Publicação:
Effect of Misfit on Preload Maintenance of Retention Screws of Implant-Supported Prostheses

dc.contributor.authorAssunção, Wirley Goncalves [UNESP]
dc.contributor.authorSantos, Paulo Henrique dos [UNESP]
dc.contributor.authorDelben, Juliana Aparecida [UNESP]
dc.contributor.authorGomes, Erica Alves [UNESP]
dc.contributor.authorRicardo Barao, Valentim Adelino [UNESP]
dc.contributor.authorTabata, Lucas Fernando [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:30:24Z
dc.date.accessioned2014-05-20T13:43:54Z
dc.date.available2013-09-30T18:30:24Z
dc.date.available2014-05-20T13:43:54Z
dc.date.issued2009-10-01
dc.description.abstractThe aim of this study was to evaluate the effect of unilateral misfit at different levels on a crown-implant-retention screw system of implant-supported crowns. Hexagon castable UCLA abutments were cast in Co-Cr alloy to fabricate 48 metallic crowns divided into four groups (n = 12). Group A: crowns did not present misfit; Groups B, C and D: crowns were fabricated with unilateral misfit of 50, 100, and 200 mu m, respectively. The crowns were attached by titanium retention screw with 30 N/cm to external hexagonal osseointegrated implants embedded in acrylic resin. After 2 min, the retention screw of each replica was submitted to detorque evaluation by an analogic torque gauge. Three retention screws were used to perform detorque evaluation at each replica and the procedure was repeated twice with each screw. Each group was submitted to 72 detorque measurements. Data were evaluated by ANOVA and Tukey test (P < 0.05). All groups exhibited significant decrease (P < 0.05) in preload and the lowest decrease occurred in Group A. Groups B, C, and D were statistically significant different from Group A (P < 0.05), but there was no statistically significant difference between Groups B and D (P > 0.05). Crowns with unilateral misfit presented higher preload decrease than crowns completely fitted to osseointegrated implants.en
dc.description.affiliationSão Paulo State Univ UNESP, Dept Dent Mat & Prosthodont, Aracatuba Dent Sch, BR-16015050 Aracatuba, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ UNESP, Dept Dent Mat & Prosthodont, Aracatuba Dent Sch, BR-16015050 Aracatuba, SP, Brazil
dc.format.extent935-938
dc.identifierhttp://dx.doi.org/10.1007/s11665-008-9324-3
dc.identifier.citationJournal of Materials Engineering and Performance. New York: Springer, v. 18, n. 7, p. 935-938, 2009.
dc.identifier.doi10.1007/s11665-008-9324-3
dc.identifier.fileWOS000269897600012.pdf
dc.identifier.issn1059-9495
dc.identifier.lattes4438747643373395
dc.identifier.lattes0493479801083622
dc.identifier.orcid0000-0002-4100-5153
dc.identifier.urihttp://hdl.handle.net/11449/15357
dc.identifier.wosWOS:000269897600012
dc.language.isoeng
dc.publisherSpringer
dc.relation.ispartofJournal of Materials Engineering and Performance
dc.relation.ispartofjcr1.340
dc.relation.ispartofsjr0,611
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.subjectjoiningen
dc.subjectmechanical testingen
dc.subjecttitaniumen
dc.titleEffect of Misfit on Preload Maintenance of Retention Screws of Implant-Supported Prosthesesen
dc.typeArtigo
dcterms.licensehttp://www.asminternational.org/pdf/JTST_copyright.pdf
dcterms.rightsHolderSpringer
dspace.entity.typePublication
unesp.author.lattes4438747643373395
unesp.author.lattes0493479801083622[2]
unesp.author.orcid0000-0002-8903-0737[1]
unesp.author.orcid0000-0002-4100-5153[2]
unesp.author.orcid0000-0002-6391-9917[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
WOS000269897600012.pdf
Tamanho:
327.84 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: