Publicação: Influence of Framework Material and Posterior Implant Angulation in Full-Arch All-on-4 Implant-Supported Prosthesis Stress Concentration
dc.contributor.author | Tribst, João Paulo Mendes | |
dc.contributor.author | de Morais, Dayana Campanelli [UNESP] | |
dc.contributor.author | de Matos, Jefferson David Melo [UNESP] | |
dc.contributor.author | Lopes, Guilherme da Rocha Scalzer [UNESP] | |
dc.contributor.author | Dal Piva, Amanda Maria de Oliveira | |
dc.contributor.author | Borges, Alexandre Luiz Souto [UNESP] | |
dc.contributor.author | Bottino, Marco Antonio [UNESP] | |
dc.contributor.author | Lanzotti, Antonio | |
dc.contributor.author | Martorelli, Massimo | |
dc.contributor.author | Ausiello, Pietro | |
dc.contributor.institution | University of Amsterdam and Vrije Universiteit Amsterdam | |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
dc.contributor.institution | University of Naples Federico II | |
dc.date.accessioned | 2022-05-01T13:11:35Z | |
dc.date.available | 2022-05-01T13:11:35Z | |
dc.date.issued | 2022-01-01 | |
dc.description.abstract | This study evaluated the influence of distal implants angulation and framework material in the stress concentration of an All-on-4 full-arch prosthesis. A full-arch implant-supported prosthesis 3D model was created with different distal implant angulations and cantilever arms (30° with 10-mm cantilever; 45° with 10-mm cantilever and 45° with 6-mm cantilever) and framework materials (Cobalt–chrome [CoCr alloy], Yttria-stabilized tetragonal zirconia polycrystal [Y-TZP] and polyetheretherketone [PEEK]). Each solid was imported to computer-aided engineering software, and tetrahedral elements formed the mesh. Material properties were assigned to each solid with isotropic and homogeneous behavior. The contacts were considered bonded. A vertical load of 200 N was applied in the distal region of the cantilever arm, and stress was evaluated in Von Misses (σVM) for prosthesis components and the Maximum (σMAX) and Minimum (σMIN) Principal Stresses for the bone. Distal implants angled in 45° with a 10-mm cantilever arm showed the highest stress concentration for all structures with higher stress magnitudes when the PEEK framework was considered. However, distal implants angled in 45° with a 6-mm cantilever arm showed promising mechanical responses with the lowest stress peaks. For the All-on-4 concept, a 45° distal implants angulation is only beneficial if it is possible to reduce the cantilever’s length; otherwise, the use of 30° should be considered. Comparing with PEEK, the YTZP and CoCr concentrated stress in the framework structure, reducing the stress in the prosthetic screw. | en |
dc.description.affiliation | Department of Dental Materials Academic Centre for Dentistry Amsterdam (ACTA) University of Amsterdam and Vrije Universiteit Amsterdam | |
dc.description.affiliation | Department of Dental Materials and Prosthodontics Institute of Science and Technology São Paulo State University-UNESP | |
dc.description.affiliation | Fraunhofer JL IDEAS Department of Industrial Engineering University of Naples Federico II | |
dc.description.affiliation | School of Dentistry University of Naples Federico II, Via S. Pansini 5 | |
dc.description.affiliationUnesp | Department of Dental Materials and Prosthodontics Institute of Science and Technology São Paulo State University-UNESP | |
dc.identifier | http://dx.doi.org/10.3390/dj10010012 | |
dc.identifier.citation | Dentistry Journal, v. 10, n. 1, 2022. | |
dc.identifier.doi | 10.3390/dj10010012 | |
dc.identifier.issn | 2304-6767 | |
dc.identifier.scopus | 2-s2.0-85123774655 | |
dc.identifier.uri | http://hdl.handle.net/11449/234071 | |
dc.language.iso | eng | |
dc.relation.ispartof | Dentistry Journal | |
dc.source | Scopus | |
dc.subject | Dental implants | |
dc.subject | Finite element analysis | |
dc.subject | Polymers | |
dc.subject | Prosthodontics | |
dc.title | Influence of Framework Material and Posterior Implant Angulation in Full-Arch All-on-4 Implant-Supported Prosthesis Stress Concentration | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campos | pt |
unesp.department | Materiais Odontológicos e Prótese - ICT | pt |