Logotipo do repositório

Comparison of compressive forces generated by dynamic compression angle-stable interlocking nail versus traditional dynamic compression plate and locking compression plate

dc.contributor.authorMalta, Caio Afonso Santos [UNESP]
dc.contributor.authorCarrera, Alefe Luiz Caliani [UNESP]
dc.contributor.authorRocha, Thiago André Salvitti Sá
dc.contributor.authorMinto, Bruno Watanabe [UNESP]
dc.contributor.authorDias, Luís Gustavo Gosuen Gonçalves
dc.date.accessioned2026-06-09T18:48:15Z
dc.date.issued2025-09-03
dc.description.abstractThe aim of this study was to compare the compressive forces generated by Dynamic Compression Angle-Stable Interlocking Nail (DCASIN) with those of traditional Dynamic Compression Plates (DCP) and Locking Compression Plates (LCP) using synthetic diaphyseal bone models (SDBM). Three groups were established based on the fixation method (G-DCASIN, G-DCP, and G-LCP), with implants fixed to SDBM simulating a transverse fracture, comprising 10 repetitions per group. A strain-gauge load cell was positioned in the SDBM gap to measure compressive forces in kilograms, recorded 30 s after the completion of each group-specific compression technique. For G-DCASIN, the proximal SDBM was compressed against the load cell using the external implantation guide and compression device. For G-DCP and G-LCP, the same-side double loading technique was applied to the proximal SDBM. Compressive forces among groups were compared using the Kruskal-Wallis test followed by Dunn's post-hoc analysis. The mean compressive forces recorded for G-DCASIN, G-DCP, and G-LCP were 22.56 ± 5.1 kg, 27.28 ± 1.86 kg, and 11.65 ± 1.69 kg, respectively. Both G-DCASIN and G-DCP exhibited significantly greater compressive forces compared to G-LCP (p = 0.0013 and p < 0.0001, respectively), whereas G-DCASIN and G-DCP did not differ significantly (p = 0.2228). In this mechanical trial, DCASIN demonstrated the ability to generate interfragmentary compression superior to LCP and comparable to DCP. The combination of compressive capability and angle-stable locking suggests that this model may be a viable option for the treatment of transverse fractures of long bones.
dc.description.affiliationDepartment of Clinical and Veterinary Surgery, School of Agricultural and Veterinary Sciences, "Júlio de Mesquita Filho" São Paulo State University - UNESP, Jaboticabal, State of São Paulo, Brazil.
dc.description.affiliationDepartment of Clinical and Veterinary Surgery, School of Agricultural and Veterinary Sciences, "Júlio de Mesquita Filho" São Paulo State University - UNESP, Jaboticabal, State of São Paulo, Brazil. Electronic address: alefe.carrera@gmail.com.
dc.description.affiliationDepartment of Veterinary Medicine, Federal University of Jatai (UFJ), Jataí, State of Goiás, Brazil.
dc.description.affiliationUnespDepartment of Clinical and Veterinary Surgery, School of Agricultural and Veterinary Sciences, "Júlio de Mesquita Filho" São Paulo State University - UNESP, Jaboticabal, State of São Paulo, Brazil.
dc.description.affiliationUnespDepartment of Clinical and Veterinary Surgery, School of Agricultural and Veterinary Sciences, "Júlio de Mesquita Filho" São Paulo State University - UNESP, Jaboticabal, State of São Paulo, Brazil. Electronic address: alefe.carrera@gmail.com.
dc.identifierhttps://app.dimensions.ai/details/publication/pub.1192587958
dc.identifier.dimensionspub.1192587958
dc.identifier.doi10.1016/j.rvsc.2025.105881
dc.identifier.issn0034-5288
dc.identifier.issn1532-2661
dc.identifier.orcid0000-0003-4910-6861
dc.identifier.orcid0000-0003-3558-2664
dc.identifier.orcid0000-0003-1414-3101
dc.identifier.orcid0000-0002-8808-4127
dc.identifier.pmid40914140
dc.identifier.urihttps://hdl.handle.net/11449/325237
dc.publisherElsevier
dc.relation.ispartofResearch in Veterinary Science; v. 196; p. 105881
dc.rights.accessRightsAcesso restritopt
dc.rights.sourceRightsclosed
dc.sourceDimensions
dc.titleComparison of compressive forces generated by dynamic compression angle-stable interlocking nail versus traditional dynamic compression plate and locking compression plate
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublication3d807254-e442-45e5-a80b-0f6bf3a26e48
relation.isOrgUnitOfPublication.latestForDiscovery3d807254-e442-45e5-a80b-0f6bf3a26e48
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências Agrárias e Veterinárias, Jaboticabalpt

Arquivos