Comparative analysis for reactive energy measurement methodologies, under non-sinusoidal conditions in three-phase four-wire circuits

dc.contributor.authorFazio Jr., Alírio [UNESP]
dc.contributor.authorSampaio, Leonardo P. [UNESP]
dc.contributor.authorDe Brito, Moacyr A.G. [UNESP]
dc.contributor.authorE Melo, Guilherme A. [UNESP]
dc.contributor.authorCanesin, Carlos A. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:26:21Z
dc.date.available2014-05-27T11:26:21Z
dc.date.issued2011-12-28
dc.description.abstractThis paper presents some methodologies for reactive energy measurement, considering three modern power theories that are suitable for three-phase four-wire non-sinusoidal and unbalanced circuits. The theories were applied in some profiles collected in electrical distribution systems which have real characteristics for voltages and currents measured by commercial reactive energy meters. The experimental results are presented in order to analyze the accuracy of the methodologies, considering the standard IEEE 1459-2010 as a reference. Finally, for additional comparisons, the theories will be confronted with the modern Yokogawa WT3000 energy meter and three samples of a commercial energy meter through an experimental setup. © 2011 IEEE.en
dc.description.affiliationSão Paulo State University - UNESP Power Electronics Laboratory Electrical Engineering Department, Av. Prof. José Carlos Rossi, 1370, 15385-000, Ilha Solteira, SP
dc.description.affiliationUnespSão Paulo State University - UNESP Power Electronics Laboratory Electrical Engineering Department, Av. Prof. José Carlos Rossi, 1370, 15385-000, Ilha Solteira, SP
dc.format.extent494-501
dc.identifierhttp://dx.doi.org/10.1109/COBEP.2011.6085277
dc.identifier.citationCOBEP 2011 - 11th Brazilian Power Electronics Conference, p. 494-501.
dc.identifier.doi10.1109/COBEP.2011.6085277
dc.identifier.lattes6427185658143370
dc.identifier.scopus2-s2.0-84255208881
dc.identifier.urihttp://hdl.handle.net/11449/73101
dc.language.isoeng
dc.relation.ispartofCOBEP 2011 - 11th Brazilian Power Electronics Conference
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectMeasurement Errors for Reactive Energy
dc.subjectModern Power Theories
dc.subjectNon-linear Loads
dc.subjectReactive Power
dc.subjectThree-phase Four-wire Circuits
dc.subjectUnbalanced Circuits
dc.subjectCommercial energy
dc.subjectComparative analysis
dc.subjectElectrical distribution system
dc.subjectEnergy measurements
dc.subjectEnergy meters
dc.subjectExperimental setup
dc.subjectNon-sinusoidal
dc.subjectNonlinear load
dc.subjectPower theory
dc.subjectThree-phase four-wire
dc.subjectUnbalanced circuit
dc.subjectYokogawa
dc.subjectElectric measuring instruments
dc.subjectElectric wiring
dc.subjectMeasurement errors
dc.subjectPower electronics
dc.subjectReactive power
dc.subjectWire
dc.subjectElectric network analysis
dc.titleComparative analysis for reactive energy measurement methodologies, under non-sinusoidal conditions in three-phase four-wire circuitsen
dc.typeTrabalho apresentado em evento
dcterms.licensehttp://www.ieee.org/publications_standards/publications/rights/rights_policies.html
dspace.entity.typePublication
unesp.author.lattes6427185658143370[5]
unesp.author.orcid0000-0003-3853-5994[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteirapt
unesp.departmentEngenharia Elétrica - FEISpt

Arquivos