Logo do repositório
 

Evaluation of Impression Accuracy for Implant at Various Angulations

dc.contributor.authorAssunção, Wirley Goncalves [UNESP]
dc.contributor.authorBritto, Rebeca Cavalcante
dc.contributor.authorRicardo Barao, Valentim Adelino [UNESP]
dc.contributor.authorDelben, Juliana Aparecida [UNESP]
dc.contributor.authorSantos, Paulo Henrique dos [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:29:51Z
dc.date.accessioned2014-05-20T13:43:35Z
dc.date.available2013-09-30T18:29:51Z
dc.date.available2014-05-20T13:43:35Z
dc.date.issued2010-04-01
dc.description.abstractPurpose: The purpose of this study was to compare 2 splinted impression transfer techniques for implant-supported prostheses.Materials: A metal matrix (control) with 4 implants was used. The implants were positioned at 90, 80, 75, and 65 degrees in relation to the surface of the matrix. Squared impression copings were splinted with self-curing acrylic resin in group 1 (n = 10) and with condensation silicone in group 2 (n = 10). A computer software was used to measure the implants/analogs inclinations. Data were analyzed by 2-way analysis of variance and Tukey test (alpha <0.05).Results: There was significant difference between groups, implant/analog inclinations, and interaction between them (P < 0.05). Group 1 had no significant difference from the control (P > 0.05) nor from group 2 (P > 0.05) regardless implant/analog inclinations. Considering implant/analog inclinations, both techniques did not differ from control group (P > 0.05), except for 75 degrees implant/analog inclinations (P < 0.05).Conclusion: The results suggest that condensation silicone may not be used as an alternative splinting material. Furthermore, implant inclination may affect master cast accuracy. (Implant Dent 2010;19:167-174)en
dc.description.affiliationUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 São Paulo, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 01/13790-2
dc.description.sponsorshipIdFAPESP: 01/13791-9
dc.format.extent167-174
dc.identifierhttp://dx.doi.org/10.1097/ID.0b013e3181cd715f
dc.identifier.citationImplant Dentistry. Philadelphia: Lippincott Williams & Wilkins, v. 19, n. 2, p. 167-174, 2010.
dc.identifier.doi10.1097/ID.0b013e3181cd715f
dc.identifier.issn1056-6163
dc.identifier.lattes4438747643373395
dc.identifier.lattes0493479801083622
dc.identifier.orcid0000-0002-4100-5153
dc.identifier.urihttp://hdl.handle.net/11449/15215
dc.identifier.wosWOS:000276564300011
dc.language.isoeng
dc.publisherLippincott Williams & Wilkins
dc.relation.ispartofImplant Dentistry
dc.relation.ispartofjcr1.307
dc.relation.ispartofsjr0,712
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectdental implantsen
dc.subjectprosthodonticsen
dc.subjectimpression techniqueen
dc.titleEvaluation of Impression Accuracy for Implant at Various Angulationsen
dc.typeArtigopt
dcterms.licensehttp://edmgr.ovid.com/spine/accounts/copyrightTransfer.pdf
dcterms.rightsHolderLippincott Williams & Wilkins
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes4438747643373395
unesp.author.lattes0493479801083622[5]
unesp.author.orcid0000-0002-4100-5153[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos

Licença do pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: