Logo do repositório

Continuous measurement of arterial oxygenation in mechanically ventilated horses

dc.contributor.authorHummer, Emma V.
dc.contributor.authorSoares, Joao H. N.
dc.contributor.authorCrockett, Douglas C.
dc.contributor.authorAguiar, Antonio J. A. [UNESP]
dc.contributor.authorTran, Minh C.
dc.contributor.authorCronin, John N.
dc.contributor.authorBrosnan, Robert J.
dc.contributor.authorBraun, Christina
dc.contributor.authorFormenti, Federico
dc.contributor.institutionUniversity of California Davis
dc.contributor.institutionUniversity of Oxford
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionKing’s College London
dc.contributor.institutionGuy’s and St Thomas’ NHS Foundation Trust
dc.contributor.institutionVetmeduni Vienna
dc.date.accessioned2022-04-29T08:37:58Z
dc.date.available2022-04-29T08:37:58Z
dc.date.issued2021-01-01
dc.description.abstractBackground: The possibility of accurately and continuously measuring arterial oxygen partial pressure (PaO2) in horses may facilitate the management of hypoxaemia during general anaesthesia. Objectives: The aim of this study was to evaluate the ability of a novel fibreoptic sensor to measure PaO2 (PaO2Sensor) continuously and in real time in horses undergoing ventilatory manoeuvres during general anaesthesia. Study design: In vivo experimental study. Methods: Six adult healthy horses were anaesthetised and mechanically ventilated in dorsal recumbency. A fibreoptic sensor was placed in one of the facial arteries through a catheter to continuously measure and record PaO2Sensor. After an alveolar recruitment manoeuvre, a decremental positive end-expiratory pressure (PEEP) titration using 20-minute steps of 5 cm H2O from 20 to 0 cm H2O was performed. An arterial blood sample was collected at 15 minutes of ventilation at each PEEP level for PaO2 measurement using an automated blood gas machine (PaO2Ref). The agreement between PaO2Sensor and PaO2Ref was assessed by Pearson's correlation, Bland-Altman plot and four-quadrant plot analysis. In the last minute of ventilation at each PEEP level, a slow tidal inflation/deflation manoeuvre was performed. Results: The mean relative bias between PaO2Sensor and PaO2Ref was 4% with limits of agreement between −17% and 29%. The correlation coefficient between PaO2Sensor and PaO2Ref was 0.98 (P <.001). The PaO2Sensor and PaO2Ref concordance rate for changes was 95%. Measurements of PaO2Sensor during the slow inflation/deflation manoeuvre at PEEP 15 and 10 cm H2O were not possible because of significant noise on the PaO2 signal generated by a small blood clot. Main limitations: Small sample size. Conclusion: The tested fibreoptic probe was able to accurately and continuously measure PaO2Sensor in anaesthetised horses undergoing ventilatory manoeuvres. A heparinised system in the catheter used by the fibreoptic sensor should be used to avoid blood clots and artefacts in the PaO2 measurements.en
dc.description.affiliationWilliam Pritchard Veterinary Medical Teaching Hospital University of California Davis
dc.description.affiliationDepartment of Surgical and Radiological Sciences School of Veterinary Medicine University of California Davis
dc.description.affiliationNuffield Division of Anaesthetics University of Oxford
dc.description.affiliationDepartamento de Cirurgia e Anestesiologia Veterinária Faculdade de Medicina Veterinária e Zootecnia UNESP – Univ. Estadual Paulista
dc.description.affiliationDepartment of Engineering Science University of Oxford
dc.description.affiliationCentre for Human and Applied Physiological Sciences King’s College London
dc.description.affiliationDepartment of Anaesthetics Guy’s and St Thomas’ NHS Foundation Trust
dc.description.affiliationAnaesthesiology and Perioperative Intensive Care Vetmeduni Vienna
dc.description.affiliationUnespDepartamento de Cirurgia e Anestesiologia Veterinária Faculdade de Medicina Veterinária e Zootecnia UNESP – Univ. Estadual Paulista
dc.identifierhttp://dx.doi.org/10.1111/evj.13542
dc.identifier.citationEquine Veterinary Journal.
dc.identifier.doi10.1111/evj.13542
dc.identifier.issn2042-3306
dc.identifier.issn0425-1644
dc.identifier.scopus2-s2.0-85121609854
dc.identifier.urihttp://hdl.handle.net/11449/230103
dc.language.isoeng
dc.relation.ispartofEquine Veterinary Journal
dc.sourceScopus
dc.subjectanaesthesia
dc.subjectarterial oxygenation
dc.subjectartificial ventilation
dc.subjecthorse
dc.titleContinuous measurement of arterial oxygenation in mechanically ventilated horsesen
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublication9ca5a87b-0c83-43fa-b290-6f8a4202bf99
relation.isOrgUnitOfPublication.latestForDiscovery9ca5a87b-0c83-43fa-b290-6f8a4202bf99
unesp.author.orcid0000-0001-9044-3208[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina Veterinária e Zootecnia, Botucatupt
unesp.departmentCirurgia e Anestesiologia Veterinária - FMVZpt

Arquivos