Logotipo do repositório
 

Publicação:
Shear Bond Strength of Different Repair Systems to Titanium After Water Aging

dc.contributor.authorHaneda, Isabella Gagliardi [UNESP]
dc.contributor.authorFonseca, Renata Garcia [UNESP]
dc.contributor.authorAbi-Rached, Filipe de Oliveira [UNESP]
dc.contributor.authorAdabo, Gelson Luis [UNESP]
dc.contributor.authorCruz, C. A. S. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:46:27Z
dc.date.available2014-05-20T13:46:27Z
dc.date.issued2012-05-01
dc.description.abstractThis study evaluated the shear bond strength (SBS) and stability of commercially pure titanium (CP Ti)/repair material interfaces promoted by different repair systems. One hundred CP Ti cast discs were divided into five repair system groups: 1) Epricord (EP); 2) Bistite 11 DC (BT); 3) Cojet (CJ); 4) Scotchbond Multi-Purpose Plus (SB) (control group); and 5) Cojet Sand plus Scotchbond Multi-Purpose Plus (CJSB). The specimens were stored in distilled water for 24 hours at 37 degrees C, thermal cycled (5000 cycles, 5 degrees-55 degrees C) and stored under the same conditions for either 24 hours or six months (n=10). SBS was tested and the data were analyzed by two-way analysis of variance (ANOVA) and Tukey test (alpha=.05). Failure mode was determined with a stereomicroscope (20x). The repair system, storage time, and their interaction significantly affected the SBS (p<0.001). At 24 hours, CJSB exhibited the highest SBS value, followed by CJ. At six months, these two groups had similar mean SBS (p>0.05) and higher means in comparison to the other groups. For both storage times, BT presented the lowest SBS, while the EP and SB groups did not differ significantly from one another (p>0.05). There were no significant differences in SBS between the storage times for the groups EP and CJ (p>0.05). The groups BT, SB, and CJSB showed 100% adhesive failure, irrespective of storage time. The CJSB group showed the highest SBS at both storage times. At six months, the CJ group exhibited a similar SBS mean value when compared to the CJSB group. Water storage adversely affected the groups BT, SB (control group), and CJSB. Considering SBS values, stability, and the failure mode simultaneously, the CJ group showed the best CP Ti repair performance.en
dc.description.affiliationUNESP Univ Estadual Paulista, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Araraquara, SP, Brazil
dc.description.affiliationUnespUNESP Univ Estadual Paulista, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Araraquara, SP, Brazil
dc.format.extent253-262
dc.identifierhttp://dx.doi.org/10.2341/11-231-L
dc.identifier.citationOperative Dentistry. Indianapolis: Operative Dentistry Inc, v. 37, n. 3, p. 253-262, 2012.
dc.identifier.doi10.2341/11-231-L
dc.identifier.issn0361-7734
dc.identifier.lattes3041561340615890
dc.identifier.lattes2851339311179809
dc.identifier.lattes9056474544845038
dc.identifier.urihttp://hdl.handle.net/11449/16447
dc.identifier.wosWOS:000311768200005
dc.language.isoeng
dc.publisherOperative Dentistry Inc
dc.relation.ispartofOperative Dentistry
dc.relation.ispartofjcr2.130
dc.relation.ispartofsjr1,180
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.titleShear Bond Strength of Different Repair Systems to Titanium After Water Agingen
dc.typeArtigopt
dcterms.rightsHolderOperative Dentistry Inc
dspace.entity.typePublication
relation.isDepartmentOfPublication3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isDepartmentOfPublication.latestForDiscovery3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes3041561340615890
unesp.author.lattes2851339311179809
unesp.author.lattes9056474544845038[5]
unesp.author.orcid0000-0002-0734-7926[4]
unesp.author.orcid0000-0001-6657-913X[2]
unesp.author.orcid0000-0001-8406-4797[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: