Publicação: Effect of framework soldering on the deformation of implant abutments after framework seating
dc.contributor.author | Mendes, Stella de N. C. | |
dc.contributor.author | Edwards Rezende, Carlos E. | |
dc.contributor.author | Moretti Neto, Rafael T. | |
dc.contributor.author | Sousa, Edson Antonio Capello [UNESP] | |
dc.contributor.author | Henrique Rubo, José | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade Federal de Alfenas (UFAL) | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.date.accessioned | 2016-03-02T13:00:41Z | |
dc.date.available | 2016-03-02T13:00:41Z | |
dc.date.issued | 2013 | |
dc.description.abstract | Introduction: Passive fit has been considered an important requirement for the longevity of implant-supported prostheses. Among the different steps of prostheses construction, casting is a feature that can influence the precision of fit and consequently the uniformity of possible deformation among abutments upon the framework connection. Purpose: This study aimed at evaluating the deformation of abutments after the connection of frameworks either cast in one piece or after soldering. Materials and Methods: A master model was used to simulate a human mandible with 5 implants. Ten frameworks were fabricated on cast models and divided into 2 groups. Strain gauges were attached to the mesial and distal sides of the abutments to capture their deformation after the framework’s screw retentions were tightened to the abutments. Results: The mean values of deformation were submitted to a 3-way analysis of variance that revealed significant differences between procedures and the abutment side. The results showed that none of the frameworks presented a complete passive fit. Conclusion: The soldering procedure led to a better although uneven distribution of compression strains on the abutments. | en |
dc.description.affiliation | Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Engenharia Mecânica, Faculdade de Engenharia de Bauru, Bauru, Av. Luiz Edmundo Carrijo Coube n. 14-01, Vargem Limpa, CEP 17033-360, SP, Brasil | |
dc.description.affiliation | Department of Clinics and Surgery, Alfenas Federal University, Alfenas, Brazil. | |
dc.description.affiliation | Department of Prosthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil | |
dc.description.affiliationUnesp | Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Engenharia Mecânica, Faculdade de Engenharia de Bauru, Bauru, Av. Luiz Edmundo Carrijo Coube n. 14-01, Vargem Limpa, CEP 17033-360, SP, Brasil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorshipId | FAPESP: 2001/025751-6 | |
dc.format.extent | 193-198 | |
dc.identifier | http://dx.doi.org/10.1097/ID.0b013e31828186e8 | |
dc.identifier.citation | Implant Dentistry, v. 22, n. 2, p. 193-198, 2013. | |
dc.identifier.doi | 10.1097/ID.0b013e31828186e8 | |
dc.identifier.issn | 1056-6163 | |
dc.identifier.lattes | 8934648262859482 | |
dc.identifier.uri | http://hdl.handle.net/11449/135326 | |
dc.language.iso | eng | |
dc.relation.ispartof | Implant Dentistry | |
dc.relation.ispartofjcr | 1.307 | |
dc.relation.ispartofsjr | 0,712 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Currículo Lattes | |
dc.title | Effect of framework soldering on the deformation of implant abutments after framework seating | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.author.lattes | 8934648262859482 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Engenharia, Bauru | pt |
unesp.department | Engenharia Mecânica - FEB | pt |