Evaluation of the Peri-Implant Tissues of Patients with Severe Bone Atrophy Treated with a New Short and Extra-Short Implant System—A Pilot Study
| dc.contributor.author | de Moraes, Kely Cristina | |
| dc.contributor.author | Thomé, Geninho | |
| dc.contributor.author | Fontão, Flávia Noemy Gasparini Kiatake | |
| dc.contributor.author | Cartelli, Carolina Accorsi | |
| dc.contributor.author | Marcantonio, Rosemary Adriana Chierici [UNESP] | |
| dc.contributor.author | de Almeida Malzoni, Carolina Mendonça [UNESP] | |
| dc.contributor.author | Marcantonio, Elcio [UNESP] | |
| dc.date.accessioned | 2026-06-30T17:46:48Z | |
| dc.date.issued | 2024-09-29 | |
| dc.description.abstract | This study aimed to assess clinical and radiographic outcomes, including implant survival, marginal bone loss, and patient satisfaction, in individuals with severe bone atrophy treated using a newly developed system of short and extra-short implants. A total of 44 implants (37 short and 7 extra-short) were placed with immediate loading in 11 patients. The patients were followed up at between 6 and 24 months. Bone changes, keratinized mucosa, bleeding on probing, probing depth, crown-to-implant ratio, and patient satisfaction were evaluated. An implant survival and success rate of 100% was observed. The peri-implant bone condition showed no significant associations between marginal bone loss (MBL) and gingival recession. In extra-short implants, the crown-to-implant ratio did not affect MBL in the evaluated times. However, short implants showed a statistically significant inverse correlation between mesial measurement and crown-to-implant ratio (<i>p</i> = 0.006) and between distal measurement and crown-to-implant ratio (<i>p</i> = 0.004) over six months. Plaque was present in the mesiobuccal regions in 38.64% of the implants, with extra-short implants having the highest relative frequency (71.4%). Bleeding was observed in 18.9% of the short implants in the mesiolingual region and 14.3% of the extra-short implants. There was a statistically significant association between bleeding on probing in the mesiobuccal region and the type of implant (<i>p</i> = 0.026). The analysis of probing depth showed no difference between the types of implants. Within the limits of this study, short and extra-short implants presented similar clinical and radiographic behavior of soft and hard tissues in the evaluated times. | |
| dc.description.affiliation | Odontology at Ilapeo College, Curitiba 80710-150, Brazil;, kelycmoraes@hotmail.com, (K.C.d.M.);, geninho@ilapeo.com.br, (G.T.);, fgaspar@ilapeo.com.br, (F.N.G.K.F.);, carolina.accorsi@hotmail.com, (C.A.C.) | |
| dc.description.affiliation | Department of Diagnosis and Surgery, School of Dentistry of Araraquara, São Paulo State University (Unesp), Araraquara 14801-385, Brazil;, adriana.marcantonio@unesp.br, (R.A.C.M.);, ca.malzoni@gmail.com, (C.M.d.A.M.) | |
| dc.description.affiliationUnesp | Department of Diagnosis and Surgery, School of Dentistry of Araraquara, São Paulo State University (Unesp), Araraquara 14801-385, Brazil;, adriana.marcantonio@unesp.br, (R.A.C.M.);, ca.malzoni@gmail.com, (C.M.d.A.M.) | |
| dc.identifier | https://app.dimensions.ai/details/publication/pub.1176174642 | |
| dc.identifier.dimensions | pub.1176174642 | |
| dc.identifier.doi | 10.3390/jfb15100288 | |
| dc.identifier.issn | 2079-4983 | |
| dc.identifier.orcid | 0000-0003-0209-4058 | |
| dc.identifier.orcid | 0000-0003-4563-2442 | |
| dc.identifier.orcid | 0000-0002-5052-7439 | |
| dc.identifier.orcid | 0000-0003-1294-2305 | |
| dc.identifier.pmcid | PMC11508527 | |
| dc.identifier.pmid | 39452587 | |
| dc.identifier.uri | https://hdl.handle.net/11449/326923 | |
| dc.publisher | MDPI | |
| dc.relation.ispartof | Journal of Functional Biomaterials; n. 10; v. 15; p. 288 | |
| dc.rights.accessRights | Acesso aberto | pt |
| dc.rights.sourceRights | oa_all | |
| dc.rights.sourceRights | gold | |
| dc.source | Dimensions | |
| dc.title | Evaluation of the Peri-Implant Tissues of Patients with Severe Bone Atrophy Treated with a New Short and Extra-Short Implant System—A Pilot Study | |
| dc.type | Artigo | pt |
| dspace.entity.type | Publication | |
| relation.isOrgUnitOfPublication | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
| unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
Arquivos
Pacote original
1 - 1 de 1
Carregando...
- Nome:
- jfb-15-00288.pdf
- Tamanho:
- 3,13 MB
- Formato:
- Adobe Portable Document Format

