Publicação:
Evaluation of Bi as internal standard to minimize matrix effects on the direct determination of Pb in vinegar by graphite furnace atomic absorption spectrometry using Ru permanent modifier with co-injection of Pd/Mg(NO3)(2)

dc.contributor.authorde Oliveira, Silvana Ruella
dc.contributor.authorGomes Neto, José Anchieta [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:24:46Z
dc.date.available2014-05-20T15:24:46Z
dc.date.issued2007-09-01
dc.description.abstractBismuth was evaluated as an internal standard for the direct determination of Pb in vinegar by graphite furnace atomic absorption spectrometry using Ru as a permanent modifier with co-injection of Pd/Mg(NO3)(2). The correlation coefficient of the graph plotted from the non-nalized absorbance signals of Bi versus Pb was r=0.989. Matrix effects were evaluated by analyzing the slope ratios between the analytical curve, and analytical curves obtained from Pb additions in red and white wine vinegar obtained from reference solutions prepared in 0.2% (v/v) HNO3, samples. The calculated ratios were around 1.04 and 1.02 for analytical curves established applying an internal standard and 1.3 and 1.5 for analvtical curves without. Analytical curves in the 2.5-15 pg L-1 Pb concentration interval were established using the ratio Pb absorbance to Bi absorbance versus analvte concentration, and typical linear correlations of r=0.999 were obtained. The proposed method was applied for direct determination of Pb in 18 commercial vinegar samples and the Pb concentration varied from 2.6 to 31 pg L-1. Results were in agreement at a 95% confidence level (paired t-test) with those obtained for digested samples. Recoveries of Pb added to vinegars varied from 96 to 108% with and from 72 to 86% without an internal standard. Two water standard reference materials diluted in vinegar sample were also analyzed and results were in agreement with certified values at a 95% confidence level. The characteristic mass was 40 pg Pb and the useful lifetime of the tube was around 1600 firings. The limit of detection was 0.3 mu g L-1 and the relative standard deviation was <= 3.8% and <= 8.3% (n = 12) for a sample containing, 10 mu L-1 Pb with and without internal standard, respectively. (C) 2007 Elsevier B.V. All rights reserved.en
dc.description.affiliationUniv Estadual Paulista, Dept Quim Anal, BR-14801 Araraquara, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Dept Quim Anal, BR-14801 Araraquara, SP, Brazil
dc.format.extent1046-1050
dc.identifierhttp://dx.doi.org/10.1016/j.sab.2007.06.007
dc.identifier.citationSpectrochimica Acta Part B-atomic Spectroscopy. Oxford: Pergamon-Elsevier B.V., v. 62, n. 9, p. 1046-1050, 2007.
dc.identifier.doi10.1016/j.sab.2007.06.007
dc.identifier.issn0584-8547
dc.identifier.lattes8708735699846578
dc.identifier.urihttp://hdl.handle.net/11449/35316
dc.identifier.wosWOS:000250181900022
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofSpectrochimica Acta Part B-atomic Spectroscopy
dc.relation.ispartofjcr2.854
dc.relation.ispartofsjr0,960
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectleadpt
dc.subjectvinegarpt
dc.subjectgraphite furnace atomic absorption spectrometrypt
dc.subjectBismuth internal standardpt
dc.subjectRU permanent modifierpt
dc.titleEvaluation of Bi as internal standard to minimize matrix effects on the direct determination of Pb in vinegar by graphite furnace atomic absorption spectrometry using Ru permanent modifier with co-injection of Pd/Mg(NO3)(2)en
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
unesp.author.lattes8708735699846578
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: