Logo do repositório
 

Efeito de oxigênio na biocompatibilidade e propriedades da liga Ti-15Mo

dc.contributor.advisorGrandini, Carlos Roberto [UNESP]
dc.contributor.authorMartins Júnior, José Roberto Severino [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-06-11T19:30:19Z
dc.date.available2014-06-11T19:30:19Z
dc.date.issued2010-09-23
dc.description.abstractDesde 1970, o titânio e algumas de suas ligas são vastamente usados na fabrição de próteses e dispositivos especiais nas áreas médica e odontológica devido às suas propriedades como baixos valores de módulo de elasticidade (Módulo de Young), resistência à corrosão e características de biocompatibilidade. A presença de elementos intersticiais (oxigênio, carbono, nitrogênio e hidrogênio) altera de maneira significativa as propriedades mecânicas da liga, principalmente suas propriedades elásticas, causando endurecimento ou fragilização da liga. As medidas de espectroscopia mecânica constituem uma ferramenta poderosa para o estudo da interação destes elementos substitucionais e intersticiais com a matriz metálica. O objetivo do trabalho foi prepararA LIGA Ti-15Mo por fusão a arco, e estudar a influência de tratamentos térmicos e do oxigênio presente em solução sólida, na estrutura, propriedades mecânicas, químicas, anelásticas e biocompatibilidade da liga. Os resultados de difração de raios X analisados pelo método de Rietveld permitiram quantificar as fases presentes na microestrutura, estando de acordo com as micrografias obtidas. Os resultados de dureza e módulo de elasticidade mostraram ser sensíveis à concentração de oxigênio e à microestrutura da liga. Nos ensaios de corrosão houve uma melhora significativa do potencial de corrosão após as dopagens com oxigênio. As medidas de espectroscopia mecânica apresentaram estruturas de relaxação e foram identificados os processos constituintes. Os ensaios de biocompatibilidade mostraram que a liga em questão pode ser considerada biocompatívelpt
dc.description.abstractSince 1970, titanium and some of its alloys have been widely used in the manufacture of special devices and prostheses in medical and dental areas due to properties which include low elasticity modulus values, corrosion resistance and characteristics of biocumpatibility. The presence of interstial elements (carbon, nitrogen, oxygen and hydrogen) significantly alters the alloy's mechanical properties, mainly its elastic properties, causing either a hardening or softening of the alloy. Mechanical spectroscopy measurements are a powerful tool to study the interaction of these substitutional and interstitial elements with a metallic matrix. The aim of this work was to prepare the Ti-15Mo alloy by arc-melting and study the influence of heat treatments and oxygen present in the solid solution of the structure, as well as the mechanical, chemical and anelastic properties, and biocompatibility of the alloys. The results of x-ray diffraction were analyzed by the Rietveld Method to allow the phases present in the microestructure to be quantified according to the obtained micrographies. The hardness and elasticity modulus results were sensitive to the oxygen concentration and the alloy microstructure. In corrosion tests there was a significant improvement of the corrosion potential after the oxygen dopyng. The mechanical spectroscopy measurements showed relaxation structures, and constituent relaxation processes were identified. The biocompatibility tests showed that the alloy in question can be considered biocompatibleen
dc.format.extent140 f. : il., tabs.
dc.identifier.aleph000628676
dc.identifier.capes33004056083P7
dc.identifier.citationMARTINS JÚNIOR, José Roberto Severino. Efeito de oxigênio na biocompatibilidade e propriedades da liga Ti-15Mo. 2010. 140 f. Dissertação (mestrado) - Universidade Estadual Paulista, Faculdade de Ciências, 2010.
dc.identifier.filemartinsjunior_jrs_me_bauru.pdf
dc.identifier.lattes2949983867418338
dc.identifier.urihttp://hdl.handle.net/11449/99715
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso abertopt
dc.sourceAleph
dc.subjectLigas de titaniopt
dc.subjectMetais - Tratamento termicopt
dc.subjectOxigeniopt
dc.subjectRietveld, Metodo dept
dc.subjectCorrosãopt
dc.subjectBiocompatibilidadept
dc.subjectBiomateriaispt
dc.subjectBiomaterialsen
dc.subjectTitanium alloysen
dc.subjectHeat treatmenten
dc.subjectInterstitial oxygenen
dc.subjectAnelasticityen
dc.subjectRietveld methoden
dc.subjectCorrosionen
dc.subjectBiocompatibilityen
dc.titleEfeito de oxigênio na biocompatibilidade e propriedades da liga Ti-15Mopt
dc.typeDissertação de mestradopt
dspace.entity.typePublication
unesp.advisor.lattes2949983867418338[1]
unesp.advisor.orcid0000-0002-3336-309X[1]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências, Baurupt
unesp.graduateProgramCiência e Tecnologia de Materiais - FCpt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
martinsjunior_jrs_me_bauru.pdf
Tamanho:
3.28 MB
Formato:
Adobe Portable Document Format