Publicação: iCONVERT: an integrated device for the UV-assisted determination of H2S via mid-infrared gas sensors
dc.contributor.author | Petruci, João Flavio da Silveira [UNESP] | |
dc.contributor.author | Cardoso, Arnaldo Alves [UNESP] | |
dc.contributor.author | Wilk, Andreas | |
dc.contributor.author | Kokoric, Vjekoslav | |
dc.contributor.author | Mizaikoff, Boris | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | University of Ulm | |
dc.date.accessioned | 2015-12-07T15:39:02Z | |
dc.date.available | 2015-12-07T15:39:02Z | |
dc.date.issued | 2015-10-06 | |
dc.description.abstract | In this technical note, we describe an integrated device platform for performing in-flow gaseous conversion reactions based on ultraviolet (UV) irradiation. The system combines, using the same footprint, an integrated UV-conversion device (iCONVERT), a preconcentrator unit (iPRECON), and a new generation of mid-infrared (MIR) gas cell simultaneously serving as a photon conduit, i.e., so-called substrate-integrated hollow waveguide (iHWG) optically coupled to a compact Fourier transform-infrared (FT-IR) spectrometer. The iCONVERT is assembled from two blocks of aluminum (dimensions, 75 mm × 50 mm × 40 mm; L × W × D) containing 4 miniaturized UV-lamps (47mm × 6 mm × 47 mm each). For the present study, the iPRECON-iCONVERT-iHWG sensing platform has specifically been tailored to the determination of H2S in gaseous samples. Thereby, the quantitative UV-assisted conversion of the rather weak IR-absorber H2S into the more pronouncedly responding SO2 is used for hydrogen sulfide detection. A linear calibration model was established in the range of 7.5 to 100 ppmv achieving a limit of detection at 1.5 ppmv using 10 min of sample preconcentration (onto Molecular Sieve 5A) at a flow rate of 200 mL min(-1). When compared to a conventional UV-conversion system, the iCONVERT revealed similar performance. Considering the potential for system miniaturization using, e.g., dedicated quantum cascade lasers (QCL) in lieu of the FT-IR spectrometer, the developed sensing platform may be further evolved into a hand-held device. | en |
dc.description.affiliation | São Paulo State University (UNESP), Department of Analytical Chemistry, CEP 14800-970, Araraquara, São Paulo, Brazil | |
dc.description.affiliation | University of Ulm , Institute of Analytical and Bioanalytical Chemistry, 89081, Ulm, Germany. | |
dc.description.affiliationUnesp | São Paulo State University (UNESP), Department of Analytical Chemistry, CEP 14800-970, Araraquara, São Paulo, Brazil. | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorshipId | FAPESP: 2014/23974-3 | |
dc.format.extent | 9580-9583 | |
dc.identifier | http://dx.doi.org/10.1021/acs.analchem.5b02731 | |
dc.identifier.citation | Analytical Chemistry, v. 87, n. 19, p. 9580-9583, 2015. | |
dc.identifier.doi | 10.1021/acs.analchem.5b02731 | |
dc.identifier.issn | 1520-6882 | |
dc.identifier.lattes | 9165109840414837 | |
dc.identifier.pubmed | 26369573 | |
dc.identifier.uri | http://hdl.handle.net/11449/131628 | |
dc.language.iso | eng | |
dc.relation.ispartof | Analytical Chemistry | |
dc.relation.ispartofsjr | 2,362 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | PubMed | |
dc.title | iCONVERT: an integrated device for the UV-assisted determination of H2S via mid-infrared gas sensors | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.author.lattes | 9165109840414837[2] | |
unesp.author.orcid | 0000-0003-2046-995X[2] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |