Publicação: Phantom development for radiographic image optimization of chest, skull and pelvis examination for nonstandard patient
dc.contributor.author | Miranda, Diana Rodrigues de Pina [UNESP] | |
dc.contributor.author | Duarte, S. B. | |
dc.contributor.author | Netto, T. Ghilardi | |
dc.contributor.author | Morceli, J. [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Centro Brasileiro de Pesquisas Físicas (CBPF) | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.date.accessioned | 2014-05-20T13:34:33Z | |
dc.date.available | 2014-05-20T13:34:33Z | |
dc.date.issued | 2009-01-01 | |
dc.description.abstract | The construction of the adapted patient equivalent phantom (APEP) to simulate the X-ray scattering and absorption by chest, skull and pelvis of nonstandard patient in conventional radiographic equipment is presented. This APEP system is associated to the pre-existing realistic-analytic phantom (RAP) [Pina, D.R., Duarte, S.B., Ghilardi Netto, T., Trad, C. S., Brochi, M.A.C., Oliveira, S.C. de, 2004. Optimization of standard patient radiographic images for chest, skull and pelvis exams in conventional X-ray equipment. Phys. Med. Biol. 49, N215-N226] forming the coupled phantom (RAP-APEP), which is used to establish an optimization process of radiographic images of chest, skull and pelvis for nonstandard patients. A chart of the optimized radiographic technique is established covering a wide range of nonstandard patient thickness, and offering a dose reduction in comparison with those techniques currently used. Different validation processes were applied to confirm the improving of the radiographic image quality when techniques of the established chart are used. (C) 2008 Elsevier Ltd. All rights reserved. | en |
dc.description.affiliation | Univ Estadual Paulista, Fac Med, Dept Doencas Trop & Diagnost Imagem, BR-18618970 São Paulo, Brazil | |
dc.description.affiliation | CBPF MCT, BR-22290180 Rio de Janeiro, Brazil | |
dc.description.affiliation | Hosp Clin Fac Med Ribeirao Preto, Ctr Ciencias Imagem & Fis Med, BR-14048900 São Paulo, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Fac Med, Dept Doencas Trop & Diagnost Imagem, BR-18618970 São Paulo, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | Fundação de Apoio ao Ensino, Pesquisa e Assistência do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da USP (FAEPA) | |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.format.extent | 61-69 | |
dc.identifier | http://dx.doi.org/10.1016/j.apradiso.2008.07.018 | |
dc.identifier.citation | Applied Radiation and Isotopes. Oxford: Pergamon-Elsevier B.V. Ltd, v. 67, n. 1, p. 61-69, 2009. | |
dc.identifier.doi | 10.1016/j.apradiso.2008.07.018 | |
dc.identifier.issn | 0969-8043 | |
dc.identifier.uri | http://hdl.handle.net/11449/11861 | |
dc.identifier.wos | WOS:000261858700012 | |
dc.language.iso | eng | |
dc.publisher | Pergamon-Elsevier B.V. Ltd | |
dc.relation.ispartof | Applied Radiation and Isotopes | |
dc.relation.ispartofjcr | 1.123 | |
dc.relation.ispartofsjr | 0,528 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | Radiographic technique | en |
dc.subject | Quality image | en |
dc.subject | Phantom | en |
dc.subject | Nonstandard patient | en |
dc.subject | Reduction dose | en |
dc.title | Phantom development for radiographic image optimization of chest, skull and pelvis examination for nonstandard patient | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dcterms.rightsHolder | Pergamon-Elsevier B.V. Ltd | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatu | pt |
unesp.department | Doenças Tropicais e Diagnósticos por Imagem - FMB | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: