Logo do repositório

Avaliação da rugosidade superficial, módulo elástico, microdureza e resistência à flexão de uma resina temporária de longa duração

dc.contributor.advisorSilva, João Maurício Ferraz da [UNESP]
dc.contributor.authorCastro, Danielle Cristinne Anjos de [UNESP]
dc.contributor.coadvisorSilva, Clarisse Maria Luiz
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2025-11-25T14:39:49Z
dc.date.issued2025-10-22
dc.description.abstractObjetivo: O objetivo deste estudo foi avaliar o comportamento mecânico e a qualidade de superfície de uma resina de impressão 3D comparando com uma resina fresada em CAD/CAM. Material e Métodos: Foram utilizadas duas resinas: resina de impressão 3D (V-Print c&b temp, VOCO, Alemanha) e compósito nanohíbrido CAD/CAM (Grandio Bloc, VOCO, Alemanha). As amostras da resina impressa foram desenhadas no software Rhinoceros e fabricadas em impressora DLP (ASIGA, Austrália). As amostras da resina fresada em disco foram obtidas através de um disco para fresagem em uma cortadora de espécimes circulares e as barras foram cortadas com um disco de carborundum e peça reta. A rugosidade superficial (n=60) foi medida com rugosímetro de contato, registrando os parâmetros Ra e Rz. A microdureza Knoop (n=8) foi avaliada em testador digital. O módulo elástico (n=10) foi determinado pela técnica de excitação por impulso, utilizando barras de 40×15×2 mm. A resistência à flexão foi testada em barras de 25×2×2 mm, pela flexão de três pontos até a fratura. Resultados: A rugosidade superficial não apresentou diferença estatisticamente significativa entre os grupos (p>0,5). Na microdureza Knoop, os grupos apresentaram diferença estatística entre si (p<0,001), sendo a dureza da resina fresada maior. Módulo de elasticidade foi superior para a resina fresada (24,70 ± 2,29 GPa) em comparação à impressa (5,51 ± 0,45 GPa). Na resistência à flexão, resina impressa atingiu média de 124 ± 12,8 MPa. Conclusão: A resina impressa apresentou valores inferiores em comparação ao compósito nanohíbrido fresado, entretanto, manteve desempenho dentro de parâmetros clinicamente aceitáveis.pt
dc.description.abstractObjective: The objective of this study was to evaluate the mechanical behavior and surface quality of a 3D-printed resin compared to a milled CAD/CAM composite resin. Materials and Methods: Two resins were used: a 3D-printed resin (V-Print c&b temp, VOCO, Germany) and a nanohybrid CAD/CAM composite (Grandio Bloc, VOCO, Germany). The printed resin samples were designed using Rhinoceros software and manufactured with a DLP printer (ASIGA, Australia). The milled resin discs were obtained from CAD/CAM blocks using a specimen-cutting machine, and the bars were sectioned with a carborundum disc and straight handpiece. Surface roughness (n=60) was measured with a contact profilometer, recording the Ra and Rz parameters. Knoop microhardness (n=8) was evaluated using a digital hardness tester. The elastic modulus (n=10) was determined by the impulse excitation technique, using rectangular bars (40×15×2 mm). Flexural strength was tested on bars (25×2×2 mm) using a threepoint bending test until fracture. Results: Surface roughness showed no statistically significant difference between the groups (p > 0.05). For Knoop microhardness, a significant difference was found between groups (p < 0.001), with the milled resin presenting higher hardness values. The elastic modulus was higher for the milled resin (24.70 ± 2.29 GPa) compared to the printed one (5.51 ± 0.45 GPa). The flexural strength of the printed resin averaged 124 ± 12.8 MPa. Conclusion: The 3D-printed resin exhibited lower mechanical properties compared to the milled nanohybrid composite; however, it maintained clinically acceptable performanceen
dc.identifier.urihttps://hdl.handle.net/11449/315534
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso restritopt
dc.subjectImpressão tridimensionalpt
dc.subjectPrinting, three-dimensionalen
dc.subjectDesenho assistido por computadorpt
dc.subjectComputer-aided designen
dc.subjectMateriais dentáriospt
dc.subjectDental materialsen
dc.titleAvaliação da rugosidade superficial, módulo elástico, microdureza e resistência à flexão de uma resina temporária de longa duraçãopt
dc.title.alternativeEvaluation of surface roughness, elastic modulus, microhardness, and flexural strength of a long-term temporary resinen
dc.typeTrabalho de conclusão de cursopt
dspace.entity.typePublication
relation.isAuthorOfPublication5f1a18fa-5b0b-456c-9df5-2a94ddabca95
relation.isAuthorOfPublication.latestForDiscovery5f1a18fa-5b0b-456c-9df5-2a94ddabca95
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.examinationboard.typeBanca públicapt
unesp.undergraduateSão José dos Campos - ICT - Odontologiapt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
castro_dca_tcc_sjc.pdf
Tamanho:
962.3 KB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
2.14 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
autorização_castro_dca_tcc_sjc.pdf
Tamanho:
131.63 KB
Formato:
Adobe Portable Document Format
Descrição: