Logotipo do repositório

Avaliação dos efeitos de diferentes filtros de realce em imagens radiográficas digitais por parâmetros radiômicos obtidos pela técnica de análise de textura: estudo in vitro

dc.contributor.advisorLopes, Sergio Lúcio Pereira de Castro [UNESP]
dc.contributor.authorTita, Lucas Tavares
dc.contributor.coadvisorSantos, Lana Ferreira
dc.contributor.committeeMemberCarvalho, Cláudio Antonio Talge [UNESP]
dc.contributor.committeeMemberCaneppele, Taciana Marco Ferraz [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)pt
dc.date.accessioned2026-11-03T14:33:39Z
dc.date.issued2026-10-23
dc.description.abstractObjetivo: Analisar, por meio da radiômica baseada em análise de textura (AT), os efeitos de diferentes filtros de realce em imagens radiográficas digitais. Material e métodos: Foram obtidas imagens de um phantom com escala de alumínio, utilizando sistema radiográfico digital de placas de fósforo e aparelho radiográfico intrabucal, em quatro tempos de exposição (0,10 s; 0,16 s; 0,20 s; 0,25 s), com 10 repetições por condição. No software DBSWIN, foram aplicados os filtros Fine (F), Cárie 1 (C1), Cárie 2 (C2), Periodontia (P), Endodontia (E) e High Definition (HD), além do grupo sem filtro. As imagens foram analisadas no MaZda 4.6, em regiões de interesse nos degraus de 0,5 mm, 1,5 mm e 2,5 mm. Foram extraídos 11 parâmetros de textura baseados na matriz de coocorrência, analisados por ANOVA fatorial e teste de Tukey, com nível de significância de 5%. Resultados: Os filtros modificaram significativamente os parâmetros de textura. O Fine apresentou maiores valores de AngScMom e InvDfMom e menores valores de parâmetros relacionados à entropia, indicando maior uniformidade e homogeneidade. O HD apresentou, de modo geral, maiores valores de Contrast, SumOfSqs, SumVarnc, SumEntrp, Entropy, DifVarnc e DifEntrp, e menores valores de AngScMom e InvDfMom, indicando maior variação, dispersão e desordem dos tons de cinza. Os efeitos variaram conforme a exposição e a espessura. Conclusão: Os filtros de realce alteram quantitativamente o comportamento textural das imagens radiográficas digitais, reforçando a necessidade de padronização no uso clínico e científico.pt
dc.description.abstractObjective: To analyze, using radiomics based on texture analysis (TA), the effects of different enhancement filters on digital radiographic images. Materials and Methods: Images of an aluminum step-wedge phantom were obtained using a digital phosphor plate radiographic system and an intraoral X-ray unit at four exposure times (0.10 s, 0.16 s, 0.20 s, and 0.25 s), with 10 repetitions per condition. In DBSWIN software, the Fine (F), Caries 1 (C1), Caries 2 (C2), Periodontology (P), Endodontics (E), and High Definition (HD) filters were applied, in addition to an unfiltered group. The images were analyzed in MaZda 4.6 using regions of interest positioned on the 0.5 mm, 1.5 mm, and 2.5 mm steps. Eleven texture parameters based on the gray-level co-occurrence matrix were extracted and analyzed using factorial ANOVA and Tukey’s test, with a 5% significance level. Results: The filters significantly modified the texture parameters. Fine showed higher AngScMom and InvDfMom values and lower values for entropyrelated parameters, indicating greater uniformity and homogeneity. HD generally showed higher Contrast, SumOfSqs, SumVarnc, SumEntrp, Entropy, DifVarnc, and DifEntrp values and lower AngScMom and InvDfMom values, indicating greater variation, dispersion, and disorder in gray levels. The effects varied according to exposure time and thickness. Conclusion: Enhancement filters quantitatively alter the textural behavior of digital radiographic images, reinforcing the need for standardization in clinical and research use.en
dc.identifier.lattes0825970971999492
dc.identifier.orcid0000-0003-3840-5401
dc.identifier.urihttps://hdl.handle.net/11449/349532
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (UNESP)pt
dc.rights.accessRightsAcesso restritopt
dc.subjectProcessamento de imagem assistida por computadorpt
dc.subjectRadiografia dentáriapt
dc.subjectRadiômicapt
dc.subjectImage processing, computer-assisteden
dc.subjectRadiography, Dentaen
dc.subjectRadiomicsen
dc.titleAvaliação dos efeitos de diferentes filtros de realce em imagens radiográficas digitais por parâmetros radiômicos obtidos pela técnica de análise de textura: estudo in vitropt
dc.title.alternativeEvaluation of the effects of different enhancement filters on digital radiographic images using radiomic parameters obtained through texture analysis: an in vitro studyen
dc.typeTrabalho de conclusão de cursopt
dspace.entity.typePublication
relation.isAuthorOfPublication81c56acb-33fb-4cdd-a668-30de8d1bf85a
relation.isAuthorOfPublication.latestForDiscovery81c56acb-33fb-4cdd-a668-30de8d1bf85a
relation.isCoadvisorOfPublicationd85551c9-3b70-4a17-8ca9-c93b9d986b44
relation.isCoadvisorOfPublication.latestForDiscoveryd85551c9-3b70-4a17-8ca9-c93b9d986b44
relation.isOrgUnitOfPublicationc73b286a-b5fa-4312-a7ec-62f987e7b514
relation.isOrgUnitOfPublication.latestForDiscoveryc73b286a-b5fa-4312-a7ec-62f987e7b514
relation.isUndergradCourseOfPublicationc86586bc-e5d3-4667-8f24-bf8eb0f2ab80
relation.isUndergradCourseOfPublication.latestForDiscoveryc86586bc-e5d3-4667-8f24-bf8eb0f2ab80
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.examinationboard.typeBanca públicapt
unesp.undergraduateSão José dos Campos - ICT - Odontologiapt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
tita_lt_tcc_sjc.pdf
Tamanho:
1,25 MB
Formato:
Adobe Portable Document Format