Atenção!


O atendimento às questões referentes ao Repositório Institucional será interrompido entre os dias 20 de dezembro de 2025 a 4 de janeiro de 2026.

Pedimos a sua compreensão e aproveitamos para desejar boas festas!

Logo do repositório

Influence of number and position of porcelain specimens in the furnace on flexural strength and translucency

dc.contributor.authorMachado, Pablo Soares
dc.contributor.authorCamponogara, Jeanni Gonçalves
dc.contributor.authorda Silva Rodrigues, Camila [UNESP]
dc.contributor.authorJacques, Letícia Borges
dc.contributor.authorValandro, Luiz Felipe
dc.contributor.authorRippe, Marília Pivetta
dc.contributor.institutionFederal University of Santa Maria
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2025-04-29T20:14:23Z
dc.date.issued2022-01-01
dc.description.abstractAim: The aim of this study was to investigate the influence of the quantity and positioning of feldspathic ceramic specimens inside the furnace on their flexural strength and translucency. The tested hypotheses were that the arrangement of specimens in the furnance would not influence 1) the translucency or 2) the biaxial strength of the porcelain. Methods: Ninety porcelain specimens were made (1.2 mm thickness and 13.5 mm diameter) and assigned into two main groups (n=15): G1 group - 15 firing cycles containing only one specimen each, always at the center of the refractory; and G5 group - 15 firing cycles containing five specimen each, where one specimen was at the center of the refractory and four specimens positioned equidistantly on the periphery. The translucency test was performed using a spectrophotometer, followed by the flexural strength test, according to ISO 6872:2015. T-student test was performed for both the mechanical and optical obtained data. Results: The flexural strength of the porcelain was not affected by the positioning (center x periphery) of the specimens inside the furnace (p =0.08), but the translucency was affected (periphery > center; p =0.009). Regarding to the number of feldspathic ceramic specimens, the biaxial flexural strength was affected (p =0.025), as well as the translucency (p <0.05). Conclusion: A higher quantity of feldspathic ceramic specimens for each firing cycle decreased its biaxial flexural strength and translucency. Also, specimens positioned at the center of the refractory became less translucent than those positioned at the periphery.en
dc.description.affiliationPost Graduate Program in Dental Science Federal University of Santa Maria, Rio Grande do Sul State
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Institute of Science and Technology São Paulo State University, São Paulo State
dc.description.affiliationProsthodontics Unit Faculty of Odontology Federal University of Santa Maria, Rio Grande do Sul State
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Institute of Science and Technology São Paulo State University, São Paulo State
dc.identifierhttp://dx.doi.org/10.20396/BJOS.V22I00.8671377
dc.identifier.citationBrazilian Journal of Oral Sciences, v. 22.
dc.identifier.doi10.20396/BJOS.V22I00.8671377
dc.identifier.issn1677-3225
dc.identifier.issn1677-3217
dc.identifier.scopus2-s2.0-85182236195
dc.identifier.urihttps://hdl.handle.net/11449/309099
dc.language.isoeng
dc.relation.ispartofBrazilian Journal of Oral Sciences
dc.sourceScopus
dc.subjectDental porcelain
dc.subjectFlexural strength
dc.subjectOptical phenomena
dc.titleInfluence of number and position of porcelain specimens in the furnace on flexural strength and translucencyen
dc.typeArtigopt
dspace.entity.typePublication

Arquivos

Coleções