Logo do repositório
 

Stress analysis in oral obturator prostheses over parallel and tilted implants: photoelastic imaging

dc.contributor.authorPesqueira, Aldieris Alves [UNESP]
dc.contributor.authorGoiato, Marcelo Coelho [UNESP]
dc.contributor.authorSantos, Daniela Micheline dos [UNESP]
dc.contributor.authorNobrega, Adhara Smith [UNESP]
dc.contributor.authorHaddad, Marcela Filie [UNESP]
dc.contributor.authorAndreotti, Agda Marobo [UNESP]
dc.contributor.authorMoreno, Amalia [UNESP]
dc.contributor.institutionUniversidade do Sagrado Coração (USC)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-12-03T13:10:42Z
dc.date.available2014-12-03T13:10:42Z
dc.date.issued2013-10-01
dc.description.abstractThis study aimed to evaluate the stress distribution through the photoelastic method in implant-retained palatal obturators prostheses. Two photoelastic models with bucco-sinusal communication were fabricated, one model without implants and another with two parallel implants and one tilted in the molar region. A conventional obturator prosthesis and five implant-retained obturators dentures with different attachment systems were fabricated: OR, three individualized O-rings; BC, bar clip; BOC, implants splinted by bars associated with two O-rings positioned at the center of the bar; OD, implants splinted by bars associated with two O-rings positioned in distal cantilever; and BOD, implants splinted by bars with clips associated with two O-rings positioned in distal cantilever. Each assembly (model/attachment system/prosthesis) was positioned in a circular polariscope and a load of 100 N was applied on each implant. The results were obtained by observing the photographic record of the tensions in the photoelastic models resulting from the application of load. It can be observed that a larger amount of stress fringes on BC system. It was concluded that the attachment system has a direct influence on the stress distribution of implant-retained obturator prostheses, with the three individualized O-rings exhibiting the lowest stress values, and tilted implants presented a biomechanical behavior similar to parallel implants. (C) The Authors.en
dc.description.affiliationUniv Sagrado Coracao, Fac Dent, Dept Oral Biol, Sao Paulo, Brazil
dc.description.affiliationUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, Sao Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, Sao Paulo, Brazil
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 10/01241-3
dc.format.extent5
dc.identifierhttp://dx.doi.org/10.1117/1.JBO.18.10.106009
dc.identifier.citationJournal Of Biomedical Optics. Bellingham: Spie-soc Photo-optical Instrumentation Engineers, v. 18, n. 10, 5 p., 2013.
dc.identifier.doi10.1117/1.JBO.18.10.106009
dc.identifier.fileWOS000326563000041.pdf
dc.identifier.issn1083-3668
dc.identifier.lattes9719883814872582
dc.identifier.orcid0000-0002-3800-3050
dc.identifier.urihttp://hdl.handle.net/11449/112439
dc.identifier.wosWOS:000326563000041
dc.language.isoeng
dc.publisherSpie-soc Photo-optical Instrumentation Engineers
dc.relation.ispartofJournal of Biomedical Optics
dc.relation.ispartofjcr2.367
dc.relation.ispartofsjr0,918
dc.rights.accessRightsAcesso abertopt
dc.sourceWeb of Science
dc.subjectdental implantsen
dc.subjectpalatal obturatorsen
dc.subjectmaxillofacial prosthesisen
dc.subjectdental prosthesisen
dc.titleStress analysis in oral obturator prostheses over parallel and tilted implants: photoelastic imagingen
dc.typeArtigopt
dcterms.rightsHolderSpie-soc Photo-optical Instrumentation Engineers
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes9719883814872582
unesp.author.lattes2336450644149867[1]
unesp.author.orcid0000-0002-3800-3050[2]
unesp.author.orcid0000-0003-3020-5253[1]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
WOS000326563000041.pdf
Tamanho:
2.18 MB
Formato:
Adobe Portable Document Format