Publicação: Effect of storage and aging conditions on the flexural strength and flexural modulus of CAD/CAM materials
dc.contributor.author | Porto, Thiago Soares | |
dc.contributor.author | Roperto, Renato Cassio | |
dc.contributor.author | Akkus, Anna | |
dc.contributor.author | Akkus, Ozan | |
dc.contributor.author | Teich, Sorin | |
dc.contributor.author | Faddoul, Fady | |
dc.contributor.author | Porto-neto, Sizenando Toledo [UNESP] | |
dc.contributor.author | Campos, Edson Alves [UNESP] | |
dc.contributor.institution | Case Western Reserve Univ | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2019-10-04T12:38:15Z | |
dc.date.available | 2019-10-04T12:38:15Z | |
dc.date.issued | 2019-04-01 | |
dc.description.abstract | Computer-aided design/computer-aided manufacturing (CAD/CAM) materials were submitted to thermocycling, to identify changes in mechanical behavior. Four CAD/CAM materials were divided in four subordinate groups (n=9): (1) dry out for 7 days, (2) distilled water at 37 degrees C for 7 days, (3) 60,000 thermocycles, and (4) 120,000 thermocycles. Following thermocycling, samples were submitted to three-point bending test. Two-way ANOVA and post-hoc Tukey's test were performed (alpha=0.05). The IPS e.max CAD had a flexural strength of 396 +/- 75 MPa and flexural modulus of 84 +/- 11 GPa, followed by Vita Enamic with values of 153 +/- 17 MPa and 28 +/- 5 GPa respectively. The flexural strength recorded for Lava Ultimate was 149 +/- 28 MPa and the flexural modulus was 12 +/- 3 GPa. Vitablocs Mark II had the lowest flexural strength values (125 +/- 10 MPa) and a flexural modulus of 49 +/- 15 GPa. Although polymer-based materials have similar mechanical properties compared to ceramics, they are affected by thermo cycling conditions. | en |
dc.description.affiliation | Case Western Reserve Univ, Sch Dent Med, Dept Comprehens Care, 2124 Cornell Rd, Cleveland, OH 44106 USA | |
dc.description.affiliation | Case Western Reserve Univ, Sch Engn, Dept Macromol Sci & Engn, 10900 Euclid Ave, Cleveland, OH 44106 USA | |
dc.description.affiliation | Case Western Reserve Univ, Sch Engn, Dept Mech & Aerosp Engn, 10900 Euclid Ave, Cleveland, OH 44106 USA | |
dc.description.affiliation | Sao Paulo State Univ, Araraquara Fac Dent, Dept Restorat Dent, Rua Humaita 1680, BR-14801385 Araraquara, SP, Brazil | |
dc.description.affiliationUnesp | Sao Paulo State Univ, Araraquara Fac Dent, Dept Restorat Dent, Rua Humaita 1680, BR-14801385 Araraquara, SP, Brazil | |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.description.sponsorshipId | CAPES: 99999.008214/201400 | |
dc.format.extent | 264-270 | |
dc.identifier | http://dx.doi.org/10.4012/dmj.2018-111 | |
dc.identifier.citation | Dental Materials Journal. Tokyo: Japanese Soc Dental Materials Devices, v. 38, n. 2, p. 264-270, 2019. | |
dc.identifier.doi | 10.4012/dmj.2018-111 | |
dc.identifier.issn | 0287-4547 | |
dc.identifier.uri | http://hdl.handle.net/11449/185746 | |
dc.identifier.wos | WOS:000469158900014 | |
dc.language.iso | eng | |
dc.publisher | Japanese Soc Dental Materials Devices | |
dc.relation.ispartof | Dental Materials Journal | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | Ceramics | |
dc.subject | CAD/CAM | |
dc.subject | Chipping | |
dc.subject | Brittle ceramics | |
dc.subject | Flexural strength | |
dc.title | Effect of storage and aging conditions on the flexural strength and flexural modulus of CAD/CAM materials | en |
dc.type | Artigo | |
dcterms.rightsHolder | Japanese Soc Dental Materials Devices | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Odontologia Restauradora - FOAR | pt |