Logotipo do repositório
 

Publicação:
Calibration strategies applied to laser-induced breakdown spectroscopy: A critical review of advances and challenges

dc.contributor.authorCosta, Vinicius C.
dc.contributor.authorBabos, Diego V.
dc.contributor.authorCastro, Jeyne P.
dc.contributor.authorAndrade, Daniel F.
dc.contributor.authorGamela, Raimundo R.
dc.contributor.authorMacHado, Raquel C.
dc.contributor.authorSperanca, Marco A. [UNESP]
dc.contributor.authorAraujo, Alisson S.
dc.contributor.authorGarcia, Jose A.
dc.contributor.authorPereira-Filho, Edenir R.
dc.contributor.institutionUniversidade Federal do Espírito Santo (UFES)
dc.contributor.institutionUniversidade Federal de Saõ Carlos
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2021-06-25T10:12:08Z
dc.date.available2021-06-25T10:12:08Z
dc.date.issued2020-01-01
dc.description.abstractOver the years, laser-induced breakdown spectroscopy (LIBS) has been reported in the literature as an alternative to traditional methods of analysis, becoming well established among spectroanalytical techniques. LIBS is a technique widely used for qualitative approaches; however, it is necessary considerable effort for use in quantitative analysis, mainly due to severe matrix effects. These limitations make it difficult to broaden the application of LIBS in quantitative analysis. In this sense, this review discusses recent advances in calibration strategies applied in LIBS for minimizing matrix effects and enabling determination with satisfactory accuracy and precision. Applications, advantages, and limitations of the calibration strategies, such as matrix-matching calibration (MMC), internal standardization (IS), standard addition (SA), multi-energy calibration (MEC), one-point gravimetric standard addition (OP GSA), one-point and multi-line calibration (OP MLC), slope ratio calibration (SRC), two-point calibration transfer (TP CT), single-sample calibration (SSC), multiple linear regression (MLR), principal component regression (PCR), partial least squares (PLS) and artificial neural networks (ANN) are discussed.en
dc.description.affiliationLaboratório de Espectrometria Atômica (LEA) LabPetro Departamento de Química Universidade Federal Do Espírito Santo
dc.description.affiliationGrupo de Análise Instrumental Aplicada Departamento de Química Universidade Federal de Saõ Carlos
dc.description.affiliationGrupo de Abordagens Analíticas Alternativas (GAAA) Instituto de Pesquisa em Bioenergia (IPBEN) Instituto de Química Universidade Estadual Paulista (Unesp)
dc.description.affiliationUnespGrupo de Abordagens Analíticas Alternativas (GAAA) Instituto de Pesquisa em Bioenergia (IPBEN) Instituto de Química Universidade Estadual Paulista (Unesp)
dc.format.extent2439-2451
dc.identifierhttp://dx.doi.org/10.21577/0103-5053.20200175
dc.identifier.citationJournal of the Brazilian Chemical Society, v. 31, n. 12, p. 2439-2451, 2020.
dc.identifier.doi10.21577/0103-5053.20200175
dc.identifier.fileS0103-50532020001202439.pdf
dc.identifier.issn1678-4790
dc.identifier.issn0103-5053
dc.identifier.scieloS0103-50532020001202439
dc.identifier.scopus2-s2.0-85091769735
dc.identifier.urihttp://hdl.handle.net/11449/205237
dc.language.isoeng
dc.relation.ispartofJournal of the Brazilian Chemical Society
dc.rights.accessRightsAcesso abertopt
dc.sourceScopus
dc.subjectCalibration strategies
dc.subjectLIBS
dc.subjectMatrix effects
dc.subjectQuantitative analysis
dc.titleCalibration strategies applied to laser-induced breakdown spectroscopy: A critical review of advances and challengesen
dc.typeArtigopt
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Pesquisa em Bioenergia, Rio Claropt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0103-50532020001202439.pdf
Tamanho:
1.28 MB
Formato:
Adobe Portable Document Format