Logotipo do repositório
 

Publicação:
Determination of cobalt marker in cow ruminal fluid by EDXRF and SRTXRF

dc.contributor.authorde Almeida, Eduardo
dc.contributor.authorMassoni, Paulo Rogerio
dc.contributor.authorMenegario, Amauri Antonio
dc.contributor.authorLeite, Laudi Cunha
dc.contributor.authorDuarte Lanna, Dante Pazzanese
dc.contributor.authordo Nascimento Filho, Virgilio Franco
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:31:08Z
dc.date.available2014-05-20T15:31:08Z
dc.date.issued2011-11-01
dc.description.abstractThis article describes a comparison of conventional energy-dispersive X-ray fluorescence (EDXRF) and synchrotron radiation total-reflection X-ray fluorescence (SRTXRF) for Co determination in ruminal fluid from Holstein cow. This element is used as marker for animal nutrition studies. For EDXRF, 200 mu l of the sample were dried on 6.35 mu m Mylar filmat 60 degrees C. The excitation was carried out using an X-ray tube with Mo target and Zr filter operated at 30 kV/ 20 mA. For SRTXRF, 10 mu l of the samplewere pipetted on a Lucite carrier and dried at 60 degrees C. In both the techniques, Ga was used as internal standard and the acquisition time was 200 s. The trueness of both techniques was evaluated through the standard addition method, the recoveries obtained by SRTXRF and EDXRF were 76 and 99%, and the limits of detection, 13 and 240 mu g l(-1), respectively. Copyright (C) 2011 John Wiley & Sons, Ltd.en
dc.description.affiliationUniv São Paulo, CENA, LIN, BR-13400970 Piracicaba, SP, Brazil
dc.description.affiliationUniv Estadual Paulista Julio de Mesquita Filho UN, CEA, BR-13506900 Rio Claro, SP, Brazil
dc.description.affiliationUniv São Paulo, Escola Super Agr Luiz de Queiroz ESALQ, Dept Zootecnia, LNCA, BR-13418970 Piracicaba, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista Julio de Mesquita Filho UN, CEA, BR-13506900 Rio Claro, SP, Brazil
dc.description.sponsorshipLaboratório Nacional de Luz Síncrotron (LNLS)
dc.description.sponsorshipIdLNLS - Brazilian Synchrotron Light Laboratory: D09-XRF-6648
dc.format.extent424-426
dc.identifierhttp://dx.doi.org/10.1002/xrs.1361
dc.identifier.citationX-ray Spectrometry. Hoboken: Wiley-blackwell, v. 40, n. 6, p. 424-426, 2011.
dc.identifier.doi10.1002/xrs.1361
dc.identifier.issn0049-8246
dc.identifier.urihttp://hdl.handle.net/11449/40360
dc.identifier.wosWOS:000297053400005
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofX-Ray Spectrometry
dc.relation.ispartofjcr1.077
dc.relation.ispartofsjr0,426
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.titleDetermination of cobalt marker in cow ruminal fluid by EDXRF and SRTXRFen
dc.typeArtigo
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell
dspace.entity.typePublication
unesp.author.orcid0000-0002-1111-9758[3]
unesp.author.orcid0000-0002-7082-8853[3]

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: