Publicação:
HOW TO EFFICIEN TLY INCORPORATE FACTS DEVICES IN OPTIMAL ACTIVE POWER FLOW MODEL

dc.contributor.authorAzevedo, Anibal T. [UNESP]
dc.contributor.authorOliveira, Aurelio R. L.
dc.contributor.authorRider, Marcos J. [UNESP]
dc.contributor.authorSoares, Secundino
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.date.accessioned2014-05-20T13:29:08Z
dc.date.available2014-05-20T13:29:08Z
dc.date.issued2010-05-01
dc.description.abstractThis paper presents for the first time how to easily incorporate facts devices in an optimal active power flow model such that an efficient interior-point method may be applied. The optimal active power flow model is based on a network flow approach instead of the traditional nodal formulation that allows the use of an efficiently predictor-corrector interior point method speed up by sparsity exploitation. The mathematical equivalence between the network flow and the nodal models is addressed, as well as the computational advantages of the former considering the solution by interior point methods. The adequacy of the network flow model for representing facts devices is presented and illustrated on a small 5-bus system. The model was implemented using Matlab and its performance was evaluated with the 3,397-bus and 4,075-branch Brazilian power system which show the robustness and efficiency of the formulation proposed. The numerical results also indicate an efficient tool for optimal active power flow that is suitable for incorporating facts devices.en
dc.description.affiliationUniv Estadual Paulista, Fac Engn Guaratingueta, Guaratingueta, SP, Brazil
dc.description.affiliationUniv Estadual Campinas, Dept Appl Math, Campinas, SP, Brazil
dc.description.affiliationUniv Estadual Paulista, Fac Engn Ilha Solteira, Dept Elect Engn, Ilha Solteira, SP, Brazil
dc.description.affiliationUniv Estadual Campinas, Elect & Comp Engn Sch, Campinas, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Fac Engn Guaratingueta, Guaratingueta, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Fac Engn Ilha Solteira, Dept Elect Engn, Ilha Solteira, SP, Brazil
dc.format.extent315-331
dc.identifierhttp://dx.doi.org/10.3934/jimo.2010.6.315
dc.identifier.citationJournal of Industrial and Management Optimization. Springfield: Amer Inst Mathematical Sciences, v. 6, n. 2, p. 315-331, 2010.
dc.identifier.doi10.3934/jimo.2010.6.315
dc.identifier.issn1547-5816
dc.identifier.urihttp://hdl.handle.net/11449/9785
dc.identifier.wosWOS:000276414300004
dc.language.isoeng
dc.publisherAmer Inst Mathematical Sciences
dc.relation.ispartofJournal of Industrial and Management Optimization
dc.relation.ispartofjcr0.994
dc.relation.ispartofsjr0,541
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectOptimal active power flowen
dc.subjectfacts devicesen
dc.subjectnetwork flow modelen
dc.subjectinterior point methoden
dc.titleHOW TO EFFICIEN TLY INCORPORATE FACTS DEVICES IN OPTIMAL ACTIVE POWER FLOW MODELen
dc.typeArtigo
dcterms.licensehttp://aimsciences.org/journals/tex-sample/CopyRightAgreement.pdf
dcterms.rightsHolderAmer Inst Mathematical Sciences
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteirapt
unesp.departmentEngenharia Elétrica - FEISpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: