Logo do repositório

Comparação da força retentiva entre grampos estéticos e metálicos para prótese parcial removível

dc.contributor.authorYamamoto, Eron Toshio Colauto
dc.contributor.authorSato, Tabata Prado [UNESP]
dc.contributor.authorda Silva, João Mauricio Ferraz [UNESP]
dc.contributor.authorBorges, Alexandre Luiz Souto [UNESP]
dc.contributor.authorUemura, Eduardo Shigueyuki [UNESP]
dc.contributor.institutionUniversidade Nove de Julho Dental School
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T17:34:43Z
dc.date.available2018-12-11T17:34:43Z
dc.date.issued2017-07-01
dc.description.abstractObjective: This study aimed to evaluate the retention of acetate resin clasp as when compared to metal clasp. Material and methods: For this purpose, we constructed 10 conventional Co-Cr metal clasps (Ackers) and 20 acetate resin clasps. The acetate resin clasps had the opposition, support and retaining arms made of Co-Cr. Of the 20 esthetic clasps, 10 had the thickness of the retention arm decreased to make it more esthetic. The initial retentive force of the specimens was tested in a universal testing machine through tensile test. After that, the specimens were subjected to 7,000 cycles, each one, in an adapted machine, immersed into artificial saliva, for 36 months of simulated clinical use of a removable partial denture. Data were tabulated for statistical analysis of the retention effectiveness. Results: After cycling, 3-mm-thick and 2-mmthick acetate resin clasps lost more retention than metal clasps. The material type (p=0.0000) and cycling (p=0.0039) showed a significant effect, but the material/cycling interaction (p=0.1436) did not. Conclusions: Therefore, esthetic clasps presented retention force lower than that of metal clasps. Notwithstanding, the esthetic clasps can be used in clinical cases requiring minimum retention.en
dc.description.affiliationDepartment of Prosthodontics Universidade Nove de Julho Dental School
dc.description.affiliationSão Paulo State University (Unesp) Institute of Science and Technology Department of Dental Materials and Prosthodontics
dc.description.affiliationUnespSão Paulo State University (Unesp) Institute of Science and Technology Department of Dental Materials and Prosthodontics
dc.format.extent87-92
dc.identifierhttp://dx.doi.org/10.14295/bds.2017.v20i3.1431
dc.identifier.citationBrazilian Dental Science, v. 20, n. 3, p. 87-92, 2017.
dc.identifier.doi10.14295/bds.2017.v20i3.1431
dc.identifier.issn2178-6011
dc.identifier.scopus2-s2.0-85032694579
dc.identifier.urihttp://hdl.handle.net/11449/179323
dc.language.isoeng
dc.relation.ispartofBrazilian Dental Science
dc.rights.accessRightsAcesso restrito
dc.sourceScopus
dc.subjectEsthetic clasp
dc.subjectMetal clasp
dc.subjectRemovable partial denture
dc.titleComparação da força retentiva entre grampos estéticos e metálicos para prótese parcial removívelpt
dc.title.alternativeRetentive force comparison between esthetic and metal clasps for removable partial dentureen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes6043459304176015[4]
unesp.author.orcid0000-0002-5707-7565[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentMateriais Odontológicos e Prótese - ICTpt