Evaluation of Impression Accuracy for Implant at Various Angulations
dc.contributor.author | Assunção, Wirley Goncalves [UNESP] | |
dc.contributor.author | Britto, Rebeca Cavalcante | |
dc.contributor.author | Ricardo Barao, Valentim Adelino [UNESP] | |
dc.contributor.author | Delben, Juliana Aparecida [UNESP] | |
dc.contributor.author | Santos, Paulo Henrique dos [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2013-09-30T18:29:51Z | |
dc.date.accessioned | 2014-05-20T13:43:35Z | |
dc.date.available | 2013-09-30T18:29:51Z | |
dc.date.available | 2014-05-20T13:43:35Z | |
dc.date.issued | 2010-04-01 | |
dc.description.abstract | Purpose: The purpose of this study was to compare 2 splinted impression transfer techniques for implant-supported prostheses.Materials: A metal matrix (control) with 4 implants was used. The implants were positioned at 90, 80, 75, and 65 degrees in relation to the surface of the matrix. Squared impression copings were splinted with self-curing acrylic resin in group 1 (n = 10) and with condensation silicone in group 2 (n = 10). A computer software was used to measure the implants/analogs inclinations. Data were analyzed by 2-way analysis of variance and Tukey test (alpha <0.05).Results: There was significant difference between groups, implant/analog inclinations, and interaction between them (P < 0.05). Group 1 had no significant difference from the control (P > 0.05) nor from group 2 (P > 0.05) regardless implant/analog inclinations. Considering implant/analog inclinations, both techniques did not differ from control group (P > 0.05), except for 75 degrees implant/analog inclinations (P < 0.05).Conclusion: The results suggest that condensation silicone may not be used as an alternative splinting material. Furthermore, implant inclination may affect master cast accuracy. (Implant Dent 2010;19:167-174) | en |
dc.description.affiliation | Univ Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 São Paulo, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 São Paulo, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorshipId | FAPESP: 01/13790-2 | |
dc.description.sponsorshipId | FAPESP: 01/13791-9 | |
dc.format.extent | 167-174 | |
dc.identifier | http://dx.doi.org/10.1097/ID.0b013e3181cd715f | |
dc.identifier.citation | Implant Dentistry. Philadelphia: Lippincott Williams & Wilkins, v. 19, n. 2, p. 167-174, 2010. | |
dc.identifier.doi | 10.1097/ID.0b013e3181cd715f | |
dc.identifier.issn | 1056-6163 | |
dc.identifier.lattes | 4438747643373395 | |
dc.identifier.lattes | 0493479801083622 | |
dc.identifier.orcid | 0000-0002-4100-5153 | |
dc.identifier.uri | http://hdl.handle.net/11449/15215 | |
dc.identifier.wos | WOS:000276564300011 | |
dc.language.iso | eng | |
dc.publisher | Lippincott Williams & Wilkins | |
dc.relation.ispartof | Implant Dentistry | |
dc.relation.ispartofjcr | 1.307 | |
dc.relation.ispartofsjr | 0,712 | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Web of Science | |
dc.subject | dental implants | en |
dc.subject | prosthodontics | en |
dc.subject | impression technique | en |
dc.title | Evaluation of Impression Accuracy for Implant at Various Angulations | en |
dc.type | Artigo | pt |
dcterms.license | http://edmgr.ovid.com/spine/accounts/copyrightTransfer.pdf | |
dcterms.rightsHolder | Lippincott Williams & Wilkins | |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isDepartmentOfPublication.latestForDiscovery | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.author.lattes | 4438747643373395 | |
unesp.author.lattes | 0493479801083622[5] | |
unesp.author.orcid | 0000-0002-4100-5153[5] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.department | Materiais odontológicos e Prótese - FOA | pt |
Arquivos
Licença do pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: