Publicação: Nanoporous silk films with capillary action and size-exclusion capacity for sensitive glucose determination in whole blood
dc.contributor.author | Márquez, Augusto | |
dc.contributor.author | Santos, Moliria V. | |
dc.contributor.author | Guirado, Gonzalo | |
dc.contributor.author | Moreno, Alex | |
dc.contributor.author | Aznar-Cervantes, Salvador D. | |
dc.contributor.author | Cenis, Jose Luis | |
dc.contributor.author | Santagneli, Silvia H. [UNESP] | |
dc.contributor.author | Domínguez, Carlos | |
dc.contributor.author | Omenetto, Fiorenzo G. | |
dc.contributor.author | Muñoz-Berbel, Xavier | |
dc.contributor.institution | CSIC) | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.contributor.institution | Universitat Autònoma de Barcelona Bellaterra (Barcelona) | |
dc.contributor.institution | Instituto Murciano de Investigación y Desarrollo Agrario y Alimentario (IMIDA) | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Tufts University | |
dc.date.accessioned | 2021-06-25T10:22:39Z | |
dc.date.available | 2021-06-25T10:22:39Z | |
dc.date.issued | 2021-02-07 | |
dc.description.abstract | In optical biosensing, silk fibroin (SF) appears as a promising alternative where other materials, such as paper, find limitations. Besides its excellent optical properties and unmet capacity to stabilize biomacromolecules, SF in test strips exhibits additional functions,i.e.capillary pumping activity of 1.5 mm s−1, capacity to filter blood cells thanks to its small, but tuneable, porosity and enhanced biosensing sensitivity. The bulk functionalization of SF with the enzymes glucose oxidase and peroxidase and the mediator ABTS produces colourless and transparent SF films that respond to blood glucose increasing 2.5 times the sensitivity of conventional ABTS-based assays. This enhanced sensitivity results from the formation of SF-ABTS complexes, where SF becomes part of the bioassay. Additionally, SF films triple the durability of most stable cellulose-based sensors. Although demonstrated for glucose, SF microfluidic test strips may incorporate other optical bioassays,e.g.immunoassays, with the aim of transferring them from central laboratories to the place of patient's care. | en |
dc.description.affiliation | Instituto de Microelectrónica de Barcelona (IMB-CNM CSIC) | |
dc.description.affiliation | São Carlos Institute of Physics University of São Paulo | |
dc.description.affiliation | Departament de Química Universitat Autònoma de Barcelona Bellaterra (Barcelona) | |
dc.description.affiliation | Instituto Murciano de Investigación y Desarrollo Agrario y Alimentario (IMIDA) | |
dc.description.affiliation | Institute of Chemistry São Paulo State University (UNESP) | |
dc.description.affiliation | Silklab Department of Biomedical Engineering Tufts University | |
dc.description.affiliation | Department of Electrical and Computer Engineering Tufts University | |
dc.description.affiliation | Department of Physics Tufts University | |
dc.description.affiliation | Laboratory for Living Devices Tufts University | |
dc.description.affiliationUnesp | Institute of Chemistry São Paulo State University (UNESP) | |
dc.format.extent | 608-615 | |
dc.identifier | http://dx.doi.org/10.1039/d0lc00702a | |
dc.identifier.citation | Lab on a Chip, v. 21, n. 3, p. 608-615, 2021. | |
dc.identifier.doi | 10.1039/d0lc00702a | |
dc.identifier.issn | 1473-0189 | |
dc.identifier.issn | 1473-0197 | |
dc.identifier.scopus | 2-s2.0-85100812402 | |
dc.identifier.uri | http://hdl.handle.net/11449/205874 | |
dc.language.iso | eng | |
dc.relation.ispartof | Lab on a Chip | |
dc.source | Scopus | |
dc.title | Nanoporous silk films with capillary action and size-exclusion capacity for sensitive glucose determination in whole blood | en |
dc.type | Artigo | pt |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |