Logotipo do repositório
 

Publicação:
Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogs

dc.contributor.authorWeng, Dietmar
dc.contributor.authorNagata, Maria José Hitomi [UNESP]
dc.contributor.authorBell, Matthias
dc.contributor.authorBosco, Álvaro Francisco [UNESP]
dc.contributor.authorNascimento de Melo, Luiz Gustavo [UNESP]
dc.contributor.authorRichter, Ernst-Juergen
dc.contributor.institutionUniv Wurzburg
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:29:47Z
dc.date.accessioned2014-05-20T13:43:13Z
dc.date.available2013-09-30T18:29:47Z
dc.date.available2014-05-20T13:43:13Z
dc.date.issued2008-11-01
dc.description.abstractObjectives: The vertical location of the implant-abutment connection influences the periimplant bone morphology. It is unknown, however, whether different microgap configurations cause different bone reactions. Therefore, in this study the bone morphologies of two different implant systems were compared.Material and methods: Three months after tooth extraction in eight mongrel dogs, two grit-blasted screw implants with internal Morse taper connection (ANK group) were placed on one side whereas the contralateral side received two oxidized screw implants with external hex (TIU group). One implant on each side was placed level with the bone (equicrestal), the second implant was inserted 1.5mm below bone level (subcrestal). After 3 months the implants were uncovered. Three months after stage two surgery, histometrical evaluations were performed in order to assess the periimplant bone levels (PBL), the first bone-to-implant contact points (BICP), the width (HBD) and the steepness (SLO) of the bone defect.Results: All implants osseointegrated clinically and histologically. Bone overgrowth of the microgap was seen in ANK implants only. No significant differences between ANK and TIU could be detected in neither vertical position for PBL and BICP. However, a tendency in favor of ANK was visible when the implants were placed subcrestally. In the parameters HBD (ANK equicrestal -0.23mm; TIU equicrestal -0.51mm; ANK subcrestal +0.19mm; TIU subcrestal -0.57mm) and SLO (ANK equicrestal 35.36 degrees; TIU equicrestal 63.22 degrees; ANK subcrestal 20.40 degrees; TIU subcrestal 44.43 degrees) more pronounced and significant differences were noted.Conclusions: Within the limits of this study, it is concluded that different microgap designs cause different shapes and sizes of the periimplant ('dish-shaped') bone defect in submerged implants both in equicrestal and subcrestal positions.en
dc.description.affiliationUniv Wurzburg, Sch Dent Med, Dept Prosthodont, Wurzburg, Germany
dc.description.affiliationSão Paulo State Univ Julio de Mesquita Filho UNES, Dept Surg & Integrated Clin, Dent Sch Araccatuba, Div Periodont, São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ Julio de Mesquita Filho UNES, Dept Surg & Integrated Clin, Dent Sch Araccatuba, Div Periodont, São Paulo, Brazil
dc.description.sponsorshipDentsply Friadent
dc.format.extent1141-1147
dc.identifierhttp://dx.doi.org/10.1111/j.1600-0501.2008.01564.x
dc.identifier.citationClinical Oral Implants Research. Malden: Wiley-blackwell, v. 19, n. 11, p. 1141-1147, 2008.
dc.identifier.doi10.1111/j.1600-0501.2008.01564.x
dc.identifier.issn0905-7161
dc.identifier.lattes8399870097572073
dc.identifier.lattes9831236034935598
dc.identifier.urihttp://hdl.handle.net/11449/15049
dc.identifier.wosWOS:000260133400008
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofClinical Oral Implants Research
dc.relation.ispartofjcr4.305
dc.relation.ispartofsjr2,462
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectbone morphologyen
dc.subjectequicrestal placementen
dc.subjecthistometric studyen
dc.subjectmicrogapen
dc.subjectsubcrestal placementen
dc.titleInfluence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogsen
dc.typeArtigopt
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes8399870097572073
unesp.author.lattes9831236034935598
unesp.author.orcid0000-0001-5903-5652[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentCirurgia e Clínica Integrada - FOApt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: