Logotipo do repositório
 

Publicação:
Influence of the power level of an ultra-sonic system on dental cavity preparation

dc.contributor.authorJosgrilberg, Érika Botelho [UNESP]
dc.contributor.authorGuimarães, Murilo de Sousa [UNESP]
dc.contributor.authorPansani, Cyneu Aguiar [UNESP]
dc.contributor.authorCordeiro, Rita de Cássia Loiola [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:22:45Z
dc.date.available2014-05-27T11:22:45Z
dc.date.issued2007-12-31
dc.description.abstractThe aim of this study was to evaluate the shape of dental cavities made with the CVDentus® system using different ultrasound power levels. One standard cavity was made on the buccal aspect of 15 bovine incisors with a CVDentus® cylindrical bur (82142). The sample was divided into three groups: G1 - ultrasound with power II; G2 - ultrasound with power III; and G3 - ultrasound with power IV. A standardizing device was used to obtain standardized preparations and ultrasound was applied during one minute in each dental preparation. The cavities were sectioned in the middle, allowing observation of the cavity's profile with a magnifying glass, and width and depth measurement using the Leica Qwin program. The Kruskal-Wallis (p < 0.05) and Dunn statistical analyses demonstrated differences between the dental cavity shapes when powers III and IV were used. However, the cavities that were made with power III presented dimensions similar to those of the bur used for preparation. We concluded that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.en
dc.description.affiliationDepartment of Pediatrics School of Dentistry of Araraquara São Paulo State University, São Paulo
dc.description.affiliationDepartamento de Clínica Infantil, R. Humaitá 1680, Araraquara, SP 14801-903
dc.description.affiliationUnespDepartment of Pediatrics School of Dentistry of Araraquara São Paulo State University, São Paulo
dc.format.extent362-367
dc.identifierhttp://dx.doi.org/10.1590/S1806-83242007000400014
dc.identifier.citationBrazilian Oral Research, v. 21, n. 4, p. 362-367, 2007.
dc.identifier.doi10.1590/S1806-83242007000400014
dc.identifier.file2-s2.0-37349090111.pdf
dc.identifier.issn1806-8324
dc.identifier.issn1807-3107
dc.identifier.lattes4547405911634315
dc.identifier.lattes8185082796673527
dc.identifier.scieloS1806-83242007000400014
dc.identifier.scopus2-s2.0-37349090111
dc.identifier.urihttp://hdl.handle.net/11449/70225
dc.language.isoeng
dc.relation.ispartofBrazilian Oral Research
dc.relation.ispartofjcr1.223
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectDental cavity preparation
dc.subjectDiamond
dc.subjectTechnology, dental
dc.subjectUltrasonography
dc.subjectdiamond
dc.subjectanimal
dc.subjectcattle
dc.subjectclinical trial
dc.subjectcontrolled clinical trial
dc.subjectcontrolled study
dc.subjectdental surgery
dc.subjectechography
dc.subjectequipment design
dc.subjectinstrumentation
dc.subjectmethodology
dc.subjectnonparametric test
dc.subjectrandomized controlled trial
dc.subjectsurface property
dc.subjecttooth pulp
dc.subjectultrasound therapy
dc.subjectAnimals
dc.subjectCattle
dc.subjectDental Cavity Preparation
dc.subjectDental Pulp Cavity
dc.subjectEquipment Design
dc.subjectStatistics, Nonparametric
dc.subjectSurface Properties
dc.subjectUltrasonic Therapy
dc.titleInfluence of the power level of an ultra-sonic system on dental cavity preparationen
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/bor/paboutj.htm
dspace.entity.typePublication
unesp.author.lattes4547405911634315
unesp.author.lattes8185082796673527
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentClínica Infantil - FOARpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-37349090111.pdf
Tamanho:
188.06 KB
Formato:
Adobe Portable Document Format