Publicação: Bond Strength of Two Resin Cements on Dentin Using Different Cementation Strategies
dc.contributor.author | Melo, Renata Marques [UNESP] | |
dc.contributor.author | Ozcan, Mutlu | |
dc.contributor.author | Barbosa, Silvia Helena [UNESP] | |
dc.contributor.author | Galhano, Graziela A. P. [UNESP] | |
dc.contributor.author | Amaral, Regina [UNESP] | |
dc.contributor.author | Bottino, Marco Antonio [UNESP] | |
dc.contributor.author | Valandro, Luiz Felipe | |
dc.contributor.institution | Univ Zurich | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade Federal de Santa Maria (UFSM) | |
dc.date.accessioned | 2014-05-20T14:05:04Z | |
dc.date.available | 2014-05-20T14:05:04Z | |
dc.date.issued | 2010-01-01 | |
dc.description.abstract | Purpose:This study evaluated the microtensile bond strength of two resin cements to dentin either with their corresponding self-etching adhesives or employing the three-step etch-and-rinse technique. The null hypothesis was that the etch-and-rinse adhesive system would generate higher bond strengths than the self-etching adhesives.Materials and Methods:Thirty-two human molars were randomly divided into four groups (N = 32, n = 8/per group): G1) ED Primer self-etching adhesive + Panavia F; G2) All-Bond 2 etch-and-rinse adhesive + Panavia F; G3) Multilink primer A/B self-etching adhesive + Multilink resin cement; G4) All-Bond 2 + Multilink. After cementation of composite resin blocks (5 x 5 x 4 mm), the specimens were stored in water (37 degrees C, 24 hours), and sectioned to obtain beams (+/- 1 mm2 of adhesive area) to be submitted to microtensile test. The data were analyzed using 2-way analysis of variance and Tukey's test (alpha = 0.05).Results:Although the cement type did not significantly affect the results (p = 0.35), a significant effect of the adhesive system (p = 0.0001) was found on the bond strength results. Interaction terms were not significant (p = 0.88751). The etch-and-rinse adhesive provided significantly higher bond strength values (MPa) with both resin cements (G2: 34.4 +/- 10.6; G4: 33.0 +/- 8.9) compared to the self-etching adhesive systems (G1: 19.8 +/- 6.6; G3: 17.8 +/- 7.2) (p < 0.0001). Pretest failures were more frequent in the groups where self-etching systems were used.Conclusion:Although the cement type did not affect the results, there was a significant effect of changing the bonding strategy. The use of the three-step etch-and-rinse adhesive resulted in significantly higher bond strength for both resin cements on dentin.CLINICAL SIGNIFICANCEDual polymerized resin cements tested could deliver higher bond strength to dentin in combination with etch-and-rinse adhesive systems as opposed to their use in combination with self-etching adhesives.(J Esthet Restor Dent 22:262-269, 2010). | en |
dc.description.affiliation | Univ Zurich, Dent Mat Unit, Ctr Dent & Oral Med, Clin Fixed & Removable Prosthodont & Dent Mat, CH-8032 Zurich, Switzerland | |
dc.description.affiliation | São Paulo State Univ UNESP, Sao Jose dos Campos Dent Sch, Dept Dent Mat & Prosthodont, São Paulo, Brazil | |
dc.description.affiliation | Universidade Federal de Santa Maria (UFSM), Sch Dent, Dept Restorat Dent, Div Prosthodont, BR-97119900 Santa Maria, RS, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ UNESP, Sao Jose dos Campos Dent Sch, Dept Dent Mat & Prosthodont, São Paulo, Brazil | |
dc.format.extent | 262-268 | |
dc.identifier | http://dx.doi.org/10.1111/j.1708-8240.2010.00349.x | |
dc.identifier.citation | Journal of Esthetic and Restorative Dentistry. Malden: Wiley-blackwell, v. 22, n. 4, p. 262-268, 2010. | |
dc.identifier.doi | 10.1111/j.1708-8240.2010.00349.x | |
dc.identifier.issn | 1496-4155 | |
dc.identifier.lattes | 9234456003563666 | |
dc.identifier.uri | http://hdl.handle.net/11449/22818 | |
dc.identifier.wos | WOS:000280644400011 | |
dc.language.iso | eng | |
dc.publisher | Wiley-Blackwell | |
dc.relation.ispartof | Journal of Esthetic and Restorative Dentistry | |
dc.relation.ispartofjcr | 1.531 | |
dc.relation.ispartofsjr | 0,753 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.title | Bond Strength of Two Resin Cements on Dentin Using Different Cementation Strategies | en |
dc.type | Artigo | |
dcterms.license | http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1601-0825/homepage/ForAuthors.html | |
dcterms.rightsHolder | Wiley-blackwell | |
dspace.entity.type | Publication | |
unesp.author.lattes | 9234456003563666 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campos | pt |
unesp.department | Materiais Odontológicos e Prótese - ICT | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: