Publicação: Effect of dental finishing instruments on the surface roughness of composite resins as elucidated by atomic force microscopy
dc.contributor.author | Botta, Ana Carolina [UNESP] | |
dc.contributor.author | Duarte, Sillas | |
dc.contributor.author | Paulin Filho, Pedro Iris | |
dc.contributor.author | Gheno, Simoni Maria | |
dc.contributor.institution | Case Western Reserve Univ | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade Federal de São Carlos (UFSCar) | |
dc.date.accessioned | 2014-05-20T14:05:24Z | |
dc.date.available | 2014-05-20T14:05:24Z | |
dc.date.issued | 2008-10-01 | |
dc.description.abstract | Roughness increases significantly after finishing procedures. The aim of this study was to assess by the atomic force microscope (AFM) the effect of finishing instruments on the surface roughness of composite resins. A nanofiller composite resin (Filtek Supreme, 3M-F) and a microhybrid composite resin (Point 4, Kerr-P) were selected. The finishing procedures were done with a 30-blade carbide bur (C) and a 30-mu m finishing diamond bur (D). Standardized specimens were produced and divided into six experimental groups (n = 4) according to (1) composite resin, (2) absence of finishing (Mylar matrix-M), and (3) finishing instrument (FM, PM, FC, FD, PC, PD). The mean surface roughness was evaluated by AFM in the contact mode. FM and PM groups were assessed statistically by the Student's T test, and FC, FD, PC, PD groups were submitted to variance analysis (ANOVA), both at 5% significance. The mean surface roughness values, in nanometers, were FM, 23.63 (b); FC, 283.88 (c); FD, 510.55 (d); PM, 12.52 (a); PC, 343.98 (c); PD, 531.64 (d). Microhybrid composite displayed less roughness than nanofiller composite in the absence of finishing procedures. The 30-blade carbide bur produced less roughness compared to the extra fine diamond bur. | en |
dc.description.affiliation | Case Western Reserve Univ, Case Sch Dent Med, Dept Comprehens Care, Cleveland, OH 44106 USA | |
dc.description.affiliation | Univ Estadual Paulista, Sao Jose Campos Sch Dent, Dept Restorat Dent, BR-12245000 São Paulo, Brazil | |
dc.description.affiliation | Universidade Federal de São Carlos (UFSCar), Dept Mat Engn, BR-13565905 São Carlos, SP, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Sao Jose Campos Sch Dent, Dept Restorat Dent, BR-12245000 São Paulo, Brazil | |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.description.sponsorship | Department of Materials Engineering of the Federal University of São Carlos | |
dc.description.sponsorshipId | CAPES: 33004030008M8 | |
dc.format.extent | 380-386 | |
dc.identifier | http://dx.doi.org/10.1017/S1431927608080768 | |
dc.identifier.citation | Microscopy and Microanalysis. New York: Cambridge Univ Press, v. 14, n. 5, p. 380-386, 2008. | |
dc.identifier.doi | 10.1017/S1431927608080768 | |
dc.identifier.file | WOS000259650800002.pdf | |
dc.identifier.issn | 1431-9276 | |
dc.identifier.uri | http://hdl.handle.net/11449/22949 | |
dc.identifier.wos | WOS:000259650800002 | |
dc.language.iso | eng | |
dc.publisher | Cambridge University Press | |
dc.relation.ispartof | Microscopy and Microanalysis | |
dc.relation.ispartofjcr | 2.124 | |
dc.relation.ispartofsjr | 0,292 | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Web of Science | |
dc.subject | atomic force microscopy | en |
dc.subject | surface roughness | en |
dc.subject | carbide bur | en |
dc.subject | diamond bur | en |
dc.subject | nanofiller composite resin | en |
dc.subject | microhybrid composite resin | en |
dc.subject | finishing techniques | en |
dc.title | Effect of dental finishing instruments on the surface roughness of composite resins as elucidated by atomic force microscopy | en |
dc.type | Artigo | |
dcterms.license | http://journals.cambridge.org/action/displaySpecialPage?pageId=4676# | |
dcterms.rightsHolder | Cambridge Univ Press | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campos | pt |
unesp.department | Odontologia Restauradora - ICT | pt |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- WOS000259650800002.pdf
- Tamanho:
- 325.18 KB
- Formato:
- Adobe Portable Document Format
Licença do Pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: