Logotipo do repositório

Strain Gauge Analysis of the Effect of Porcelain Firing Simulation on the Prosthetic Misfit of Implant-Supported Frameworks

dc.contributor.authorDe Vasconcellos, Diego Klee
dc.contributor.authorOezcan, Mutlu
dc.contributor.authorMaziero Volpato, Claudia Angela
dc.contributor.authorBottino, Marco Antonio [UNESP]
dc.contributor.authorYener, Esra Salihoglu
dc.contributor.institutionUniv Zurich
dc.contributor.institutionUniversidade Federal de Santa Catarina (UFSC)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniv Yeditepe
dc.date.accessioned2014-05-20T14:05:04Z
dc.date.available2014-05-20T14:05:04Z
dc.date.issued2012-06-01
dc.description.abstractObjectives: This study investigated the effect of porcelain firing on the misfit of implant-supported frameworks and analyzed the influence of preheat treatment on the dimensional alterations.Materials and Methods: Four external-hex cylindrical implants were placed in polyurethane block. Ten frameworks of screw-retained implant-supported prostheses were cast in Pd-Ag using 2 procedures: (1) control group (CG, n = 5): cast in segments and laser welded; and test group (TG, n = 5): cast in segments, preheated, and laser welded. All samples were subjected to firing to simulate porcelain veneering firing. Strain gauges were bonded around the implants, and microstrain values (mu epsilon = 10(-6)epsilon) were recorded after welding (M1), oxidation cycle (M2), and glaze firing (M3). Data were statistically analyzed (2-way analysis of variance, Bonferroni, alpha = 0.05).Results: The microstrain value in the CG at M3 (475.2 mu epsilon) was significantly different from the values observed at M1 (355.6 mu epsilon) and M2 (413.9 mu epsilon). The values at M2 and M3 in the CG were not statistically different. Microstrain values recorded at different moments (M1: 361.6 mu epsilon/M2: 335.3 mu epsilon/M3: 307.2 mu epsilon) did not show significant difference.Conclusions: The framework misfit deteriorates during firing cycles of porcelain veneering. Metal distortion after porcelain veneering could be controlled by preheat treatment. (Implant Dent 2012;21:225-229)en
dc.description.affiliationUniv Zurich, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Ctr Dent & Oral Med, Dent Mat Unit, CH-8032 Zurich, Switzerland
dc.description.affiliationUniversidade Federal de Santa Catarina (UFSC), Hlth Sci Ctr, Dept Dent, BR-88040900 Florianopolis, SC, Brazil
dc.description.affiliationUNESP São Paulo State Univ, Sao Jose dos Campos Sch Dent, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.description.affiliationUniv Yeditepe, Fac Dent, Dept Prosthodont, Istanbul, Turkey
dc.description.affiliationUnespUNESP São Paulo State Univ, Sao Jose dos Campos Sch Dent, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.format.extent225-229
dc.identifierhttp://dx.doi.org/10.1097/ID.0b013e3182566e59
dc.identifier.citationImplant Dentistry. Philadelphia: Lippincott Williams & Wilkins, v. 21, n. 3, p. 225-229, 2012.
dc.identifier.dimensionspub.1029133645
dc.identifier.doi10.1097/ID.0b013e3182566e59
dc.identifier.issn1056-6163
dc.identifier.issn1538-2982
dc.identifier.lattes9234456003563666
dc.identifier.orcid0000-0002-9623-6098
dc.identifier.orcid0000-0003-0077-3161
dc.identifier.orcid0000-0003-0918-3678
dc.identifier.pmid22614845
dc.identifier.urihttp://hdl.handle.net/11449/22822
dc.identifier.wosWOS:000304318400013
dc.language.isoeng
dc.publisherLippincott Williams & Wilkins
dc.publisherWolters Kluwer
dc.relation.ispartofImplant Dentistry
dc.relation.ispartofjcr1.307
dc.relation.ispartofsjr0,712
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.sourceDimensions
dc.subjectosseointegrationen
dc.subjectstrain gaugeen
dc.subjectdental prosthesis designen
dc.titleStrain Gauge Analysis of the Effect of Porcelain Firing Simulation on the Prosthetic Misfit of Implant-Supported Frameworksen
dc.typeArtigopt
dcterms.licensehttp://edmgr.ovid.com/spine/accounts/copyrightTransfer.pdf
dcterms.rightsHolderLippincott Williams & Wilkins
dspace.entity.typePublication
relation.isOrgUnitOfPublicationc73b286a-b5fa-4312-a7ec-62f987e7b514
relation.isOrgUnitOfPublication.latestForDiscoveryc73b286a-b5fa-4312-a7ec-62f987e7b514
unesp.author.lattes9234456003563666
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentMateriais Odontológicos e Prótese - ICTpt

Arquivos