Logotipo do repositório

Ultrasonic activation of different self-etch adhesive systems – Dentin tubule penetration and push-out bond strength of fiber posts

dc.contributor.authorArrué, Thalita Ayres
dc.contributor.authorda Rosa, Ricardo Abreu
dc.contributor.authorMünchow, Eliseu Aldrighi
dc.contributor.authorSó, Gabriel Barcelos
dc.contributor.authorPereira, Jefferson Ricardo
dc.contributor.authorKuga, Milton Carlos [UNESP]
dc.contributor.authorSó, Marcus Vinicius Reis
dc.date.accessioned2026-06-25T18:09:06Z
dc.date.issued2025-08-01
dc.description.abstractObjectives: The objective of this study was to evaluate the dentin tubule penetration of three self-etching adhesive systems and the bond strength of fiber post cementation using standard protocols and ultrasonic activation of the adhesive system. Materials and Methods: Sixty extracted bovine teeth samples had their canals prepared and the apical thirds filled. Six groups were selected from the total sample. Clearfil SE, Prime and Bond, and Single Bond Universal adhesive systems were applied in two groups each. The standard adhesive application protocol was executed in one group, and ultrasonic activation of the adhesive system was executed in one group for each adhesive system. Afterward, fiber posts were cemented in all canals using resin cement (RelyX ARC). The samples were prepared and analyzed under confocal laser scanning microscopy and submitted to a push-out test to observe the adhesive's dentin tubule penetration and evaluate the bond strength values of the posts, respectively. Results: The dentin tubule penetration of the adhesives was more visible on the ultrasonic-activated adhesive groups. Using the standard adhesive protocol, Prime and Bond Universal presented the lowest bond strength values on the apical and cervical thirds and mean value (<i>P</i> &lt; 0.05). Clearfil SE presented the highest bond strength values among ultrasonic-activated adhesive system groups (<i>P</i> &lt; 0.05). Conclusions: Ultrasonic activation improved self-etch adhesive dentinal tubule penetration and bond strength of Clearfil SE and Prime and Bond Universal. Ultrasonic activation of self-etch adhesive systems influenced the prevalence of adhesive failure patterns.
dc.description.affiliationDepartment of Conservative Dentistry, School of Dentistry, Federal University of Rio Grande do Sul, Porto Alegre, Brazil
dc.description.affiliationProgram of Post Graduation in Health Science, Dental School, University of Southern Santa Catarina, Santa Catarina, Brazil
dc.description.affiliationDepartment of Restorative Dentistry (FOAR), School of Dentistry at Araraquara, São Paulo State University (UNESP), Araraquara, São Paulo, Brazil
dc.description.affiliationUnespDepartment of Restorative Dentistry (FOAR), School of Dentistry at Araraquara, São Paulo State University (UNESP), Araraquara, São Paulo, Brazil
dc.identifierhttps://app.dimensions.ai/details/publication/pub.1191401900
dc.identifier.dimensionspub.1191401900
dc.identifier.doi10.4103/jcde.jcde_39_25
dc.identifier.issn0972-0707
dc.identifier.issn0974-5203
dc.identifier.issn2950-4716
dc.identifier.issn2950-4708
dc.identifier.orcid0000-0001-6568-7403
dc.identifier.orcid0000-0002-6925-0097
dc.identifier.orcid0000-0003-1565-4907
dc.identifier.orcid0000-0001-5663-3710
dc.identifier.orcid0000-0001-5728-8293
dc.identifier.orcid0000-0002-1393-5900
dc.identifier.pmcidPMC12377670
dc.identifier.pmid40860381
dc.identifier.urihttps://hdl.handle.net/11449/326648
dc.publisherWolters Kluwer
dc.relation.ispartofJournal of Conservative Dentistry; n. 8; v. 28; p. 826-832
dc.rights.accessRightsAcesso abertopt
dc.rights.sourceRightsoa_all
dc.rights.sourceRightsgold
dc.sourceDimensions
dc.titleUltrasonic activation of different self-etch adhesive systems – Dentin tubule penetration and push-out bond strength of fiber posts
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
JCDE-28-826.pdf
Tamanho:
1,23 MB
Formato:
Adobe Portable Document Format