dc.contributor.authorMortezaei, Ali
dc.contributor.authorLute, Christopher
dc.contributor.authorSimões, M. Godoy
dc.contributor.authorMarafão, Fernando P. [UNESP]
dc.contributor.authorBoglia, Alessandro [UNESP]
dc.contributor.institutionElectrical Engineering and Computer Science, Colorado School of Mines
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T17:25:12Z
dc.date.available2018-12-11T17:25:12Z
dc.date.issued2014-01-01
dc.description.abstractThis paper investigates three different control techniques for controlling shunt active compensators for harmonic, reactive power and unbalance compensation. The considered methods were the instantaneous real and imaginary power theory (PQ), the Conservative Power Theory (CPT) and the synchronous reference frame method (DQ). So, the major goal is to explore the main similarities and differences in terms of steady state performance, dynamic response and computational complexity of each compensation method. Additionally, the paper also discusses how to achieve selective compensation by means of every technique, by means of suitable power and current decompositions. A three-phase grid with unbalanced non-linear load and non-negligible line impedance was used for comparing the approaches under ideal and deteriorated voltage conditions.en
dc.description.affiliationElectrical Engineering and Computer Science, Colorado School of Mines
dc.description.affiliationControl and Automation Engineering, UNESP - Univ Estadual Paulista
dc.description.affiliationUnespControl and Automation Engineering, UNESP - Univ Estadual Paulista
dc.format.extent2994-3001
dc.identifierhttp://dx.doi.org/10.1109/ECCE.2014.6953807
dc.identifier.citation2014 IEEE Energy Conversion Congress and Exposition, ECCE 2014, p. 2994-3001.
dc.identifier.doi10.1109/ECCE.2014.6953807
dc.identifier.scopus2-s2.0-84934301158
dc.identifier.urihttp://hdl.handle.net/11449/177389
dc.language.isoeng
dc.relation.ispartof2014 IEEE Energy Conversion Congress and Exposition, ECCE 2014
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.titlePQ, DQ and CPT control methods for shunt active compensators - A comparative studyen
dc.typeTrabalho apresentado em evento
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, Sorocabapt
unesp.departmentEngenharia de Controle e Automação - ICTSpt

Arquivos