Logotipo do repositório
 

Publicação:
Deformation of Implant Abutments After Framework Connection Using Strain Gauges

dc.contributor.authorHollweg, Henrique
dc.contributor.authorJacques, Leticia Borges
dc.contributor.authorMoura, Marcio da Silva [UNESP]
dc.contributor.authorBianco, Vinicius Cappo
dc.contributor.authorSousa, Edson Antonio Capello [UNESP]
dc.contributor.authorRubo, Jose Henrique
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal de Santa Maria (UFSM)
dc.date.accessioned2014-05-20T13:27:24Z
dc.date.available2014-05-20T13:27:24Z
dc.date.issued2012-04-01
dc.description.abstractWhen a cylinder is connected to an abutment it is expected that abutment and cylinder will be subjected to compression forces throughout their periphery because of the clamping force exerted by the screw. The deformation resultant of this compression should be measurable and uniform along the periphery of the abutment. Considering that multiple retainers connected to each other can affect the fit of a framework, as well as the use of different alloys, it is expected that the abutments will present different levels of deformation as a result of framework connection. The aim of this study was to evaluate the deformation of implant abutments after frameworks, cast either in cobalt-chromium (CoCr) or silver-palladium (AgPd) alloys, were connected. Samples (n = 5) simulating a typical mandibular cantilevered implant-supported prosthesis framework were fabricated in cobalt-chromium and silver-palladium alloys and screwed onto standard abutments positioned on a master-cast containing 5 implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation as the retention screws were tightened. A combination of compressive and tensile forces was observed on the abutments for both CoCr and AgPd frameworks. There was no evidence of significant differences in median abutment deformation levels for 9 of the 10 abutment aspects. Visually well-fit frameworks do not necessarily transmit load uniformly to abutments. The use of CoCr alloy for implant-supported prostheses frameworks may be as clinically acceptable as AgPd alloy.en
dc.description.affiliationUniv São Paulo, Bauru Sch Dent, Dept Prosthodont, Bauru, SP, Brazil
dc.description.affiliationSão Paulo State Univ, Bauru, SP, Brazil
dc.description.affiliationUniversidade Federal de Santa Maria (UFSM), Dept Restorat Dent, Sch Dent, BR-97119900 Santa Maria, RS, Brazil
dc.description.affiliationSão Paulo State Univ, Dept Mech Engn, Sch Engn, Bauru, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Bauru, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Dept Mech Engn, Sch Engn, Bauru, SP, Brazil
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdCNPq: 300666/93-4
dc.description.sponsorshipIdFAPESP: 99/01402-6
dc.description.sponsorshipIdFAPESP: 05/56182-3
dc.format.extent125-132
dc.identifierhttp://dx.doi.org/10.1563/AAID-JOI-D-10-00068
dc.identifier.citationJournal of Oral Implantology. Lawrence: Allen Press Inc, v. 38, n. 2, p. 125-132, 2012.
dc.identifier.doi10.1563/AAID-JOI-D-10-00068
dc.identifier.issn0160-6972
dc.identifier.lattes8934648262859482
dc.identifier.urihttp://hdl.handle.net/11449/8988
dc.identifier.wosWOS:000304074600004
dc.language.isoeng
dc.publisherAllen Press Inc
dc.relation.ispartofJournal of Oral Implantology
dc.relation.ispartofjcr1.212
dc.relation.ispartofsjr0,569
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectimplant frameworksen
dc.subjectprosthesis fiten
dc.subjectstrain gaugesen
dc.titleDeformation of Implant Abutments After Framework Connection Using Strain Gaugesen
dc.typeArtigo
dcterms.licensehttp://www.joionline.org/userimages/ContentEditor/1240858717108/Terms_and_Conditions_ORIM1.pdf
dcterms.rightsHolderAllen Press Inc
dspace.entity.typePublication
unesp.author.lattes8934648262859482
unesp.author.orcid0000-0003-1595-845X[6]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Baurupt
unesp.departmentEngenharia Mecânica - FEBpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: