Evaluation of primary stability in modified implants: Analysis by resonance frequency and insertion torque
| dc.contributor.author | Sciasci, Plínio [UNESP] | |
| dc.contributor.author | Casalle, Nicole [UNESP] | |
| dc.contributor.author | Vaz, Luís Geraldo [UNESP] | |
| dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
| dc.date.accessioned | 2018-12-11T17:20:53Z | |
| dc.date.available | 2018-12-11T17:20:53Z | |
| dc.date.issued | 2018-06-01 | |
| dc.description.abstract | Background: Changes in the macrogeometry of dental implants are known to influence primary stability and the osseointegration process. Purpose: The purpose of the present in vitro study was to evaluate the mechanical behavior of geometric changes in the apex region of dental implants. Methods: Thirty-five cylindrical dental implants (Titamax Ti; Neodent) were machined at the apical third to reproduce the experimental groups: without apical cut (Wc), apical bi-split cut, apical tri-split cut, apical quadri-split cut (Qs). One (control group) (Titamax Ti Ex) (n = 7) without any modifications was added. The implants had the same final dimensions (4.1 x 11 mm2). All implants were inserted into artificial bone blocks and were evaluated by insertion torque and resonance frequency by ISQ values (Osstell). Two-tailed analysis of variance (One-way ANOVA) and Tukey's post-test (P <.05). Results: Control and Qs implants showed a significant increase of the insertion torque (P <.001). For the resonance frequency, Wc and (control) implants had the greatest ISQ values. However, there's no significant difference between (control) and Qs for the ISQ values (P <.001). Conclusion: Within the limitations of the present study, the proposed geometries at the apical third of dental implants greatly influenced its insertion torque and primary stability in vitro. | en |
| dc.description.affiliation | Department of Diagnosis and Surgery Araraquara Dental School Unesp – Univ Estadual Paulista | |
| dc.description.affiliation | Department of Dental Materials and Prosthodontics Araraquara Dental School Unesp – Univ Estadual Paulista | |
| dc.description.affiliationUnesp | Department of Diagnosis and Surgery Araraquara Dental School Unesp – Univ Estadual Paulista | |
| dc.description.affiliationUnesp | Department of Dental Materials and Prosthodontics Araraquara Dental School Unesp – Univ Estadual Paulista | |
| dc.format.extent | 274-279 | |
| dc.identifier | http://dx.doi.org/10.1111/cid.12574 | |
| dc.identifier.citation | Clinical Implant Dentistry and Related Research, v. 20, n. 3, p. 274-279, 2018. | |
| dc.identifier.doi | 10.1111/cid.12574 | |
| dc.identifier.issn | 1708-8208 | |
| dc.identifier.issn | 1523-0899 | |
| dc.identifier.scopus | 2-s2.0-85048635865 | |
| dc.identifier.uri | http://hdl.handle.net/11449/176463 | |
| dc.language.iso | eng | |
| dc.relation.ispartof | Clinical Implant Dentistry and Related Research | |
| dc.relation.ispartofsjr | 1,827 | |
| dc.rights.accessRights | Acesso restrito | pt |
| dc.source | Scopus | |
| dc.subject | dental implant | |
| dc.subject | implant design | |
| dc.subject | insertion torque | |
| dc.subject | primary stability | |
| dc.subject | resonance frequency analysis | |
| dc.title | Evaluation of primary stability in modified implants: Analysis by resonance frequency and insertion torque | en |
| dc.type | Artigo | pt |
| dspace.entity.type | Publication | |
| relation.isDepartmentOfPublication | 3936e2e2-946a-42ab-8b9d-9521513200fc | |
| relation.isDepartmentOfPublication.latestForDiscovery | 3936e2e2-946a-42ab-8b9d-9521513200fc | |
| relation.isOrgUnitOfPublication | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
| unesp.author.orcid | 0000-0002-0170-2405[1] | |
| unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
| unesp.department | Diagnóstico e Cirurgia - FOAR | pt |
| unesp.department | Materiais Odontológicos e Prótese - FOAR | pt |

