Publicação: Simultaneous Determination of Phenanthrene and Benzo(a)pyrene in Water Samples by Synchronous Fluorescence Spectroscopy
dc.contributor.author | Sposito, Thiago Luiz [UNESP] | |
dc.contributor.author | Bisinoti, Marcia Cristina [UNESP] | |
dc.contributor.author | Moreira, Altair Benedito [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T14:03:09Z | |
dc.date.available | 2014-05-20T14:03:09Z | |
dc.date.issued | 2009-01-01 | |
dc.description.abstract | A simple and sensitive method was developed to simultaneously determine phenanthrene and benzo(a) pyrene in water samples using synchronous fluorescence spectroscopy with a 56-nm Delta lambda. The method was used to simultaneously determine both compounds in samples of spiked surface water. Analytical recoveries were 96.9-101.1% for phenanthrene and 95.8-103.5% for benzo(a) pyrene. Analytical results were checked for precision with 15 measurements for each compound. Relative standard deviations were 1.9% for phenanthrene and 2.9% for benzo(a) pyrene, which shows that the proposed method is quite precise. | en |
dc.description.affiliation | São Paulo State Univ Julio de Mesquita Filho, Inst Biosci Letters & Exact Sci, Chem & Environm Sci Dept, BR-15054000 Sao Jose do Rio Preto, SP, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ Julio de Mesquita Filho, Inst Biosci Letters & Exact Sci, Chem & Environm Sci Dept, BR-15054000 Sao Jose do Rio Preto, SP, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorshipId | FAPESP: 07/50461-3 | |
dc.description.sponsorshipId | FAPESP: 05/51242-8 | |
dc.format.extent | 2271-2279 | |
dc.identifier | http://dx.doi.org/10.1080/00032710903082523 | |
dc.identifier.citation | Analytical Letters. Philadelphia: Taylor & Francis Inc, v. 42, n. 14, p. 2271-2279, 2009. | |
dc.identifier.doi | 10.1080/00032710903082523 | |
dc.identifier.issn | 0003-2719 | |
dc.identifier.lattes | 3264480044529380 | |
dc.identifier.lattes | 5323771001380189 | |
dc.identifier.uri | http://hdl.handle.net/11449/22256 | |
dc.identifier.wos | WOS:000270088000011 | |
dc.language.iso | eng | |
dc.publisher | Taylor & Francis Inc | |
dc.relation.ispartof | Analytical Letters | |
dc.relation.ispartofjcr | 1.206 | |
dc.relation.ispartofsjr | 0,344 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | Benzo(a)pyrene | en |
dc.subject | phenanthrene | en |
dc.subject | synchronous fluorescence spectroscopy | en |
dc.title | Simultaneous Determination of Phenanthrene and Benzo(a)pyrene in Water Samples by Synchronous Fluorescence Spectroscopy | en |
dc.type | Artigo | |
dcterms.license | http://journalauthors.tandf.co.uk/permissions/reusingOwnWork.asp | |
dcterms.rightsHolder | Taylor & Francis Inc | |
dspace.entity.type | Publication | |
unesp.author.lattes | 3264480044529380 | |
unesp.author.lattes | 5323771001380189[3] | |
unesp.author.orcid | 0000-0001-7903-2360[3] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Biociências, Letras e Ciências Exatas, São José do Rio Preto | pt |
unesp.department | Química e Ciências Ambientais - IBILCE | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: