Publicação: Multiplane ultrasound approach to quantify pleural effusion at the bedside
dc.contributor.author | Remerand, Francis | |
dc.contributor.author | Dellamonica, Jean | |
dc.contributor.author | Mao, Zhang | |
dc.contributor.author | Ferrari, Fabio [UNESP] | |
dc.contributor.author | Bouhemad, Belaid | |
dc.contributor.author | Yang Jianxin, | |
dc.contributor.author | Arbelot, Charlotte | |
dc.contributor.author | Lu, Qin | |
dc.contributor.author | Ichai, Carole | |
dc.contributor.author | Rouby, Jean-Jacques | |
dc.contributor.institution | Hop La Pitie Salpetriere | |
dc.contributor.institution | UPMC | |
dc.contributor.institution | CHRU Tours | |
dc.contributor.institution | Ctr Hosp Univ Nice | |
dc.contributor.institution | Zhejiang Univ | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T13:32:07Z | |
dc.date.available | 2014-05-20T13:32:07Z | |
dc.date.issued | 2010-04-01 | |
dc.description.abstract | To assess the accuracy of a multiplane ultrasound approach to measure pleural effusion volume (PEV), considering pleural effusion (PE) extension along the cephalocaudal axis and PE area.Prospective study performed on 58 critically ill patients with 102 PEs. Thoracic drainage was performed in 46 patients (59 PEs) and lung computed tomography (CT) in 24 patients (43 PEs). PE was assessed using bedside lung ultrasound. Adjacent paravertebral intercostal spaces were examined, and ultrasound PEV was calculated by multiplying the paravertebral PE length by its area, measured at half the distance between the apical and caudal limits of the PE.Ultrasound PEV was compared to either the volume of the drained PE (59 PE) or PEV assessed on lung CT (43 PE). In patients with lung CT, the accuracy of this new method was compared to the accuracy of previous methods proposed for PEV measurement. Ultrasound PEV was tightly correlated with drained PEV (r = 0.84, p < 0.001) and with CT PEV (r = 0.90, p < 0.001). The mean biases between ultrasound and actual volumes of PE were -33 ml when compared to drainage (limits of agreement -292 to +227 ml) and -53 ml when compared to CT (limits of agreement -303 to +198 ml). This new method was more accurate than previous methods to measure PEV.Using a multiplane approach increases the accuracy of lung ultrasound to measure the volume of large to small pleural effusions in critically ill patients. | en |
dc.description.affiliation | Hop La Pitie Salpetriere, AP HP, Dept Anesthesie Reanimat, F-75013 Paris, France | |
dc.description.affiliation | UPMC, Univ Paris 06, Hop La Pitie Salpetriere, AP HP,Dept Anesthesiol & Crit Care Med,Multidisci, Paris, France | |
dc.description.affiliation | CHRU Tours, Hop Trousseau, Groupement Anesthesie Reanimat, F-37044 Tours 1, France | |
dc.description.affiliation | Ctr Hosp Univ Nice, Hop Archet, Nice, France | |
dc.description.affiliation | Zhejiang Univ, Affiliated Hosp 2, Hangzhou 310003, Zhejiang, Peoples R China | |
dc.description.affiliation | Univ Estadual Paulista, Fac Med, Dept Anesthesiol, Botucatu, SP, Brazil | |
dc.description.affiliation | Ctr Hosp Univ Nice, Hop St Roch, Surg Intens Care Unit, Dept Anesthesie & Reanimat, Nice, France | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Fac Med, Dept Anesthesiol, Botucatu, SP, Brazil | |
dc.format.extent | 656-664 | |
dc.identifier | http://dx.doi.org/10.1007/s00134-010-1769-9 | |
dc.identifier.citation | Intensive Care Medicine. New York: Springer, v. 36, n. 4, p. 656-664, 2010. | |
dc.identifier.doi | 10.1007/s00134-010-1769-9 | |
dc.identifier.issn | 0342-4642 | |
dc.identifier.uri | http://hdl.handle.net/11449/10958 | |
dc.identifier.wos | WOS:000275548400011 | |
dc.language.iso | eng | |
dc.publisher | Springer | |
dc.relation.ispartof | Intensive Care Medicine | |
dc.relation.ispartofjcr | 15.008 | |
dc.relation.ispartofsjr | 3,293 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | Pleural effusion | en |
dc.subject | Critical care | en |
dc.subject | Ultrasound imaging | en |
dc.subject | Computed tomography scan | en |
dc.subject | Pleural drainage | en |
dc.title | Multiplane ultrasound approach to quantify pleural effusion at the bedside | en |
dc.type | Artigo | |
dcterms.license | http://www.springer.com/open+access/authors+rights?SGWID=0-176704-12-683201-0 | |
dcterms.rightsHolder | Springer | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0001-9092-4642[10] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatu | pt |
unesp.department | Anestesiologia - FMB | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: