same ANN from the two sources (control and experimental groups). On the 54 potential evaluations of the three ANNs (i.e., 18 images been evaluated by the three networks) from the experimental group only 22.2% agreed with evaluations of the control (12/54). Of the remaining 42 disagreed evaluations from experimental group, 21 were unable to be performed and 21 were wrongly processed when compared with control evaluation.en
dc.description.affiliationLaboratório de Micromanipulação Embrionária School of Sciences and Languages Universidade Estadual Paulista (Unesp), Av. Dom Antonio 2100
dc.description.affiliationLaboratório Multiusuário FitoFarmaTec Institute of Biosciences Unesp, Rubião Jr.
dc.description.affiliationLaboratório de Matemática Aplicada School of Sciences and Languages Unesp, Av. Dom Antonio 2100
dc.description.affiliationUnespLaboratório de Micromanipulação Embrionária School of Sciences and Languages Universidade Estadual Paulista (Unesp), Av. Dom Antonio 2100
dc.description.affiliationUnespLaboratório Multiusuário FitoFarmaTec Institute of Biosciences Unesp, Rubião Jr.
dc.description.affiliationUnespLaboratório de Matemática Aplicada School of Sciences and Languages Unesp, Av. Dom Antonio 2100
dc.format.extent139-153
dc.identifierhttp://dx.doi.org/10.1007/978-3-030-32965-5_8
dc.identifier.citationCommunications in Computer and Information Science, v. 654, p. 139-153.
dc.identifier.doi10.1007/978-3-030-32965-5_8
dc.identifier.issn1865-0937
dc.identifier.issn1865-0929
dc.identifier.scopus2-s2.0-85075808366
dc.identifier.urihttp://hdl.handle.net/11449/201365
dc.language.isoeng
dc.relation.ispartofCommunications in Computer and Information Science
dc.sourceScopus
dc.titleDistinct Sources of a Bovine Blastocyst Digital Image Do not Produce the Same Classification by a Previously Trained Software Using Artificial Neural Networken
dc.typeTrabalho apresentado em evento
dspace.entity.typePublication
unesp.departmentCiências Biológicas - FCLASpt

Arquivos