Publicação:
Phantom development for radiographic image optimization of chest, skull and pelvis examination for nonstandard patient

dc.contributor.authorMiranda, Diana Rodrigues de Pina [UNESP]
dc.contributor.authorDuarte, S. B.
dc.contributor.authorNetto, T. Ghilardi
dc.contributor.authorMorceli, J. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionCentro Brasileiro de Pesquisas Físicas (CBPF)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2014-05-20T13:34:33Z
dc.date.available2014-05-20T13:34:33Z
dc.date.issued2009-01-01
dc.description.abstractThe construction of the adapted patient equivalent phantom (APEP) to simulate the X-ray scattering and absorption by chest, skull and pelvis of nonstandard patient in conventional radiographic equipment is presented. This APEP system is associated to the pre-existing realistic-analytic phantom (RAP) [Pina, D.R., Duarte, S.B., Ghilardi Netto, T., Trad, C. S., Brochi, M.A.C., Oliveira, S.C. de, 2004. Optimization of standard patient radiographic images for chest, skull and pelvis exams in conventional X-ray equipment. Phys. Med. Biol. 49, N215-N226] forming the coupled phantom (RAP-APEP), which is used to establish an optimization process of radiographic images of chest, skull and pelvis for nonstandard patients. A chart of the optimized radiographic technique is established covering a wide range of nonstandard patient thickness, and offering a dose reduction in comparison with those techniques currently used. Different validation processes were applied to confirm the improving of the radiographic image quality when techniques of the established chart are used. (C) 2008 Elsevier Ltd. All rights reserved.en
dc.description.affiliationUniv Estadual Paulista, Fac Med, Dept Doencas Trop & Diagnost Imagem, BR-18618970 São Paulo, Brazil
dc.description.affiliationCBPF MCT, BR-22290180 Rio de Janeiro, Brazil
dc.description.affiliationHosp Clin Fac Med Ribeirao Preto, Ctr Ciencias Imagem & Fis Med, BR-14048900 São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Fac Med, Dept Doencas Trop & Diagnost Imagem, BR-18618970 São Paulo, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipFundação de Apoio ao Ensino, Pesquisa e Assistência do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da USP (FAEPA)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.format.extent61-69
dc.identifierhttp://dx.doi.org/10.1016/j.apradiso.2008.07.018
dc.identifier.citationApplied Radiation and Isotopes. Oxford: Pergamon-Elsevier B.V. Ltd, v. 67, n. 1, p. 61-69, 2009.
dc.identifier.doi10.1016/j.apradiso.2008.07.018
dc.identifier.issn0969-8043
dc.identifier.urihttp://hdl.handle.net/11449/11861
dc.identifier.wosWOS:000261858700012
dc.language.isoeng
dc.publisherPergamon-Elsevier B.V. Ltd
dc.relation.ispartofApplied Radiation and Isotopes
dc.relation.ispartofjcr1.123
dc.relation.ispartofsjr0,528
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectRadiographic techniqueen
dc.subjectQuality imageen
dc.subjectPhantomen
dc.subjectNonstandard patienten
dc.subjectReduction doseen
dc.titlePhantom development for radiographic image optimization of chest, skull and pelvis examination for nonstandard patienten
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderPergamon-Elsevier B.V. Ltd
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt
unesp.departmentDoenças Tropicais e Diagnósticos por Imagem - FMBpt

Arquivos

Licença do Pacote