Logo do repositório

Linear relationship between potential and concentration in flow potentiometry

dc.contributor.authorNeto, José Anchieta Gomes [UNESP]
dc.contributor.authorZagatto, Elias Ayres Guidetti
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2022-04-28T20:52:53Z
dc.date.available2022-04-28T20:52:53Z
dc.date.issued2000-01-01
dc.description.abstractIn potentiometric-flow systems, linear-potential responses for logarithmic concentrations can be attained for first-(or pseudo-first-) order reactions in which the monitored chemical species react with the analyte during a fixed time interval. To demonstrate this property, the determination of glycerol based on its oxidation by periodate and potentiometric monitoring of the remaining periodate was selected. Influence of reagent concentration and timing on the linearity of the analytical curve were investigated. A mathematical treatment was derived, and potentialities/limitations of the approach were outlined. The system was applied to analysis of soap and lixivia samples. The analytical curve within 200 and 2000 mg L-1 (r = 0.99975; n = 5) was described as E = 8.166+0.0478 [glycerol]. The sample throughput was 100 h-1, and a measurement repeatability within 0.5 mV was always observed. By applying a t-test, there was no statistical difference between the results obtained by the proposed procedure and by iodimetric titration at the 95% confidence level.en
dc.description.affiliationDepto. de Quim. Analítica Instituto de Química UNESP, PO Box 355, 14800- 900 Araraquara-SP
dc.description.affiliationCtro. de Ener. Nucl. na Agricultura USP, PO Box 96, 13400-970 Piracicaba-SP
dc.description.affiliationUnespDepto. de Quim. Analítica Instituto de Química UNESP, PO Box 355, 14800- 900 Araraquara-SP
dc.format.extent41-45
dc.identifierhttp://dx.doi.org/10.1002/(SICI)1098-2728(2000)12:1<41
dc.identifier.citationLaboratory Robotics and Automation, v. 12, n. 1, p. 41-45, 2000.
dc.identifier.doi10.1002/(SICI)1098-2728(2000)12:1<41
dc.identifier.issn0895-7533
dc.identifier.scopus2-s2.0-6744237800
dc.identifier.urihttp://hdl.handle.net/11449/225505
dc.language.isoeng
dc.relation.ispartofLaboratory Robotics and Automation
dc.sourceScopus
dc.titleLinear relationship between potential and concentration in flow potentiometryen
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublicationbc74a1ce-4c4c-4dad-8378-83962d76c4fd
relation.isOrgUnitOfPublication.latestForDiscoverybc74a1ce-4c4c-4dad-8378-83962d76c4fd
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos