Logotipo do repositório
 

Publicação:
Standard dilution analysis in flow system: Sodium determination by flame atomic emission spectrometry

dc.contributor.authorFortunato, Felipe M. [UNESP]
dc.contributor.authorBechlin, Marcos A. [UNESP]
dc.contributor.authorGomes Neto, José A. [UNESP]
dc.contributor.authorVirgilio, Alex
dc.contributor.authorDonati, George L.
dc.contributor.authorJones, Bradley T.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal de São Carlos (UFSCar)
dc.contributor.institutionWake Forest University, Department of Chemistry
dc.date.accessioned2018-12-11T16:39:50Z
dc.date.available2018-12-11T16:39:50Z
dc.date.issued2016-01-01
dc.description.abstractStandard dilution analysis (SDA) is a new calibration method that combines the principles of internal standardization and standard additions. The current work evaluated the feasibility of SDA automation using a flow-injection system (FIA). The FIA-SDA system was applied to sodium determination in biodiesel samples and certified reference materials (CRMs) by flame atomic emission spectrometry (FAES). Lithium was employed as internal standard in all determinations. The results for Na determination in five CRMs using FIA-SDA were in agreement with certified values at the 95% confidence level (t-test). For comparison purposes, Na was also determined by the traditional methods of external standard (ES), standard additions (SA) and internal standardization (IS). Recoveries showed increased accuracy following the sequence ES (181-202%). <. IS (67-72%). <. SA (111-126%). <. FIA-SDA (94-98%). FIA-SDA provided more accurate and precise results than ES, SA and IS for Na determination in biodiesel and CRMs by FAES.en
dc.description.affiliationUNESP - Univ. Estadual Paulista, Instituto de Química, P.O. Box 355
dc.description.affiliationUniv. Federal de São Carlos, Departamento de Química
dc.description.affiliationWake Forest University, Department of Chemistry, Salem Hall Box 7486
dc.description.affiliationUnespUNESP - Univ. Estadual Paulista, Instituto de Química, P.O. Box 355
dc.format.extent662-667
dc.identifierhttp://dx.doi.org/10.1016/j.microc.2015.10.019
dc.identifier.citationMicrochemical Journal, v. 124, p. 662-667.
dc.identifier.doi10.1016/j.microc.2015.10.019
dc.identifier.file2-s2.0-84946235380.pdf
dc.identifier.issn0026-265X
dc.identifier.scopus2-s2.0-84946235380
dc.identifier.urihttp://hdl.handle.net/11449/168123
dc.language.isoeng
dc.relation.ispartofMicrochemical Journal
dc.rights.accessRightsAcesso abertopt
dc.sourceScopus
dc.subjectCalibration
dc.subjectFlow-injection analysis
dc.subjectStandard dilution analysis
dc.titleStandard dilution analysis in flow system: Sodium determination by flame atomic emission spectrometryen
dc.typeArtigopt
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-84946235380.pdf
Tamanho:
554.22 KB
Formato:
Adobe Portable Document Format
Descrição: