Avaliação da rugosidade superficial, módulo elástico, microdureza e resistência à flexão de uma resina temporária de longa duração
| dc.contributor.advisor | Silva, João Maurício Ferraz da [UNESP] | |
| dc.contributor.author | Castro, Danielle Cristinne Anjos de [UNESP] | |
| dc.contributor.coadvisor | Silva, Clarisse Maria Luiz | |
| dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
| dc.date.accessioned | 2025-11-25T14:39:49Z | |
| dc.date.issued | 2025-10-22 | |
| dc.description.abstract | Objetivo: O objetivo deste estudo foi avaliar o comportamento mecânico e a qualidade de superfície de uma resina de impressão 3D comparando com uma resina fresada em CAD/CAM. Material e Métodos: Foram utilizadas duas resinas: resina de impressão 3D (V-Print c&b temp, VOCO, Alemanha) e compósito nanohíbrido CAD/CAM (Grandio Bloc, VOCO, Alemanha). As amostras da resina impressa foram desenhadas no software Rhinoceros e fabricadas em impressora DLP (ASIGA, Austrália). As amostras da resina fresada em disco foram obtidas através de um disco para fresagem em uma cortadora de espécimes circulares e as barras foram cortadas com um disco de carborundum e peça reta. A rugosidade superficial (n=60) foi medida com rugosímetro de contato, registrando os parâmetros Ra e Rz. A microdureza Knoop (n=8) foi avaliada em testador digital. O módulo elástico (n=10) foi determinado pela técnica de excitação por impulso, utilizando barras de 40×15×2 mm. A resistência à flexão foi testada em barras de 25×2×2 mm, pela flexão de três pontos até a fratura. Resultados: A rugosidade superficial não apresentou diferença estatisticamente significativa entre os grupos (p>0,5). Na microdureza Knoop, os grupos apresentaram diferença estatística entre si (p<0,001), sendo a dureza da resina fresada maior. Módulo de elasticidade foi superior para a resina fresada (24,70 ± 2,29 GPa) em comparação à impressa (5,51 ± 0,45 GPa). Na resistência à flexão, resina impressa atingiu média de 124 ± 12,8 MPa. Conclusão: A resina impressa apresentou valores inferiores em comparação ao compósito nanohíbrido fresado, entretanto, manteve desempenho dentro de parâmetros clinicamente aceitáveis. | pt |
| dc.description.abstract | Objective: The objective of this study was to evaluate the mechanical behavior and surface quality of a 3D-printed resin compared to a milled CAD/CAM composite resin. Materials and Methods: Two resins were used: a 3D-printed resin (V-Print c&b temp, VOCO, Germany) and a nanohybrid CAD/CAM composite (Grandio Bloc, VOCO, Germany). The printed resin samples were designed using Rhinoceros software and manufactured with a DLP printer (ASIGA, Australia). The milled resin discs were obtained from CAD/CAM blocks using a specimen-cutting machine, and the bars were sectioned with a carborundum disc and straight handpiece. Surface roughness (n=60) was measured with a contact profilometer, recording the Ra and Rz parameters. Knoop microhardness (n=8) was evaluated using a digital hardness tester. The elastic modulus (n=10) was determined by the impulse excitation technique, using rectangular bars (40×15×2 mm). Flexural strength was tested on bars (25×2×2 mm) using a threepoint bending test until fracture. Results: Surface roughness showed no statistically significant difference between the groups (p > 0.05). For Knoop microhardness, a significant difference was found between groups (p < 0.001), with the milled resin presenting higher hardness values. The elastic modulus was higher for the milled resin (24.70 ± 2.29 GPa) compared to the printed one (5.51 ± 0.45 GPa). The flexural strength of the printed resin averaged 124 ± 12.8 MPa. Conclusion: The 3D-printed resin exhibited lower mechanical properties compared to the milled nanohybrid composite; however, it maintained clinically acceptable performance | en |
| dc.identifier.uri | https://hdl.handle.net/11449/315534 | |
| dc.language.iso | por | |
| dc.publisher | Universidade Estadual Paulista (Unesp) | |
| dc.rights.accessRights | Acesso restrito | pt |
| dc.subject | Impressão tridimensional | pt |
| dc.subject | Printing, three-dimensional | en |
| dc.subject | Desenho assistido por computador | pt |
| dc.subject | Computer-aided design | en |
| dc.subject | Materiais dentários | pt |
| dc.subject | Dental materials | en |
| dc.title | Avaliação da rugosidade superficial, módulo elástico, microdureza e resistência à flexão de uma resina temporária de longa duração | pt |
| dc.title.alternative | Evaluation of surface roughness, elastic modulus, microhardness, and flexural strength of a long-term temporary resin | en |
| dc.type | Trabalho de conclusão de curso | pt |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 5f1a18fa-5b0b-456c-9df5-2a94ddabca95 | |
| relation.isAuthorOfPublication.latestForDiscovery | 5f1a18fa-5b0b-456c-9df5-2a94ddabca95 | |
| unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campos | pt |
| unesp.examinationboard.type | Banca pública | pt |
| unesp.undergraduate | São José dos Campos - ICT - Odontologia | pt |
Arquivos
Pacote original
1 - 1 de 1
Carregando...
- Nome:
- castro_dca_tcc_sjc.pdf
- Tamanho:
- 962.3 KB
- Formato:
- Adobe Portable Document Format
Licença do pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 2.14 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- autorização_castro_dca_tcc_sjc.pdf
- Tamanho:
- 131.63 KB
- Formato:
- Adobe Portable Document Format
- Descrição:
