Publicação: Reliability of marginal microleakage assessment by visual and digital methods
dc.contributor.author | Alvarenga, Fábio Augusto de Santi [UNESP] | |
dc.contributor.author | Pinelli, Camila [UNESP] | |
dc.contributor.author | Loffredo, Leonor de Castro Monteiro [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2015-08-06T16:13:56Z | |
dc.date.available | 2015-08-06T16:13:56Z | |
dc.date.issued | 2015 | |
dc.description.abstract | The aim of this study was to investigate the reliability of visual and digital methods to assess marginal microleakage in vitro. Materials and Methods: Typical Class V preparations were made in bovine teeth and filled with composite resin. After dye penetration (0.5% basic fuchsin), teeth were sectioned and the 53 obtained fragments were assessed according to visual (stereomicroscope) and digital methods (Image Tool Software ® -ITS) (University of Texas Health Science Center-San Antonio Dental School, USA). Two calibrated examiners (A and B) evaluated dye penetration, by means of a stereomicroscope with ×20 magnification (scores), and by the ITS (millimeters). The intra- and inter-examiner agreement was estimated according to Kappa statistics (κ), and intraclass correlation coefficient (ρ). Results: In relation to the visual method, the intra-examiner agreement was almost perfect (κA = 0.87) and substantial (κB = 0.76), respectively to the examiner A and B. The inter-examiner agreement showed an almost perfect reliability (κ = 0.84). For the digital method, the intra-examiner agreement was almost perfect for both examiners and equal to ρ = 0.99, and so was the inter-examiner agreement value. Conclusion: Visual (stereomicroscope) and digital methods (ITS) showed high levels of intra- and inter-examiner reproducibility when marginal microleakage was assessed. | en |
dc.description.affiliation | Universidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, n. 1680, Centro, CEP 14801-903, SP, Brasil | |
dc.description.affiliationUnesp | Universidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, n. 1680, Centro, CEP 14801-903, SP, Brasil | |
dc.description.affiliationUnesp | Department of Community Dentistry | |
dc.description.affiliationUnesp | Department of Restorative Dentistry | |
dc.format.extent | 1-5 | |
dc.identifier | http://www.eurjdent.com/article.asp?issn=1305-7456;year=2015;volume=9;issue=1;spage=1;epage=5;aulast=de | |
dc.identifier.citation | European Journal of Dentistry, v. 9, n. 1, p. 1-5, 2015. | |
dc.identifier.doi | 10.4103/1305-7456.149628 | |
dc.identifier.issn | 1305-7456 | |
dc.identifier.lattes | 5663622442588861 | |
dc.identifier.lattes | 4021286315086194 | |
dc.identifier.lattes | 3469868853605212 | |
dc.identifier.lattes | 5663622442588861 | |
dc.identifier.uri | http://hdl.handle.net/11449/126095 | |
dc.language.iso | eng | |
dc.relation.ispartof | European Journal of Dentistry | |
dc.relation.ispartofsjr | 0,749 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Currículo Lattes | |
dc.subject | Assessment | en |
dc.subject | Composite resin | en |
dc.subject | Microleakage | en |
dc.subject | Reproducibility of results | en |
dc.title | Reliability of marginal microleakage assessment by visual and digital methods | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.author.lattes | 5663622442588861 | |
unesp.author.lattes | 4021286315086194[2] | |
unesp.author.lattes | 3469868853605212 | |
unesp.author.lattes | 5663622442588861 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Odontologia Social - FOAR | pt |