Logo do repositório
 

Análise comparativa entre implantes de titânio e cerâmica policristalina, na sobrevivencia em fadiga e comportamento biomecânico

dc.contributor.advisorBottino, Marco Antonio [UNESP]
dc.contributor.authorMatos, Jefferson David Melo de [UNESP]
dc.contributor.coadvisorVasconcelos, John Eversong Lucena
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)pt
dc.date.accessioned2025-05-27T12:24:19Z
dc.date.issued2024-02-23
dc.description.abstractO objetivo do presente estudo foi avaliar o comportamento biomecânico e a resistência à fadiga de implantes unitários em dois diferentes grupos: implantes de titânio com coroas de zircônia e implantes de zircônia com coroas de zircônia. Inicialmente, a microestrutura superficial dos implantes foi caracterizada por meio das análises de RAMAN e DRX. Para os ensaios de fadiga foram utilizados 40 implantes, sendo 20 confeccionados em titânio comercialmente puro (TZ) e 20 confeccionados em zircônia (ZZ). Os implantes apresentavam o diâmetro de 4,1 mm com comprimento de 10 mm. Aos implantes foram parafusados pilares protéticos de titânio (Purebase e Variobase) com desenho cônico de 8° e encaixe por fricção interna, instalados com torque de 35 N.cm com o auxílio de um torquímetro digital. Os torques foram confirmados após 10 minutos da instalação, no início e ao término do teste de fadiga. Por meio da tecnologia CAD/CAM foram usinadas as coroas em zircônia, cimentadas sobre os pilares protéticos. No ensaio de carga máxima para fratura, o grupo ZZ apresentou média de 1123,73 ± 153,61 kgf, enquanto a média do grupo TZ foi de 818,67 ± 42,41; sem diferença estatística entre eles. Os espécimes passaram pelo teste de sobrevivência em fadiga (2.000.000 ciclos na frequência de 2 Hz com aplicador de aço inoxidável de 1,6 mm de diâmetro), conforme parâmetros descritos na ISO 14801:2016 e não apresentaram falhas. Em seguida, os espécimes foram submetidos ao teste de sobrevivência stepwise sem que apresentassem diferença significativa em relação ao número de ciclos para falha. No entanto, em relação à carga aplicada, o grupo ZZ mostrou-se mais resistente que o grupo TZ. Dados colhidos através de parâmetros obtidos no teste stepwise, com aplicação de carga de 200 N em 30º, simulando a condição do teste de fadiga. O comportamento biomecânico do conjunto composto por implante, pilar protético, parafuso protético e coroa monolítica foram semelhantes nos grupos ZZ e TZ. Concluiu-se que a estabilidade estrutural e a resistência mecânica do conjunto coroa/implante foram semelhantes entre os implantes de zircônia e titânio. Os dois implantes se apresentaram capazes de suportar cargas oclusais compatíveis com a região anterior.pt
dc.description.abstractThe objective of the present study was to evaluate the biomechanical behavior and fatigue resistance of single implants in two different groups: titanium implants with zirconia crowns and zirconia implants with zirconia crowns. Initially, the surface microstructure of the implants was characterized using RAMAN and XRD analyses. For fatigue tests, 40 implants were used, 20 made from commercially pure titanium (TZ) and 20 made from zirconia (ZZ). The implants had a diameter of 4.1 mm and a length of 10 mm. Titanium prosthetic pillars (Purebase and Variobase) with an 8° conical design and internal friction fit were screwed to the implants, and installed with a torque of 35 N.cm with the aid of a digital torque meter. The torques were confirmed 10 minutes after installation, at the beginning and end of the fatigue test. Using CAD/CAM technology, the zirconia crowns were machined and cemented onto the prosthetic abutments. In the maximum fracture load test, the ZZ group presented an average of 1123.73 ± 153.61 kgf, while the TZ group's average was 818.67 ± 42.41; with no statistical difference between them. The specimens passed the fatigue survival test (2,000,000 cycles at a frequency of 2 Hz with a 1.6 mm diameter stainless steel applicator), according to parameters described in ISO 14801:2016 and showed no failures. Then, the specimens were subjected to the stepwise survival test without showing a significant difference concerning the number of cycles to failure. However, about the applied load, the ZZ group proved to be more resistant than the TZ group. Data was collected through parameters obtained in the stepwise test, applying a load of 200 N at 30º, simulating the fatigue test condition. The biomechanical behavior of the set consisting of implant, prosthetic abutment, prosthetic screw, and monolithic crown were similar in the ZZ and TZ groups. It was concluded that the structural stability and mechanical resistance of the crown/implant set were similar between zirconia and titanium implants. Both implants were capable of supporting occlusal loads compatible with the anterior region.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdProcesso nº 2019/24903-6, 2021/11499-2.
dc.identifier.capes33004145070P8
dc.identifier.latteshttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K8138963Z3
dc.identifier.orcid0000-0003-4507-0785
dc.identifier.urihttps://hdl.handle.net/11449/310708
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso abertopt
dc.subjectCoroaspt
dc.subjectDental materialsen
dc.subjectMateriais dentáriospt
dc.subjectDental implantsen
dc.subjectImplantes dentáriospt
dc.subjectCrownsen
dc.titleAnálise comparativa entre implantes de titânio e cerâmica policristalina, na sobrevivencia em fadiga e comportamento biomecânicopt
dc.title.alternativeComparative analysis between titanium implants and polycrystalline ceramics in survival on fatigue and biomechanical behavioren
dc.typeTese de doutoradopt
dspace.entity.typePublication
relation.isAuthorOfPublicationbb2b80a4-8cc3-4b04-b5c4-40cf1c9f3a5d
relation.isAuthorOfPublication.latestForDiscoverybb2b80a4-8cc3-4b04-b5c4-40cf1c9f3a5d
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.embargoOnlinept
unesp.examinationboard.typeBanca públicapt
unesp.graduateProgramCiências Aplicadas à Saúde Bucal - ICTpt
unesp.knowledgeAreaBiomateriaispt
unesp.researchAreaBioatividade em materiais restauradores e comportamento biomecânico de restaurações indiretas e implantespt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
matos_jdm_dr_sjc.pdf
Tamanho:
3.96 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
2.14 KB
Formato:
Item-specific license agreed upon to submission
Descrição: