Publicação: Occupational exposure of physical therapists to electric and magnetic fields and the efficacy of Faraday cages
dc.contributor.author | Messias, Iracimara de Anchieta [UNESP] | |
dc.contributor.author | Okuno, Emico | |
dc.contributor.author | Colacioppo, Sergio | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.date.accessioned | 2014-05-20T13:23:36Z | |
dc.date.available | 2014-05-20T13:23:36Z | |
dc.date.issued | 2011-10-01 | |
dc.description.abstract | Objective. Measure physical therapists' exposure to the electric and magnetic fields produced by 17 shortwave diathermy devices in physical therapy clinics in the city of Presidente Prudente, São Paulo State, Brazil. Compare the observed values with the exposure levels recommended by the International Commission on Non-ionizing Radiation Protection (ICNIRP). Observe the efficacy of Faraday cages as a means of protecting physical therapists from exposure to oscillating electric and magnetic fields.Methods. Electric and magnetic field measurements were taken at four points during actual physical therapy sessions: in proximity to the operator's pelvis and head, the devices' electrical cables, and the electrodes. The measuring equipment was a Wandel & Goltermann EMR-200.Results. The values obtained in proximity to the electrodes and cables were 10 to 30 times higher than ICNIRP's recommended occupational reference levels. In the shortwave diathermy treatment rooms with Faraday cages, the fields were even higher than in treatment rooms not so equipped-principally the magnetic field, where the values were more than 100 times higher than the ICNIRP exposure limit.Conclusions. The electric and magnetic field intensities obtained in this study are generally above the exposure levels recommend in ICNIRP standards. It was also observed that the Faraday cage offers physical therapists no protection, and instead, increases their level of exposure. | en |
dc.description.affiliation | Univ Estadual Paulista, Fac Ciencias & Tecnol, São Paulo, Brazil | |
dc.description.affiliation | Univ São Paulo, Inst Fis, BR-01498 São Paulo, Brazil | |
dc.description.affiliation | Univ São Paulo, Fac Saúde Publ, São Paulo, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Fac Ciencias & Tecnol, São Paulo, Brazil | |
dc.format.extent | 309-316 | |
dc.identifier | http://dx.doi.org/10.1590/S1020-49892011001000004 | |
dc.identifier.citation | Revista Panamericana de Salud Publica-pan American Journal of Public Health. Washington: Pan Amer Health Organization, v. 30, n. 4, p. 309-316, 2011. | |
dc.identifier.doi | 10.1590/S1020-49892011001000004 | |
dc.identifier.issn | 1020-4989 | |
dc.identifier.lattes | 1055911386902390 | |
dc.identifier.scielo | S1020-49892011001000004 | |
dc.identifier.uri | http://hdl.handle.net/11449/7138 | |
dc.identifier.wos | WOS:000299527200004 | |
dc.language.iso | por | |
dc.publisher | Pan Amer Health Organization | |
dc.relation.ispartof | Revista Panamericana de Salud Publica - Pan American Journal of Public Health | |
dc.relation.ispartofjcr | 0.784 | |
dc.relation.ispartofsjr | 0,452 | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Web of Science | |
dc.subject | Occupational exposure | en |
dc.subject | radiation, nonionizing | en |
dc.subject | physical therapy | en |
dc.subject | electromagnetic fields | en |
dc.subject | diathermy | en |
dc.subject | short-wave therapy | en |
dc.subject | Brazil | en |
dc.title | Occupational exposure of physical therapists to electric and magnetic fields and the efficacy of Faraday cages | en |
dc.type | Artigo | |
dcterms.license | http://www.scielosp.org/revistas/rpsp/iaboutj.htm | |
dcterms.rightsHolder | Pan Amer Health Organization | |
dspace.entity.type | Publication | |
unesp.author.lattes | 1055911386902390 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Ciências e Tecnologia, Presidente Prudente | pt |
unesp.department | Planejamento, Urbanismo e Ambiente - FCT | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: