Publicação: Study of constructed wetlands effluent disinfected with ozone
dc.contributor.author | Miranda, N. D. [UNESP] | |
dc.contributor.author | Oliveira, E. L. [UNESP] | |
dc.contributor.author | Silva, G. H. R. [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2015-03-18T15:56:12Z | |
dc.date.available | 2015-03-18T15:56:12Z | |
dc.date.issued | 2014-01-01 | |
dc.description.abstract | The purpose of this research was to study the disinfection of sanitary effluent from constructed wetlands, evaluating the oxidation of organic matter, the formation of formaldehyde, as well as the efficiency of total coliforms and Escherichia coli inactivation. A constant flow of ozone was applied to the batch system in 5 and 10mg.O-3 L-1 doses with contact times of 5 and 10min. This study revealed that the average values of formaldehyde formation ranged between 259.00 and 379.00 mu g L-1, which means that the values are within World Health Organization recommended values. The total coliforms and E. coli showed complete inactivation in almost all tests. The dose of ozone 5 mg.O-3 L-1 and contact time of 5 min were sufficient for a significant reduction of the concentration levels of pathogens in constructed wetlands effluent with similar characteristics, thus allowing for its agricultural reuse. | en |
dc.description.affiliation | UNESP Univ Estadual Paulista, Fac Engn, Dept Civil Engn, BR-17033360 Bauru, SP, Brazil | |
dc.description.affiliationUnesp | UNESP Univ Estadual Paulista, Fac Engn, Dept Civil Engn, BR-17033360 Bauru, SP, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | postgraduate program in Civil and Environmental Engineering | |
dc.description.sponsorshipId | FAPESP: 12/05297-9 | |
dc.description.sponsorshipId | FAPESP: 11/10816-2 | |
dc.format.extent | 108-113 | |
dc.identifier | http://dx.doi.org/10.2166/wst.2014.202 | |
dc.identifier.citation | Water Science And Technology. London: Iwa Publishing, v. 70, n. 1, p. 108-113, 2014. | |
dc.identifier.doi | 10.2166/wst.2014.202 | |
dc.identifier.issn | 0273-1223 | |
dc.identifier.lattes | 4612233331152255 | |
dc.identifier.lattes | 9415339655312598 | |
dc.identifier.uri | http://hdl.handle.net/11449/117456 | |
dc.identifier.wos | WOS:000341181200016 | |
dc.language.iso | eng | |
dc.publisher | Iwa Publishing | |
dc.relation.ispartof | Water Science And Technology | |
dc.relation.ispartofjcr | 1.247 | |
dc.relation.ispartofsjr | 0,429 | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Web of Science | |
dc.subject | by-products | en |
dc.subject | disinfection | en |
dc.subject | sanitary wastewater | en |
dc.subject | ozone | en |
dc.title | Study of constructed wetlands effluent disinfected with ozone | en |
dc.type | Artigo | |
dcterms.rightsHolder | Iwa Publishing | |
dspace.entity.type | Publication | |
unesp.author.lattes | 4612233331152255 | |
unesp.author.lattes | 9415339655312598 | |
unesp.author.orcid | 0000-0002-0741-8966[3] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Engenharia, Bauru | pt |
unesp.department | Engenharia Civil e Ambiental - FEB | pt |