Logotipo do repositório
 

Publicação:
Effect of the interfacial area measurement parameters on the push-out strength between fiber post and dentin

dc.contributor.authorBergoli, Cesar Dalmolin [UNESP]
dc.contributor.authorCosta Lima, Julia Magalhaes da [UNESP]
dc.contributor.authorMelo, Renata Marques de [UNESP]
dc.contributor.authorBottino, Marco Antonio [UNESP]
dc.contributor.authorValandro, Luiz Felipe
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal de Sergipe (UFS)
dc.date.accessioned2014-12-03T13:11:11Z
dc.date.available2014-12-03T13:11:11Z
dc.date.issued2014-04-01
dc.description.abstractPurpose: To verify the influence of different instruments and operators on the bonding interfacial area and on the push-out bond strength values.Material and methods: Fifteen anterior human teeth (n=15) were selected, cleaned and standardized to 15 mm length. Root canals were prepared in 12 mm and the fiber posts were cemented using the RelyX U-100 cement. Three slices were obtained per tooth (N=45) and submitted to the push-out bond strength test. The bonding interfacial area (mm(2)) of each specimen was calculated based on the disc slice dimensions: coronal and apical diameter and height. The bonding area of each specimen was used to calculate the bond strength (Mpa). The dimensions were analyzed by different operators, using two instruments: G1 - Operator A with a digital caliper; G2 - Operator A with a stereomicroscope; G3 - Operator B with a digital caliper; G4 - Operator B with a digital stereomicroscope; G5 - Operator C with a digital caliper; G6 - Operator C with a stereomicroscope. The mean area was submitted to inter-operator and intra-operator analyses, while the mean area and mean of bond strength were submitted to the 2-way ANOVA with repeated measures and the Tukey test (alpha=0.05).Results: The inter-operator kappa was 0.83 to the digital caliper and 0.91 to the stereomicroscope, while the intra-operator kappa was 0.76. The operator and the measurement instrument influenced the interfacial bonding area (p=0.000 and p=0.001) and the push-out bond strength values (p=0.000 and p=0.000, respectively) of the disc slices.Conclusion: The final push-out bond strength values are influenced by the measuring instrument and by the measurer operator. (C) 2014 Published by Elsevier Ltd.en
dc.description.affiliationSao Paulo State Univ UNESP, Sao Jose Campos Dent Sch, BR-12245000 Sao Paulo, Brazil
dc.description.affiliationSao Paulo State Univ UNESP, Sao Jose Campos Dent Sch, Dept Dent Mat & Prosthodont, BR-12245000 Sao Paulo, Brazil
dc.description.affiliationUniv Fed Santa Maria, Fac Odontol, Prosthodont Unit, BR-97015372 Santa Maria, RS, Brazil
dc.description.affiliationUnespSao Paulo State Univ UNESP, Sao Jose Campos Dent Sch, BR-12245000 Sao Paulo, Brazil
dc.description.affiliationUnespSao Paulo State Univ UNESP, Sao Jose Campos Dent Sch, Dept Dent Mat & Prosthodont, BR-12245000 Sao Paulo, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 11/09897-8
dc.format.extent7-10
dc.identifierhttp://dx.doi.org/10.1016/j.ijadhadh.2013.12.024
dc.identifier.citationInternational Journal Of Adhesion And Adhesives. Oxford: Elsevier Sci Ltd, v. 50, p. 7-10, 2014.
dc.identifier.doi10.1016/j.ijadhadh.2013.12.024
dc.identifier.issn0143-7496
dc.identifier.lattes9234456003563666
dc.identifier.urihttp://hdl.handle.net/11449/112964
dc.identifier.wosWOS:000334139700002
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofInternational Journal of Adhesion and Adhesives
dc.relation.ispartofjcr2.065
dc.relation.ispartofsjr0,926
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectFiber posten
dc.subjectCompositeen
dc.subjectMicroscopyen
dc.subjectBond strengthen
dc.titleEffect of the interfacial area measurement parameters on the push-out strength between fiber post and dentinen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
unesp.author.lattes9234456003563666
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentMateriais Odontológicos e Prótese - ICTpt

Arquivos