Installation of a getter vacuum pump in cathode-anode region of a high-power klystron amplifier - Propose and feasible

Carregando...
Imagem de Miniatura

Orientador

Coorientador

Pós-graduação

Curso de graduação

Título da Revista

ISSN da Revista

Título de Volume

Editor

Tipo

Trabalho apresentado em evento

Direito de acesso

Acesso abertoAcesso Aberto

Resumo

The possibility to install a getter vacuum pump and its feasible in the anode of a high-power klystron amplifier is investigated in order to decrease of the pressure in the gun and consequently increasing its lifetime. The study is conducted using a 1.3 GHz, 100 A and 240 kV high-power klystron with five reentrant coaxial cavities, assembled in a cylindrical drift tube 1.2 m long. This work takes into account the specific conductance of components of gun and all important gas sources, like the degassing of the drift tube, the cavity walls, the cathode, the anode, and the collector, as well the position and pumping speed of the getter vacuum pump in anode region. © 2006 IEEE.

Descrição

Palavras-chave

Getter, High-vacuum modeling, Ultra high-vacuum system, Vacuum pressure field, Amplifiers (electronic), Anodes, Cathodes, Electron tubes, Getters, Klystrons, High vacuum modeling, Ultra high vacuum system, Vacuum pumps

Idioma

Inglês

Como citar

2006 IEEE International Vacuum Electronics Conference held jointly with 2006 IEEE International Vacuum Electron Sources, IVEC/IVESC 2006, p. 233-234.