Repository logo

Influência da smear layer e sua espessura na adesão e citotoxicidade de um cimento de ionômero de vidro modificado por resina

Loading...
Thumbnail Image

Advisor

Costa, Carlos Alberto de Souza

Coadvisor

Graduate program

Ciências Odontológicas - FOAR

Undergraduate course

Journal Title

Journal ISSN

Volume Title

Publisher

Universidade Estadual Paulista (Unesp)

Type

Doctoral dissertation

Access right

Acesso abertoAcesso Aberto

Abstract

Abstract (portuguese)

O objetivo do presente estudo foi avaliar a citotoxicidade do cimento de ionômero de vidro modificado por resina (CIVMR) sobre células odontoblastóides MDPC- 23 cultivadas sob discos de dentina com ou sem smear layer de diferentes espessuras. Além disto, o estudo também investigou se a permanência ou a remoção da smear layer poderia interferir na resistência de união do material com o substrato dentinário. Para isto, 40 discos de dentina com espessura de 0,4mm foram obtidos de terceiros molares humanos hígidos. Após limpeza das superfícies dos discos com ácido etilenodiamino tetra-acético (EDTA, pH 7.2), medidas de condutância hidráulica foram realizadas como forma de padronização da permeabilidade entre os discos. Lixas d’água de granulação 180 e 600 foram utilizadas para a formação da smear layer espessa e delgada, respectivamente. Desta forma, a distribuição dos discos de dentina resultou nos seguintes grupos controle e experimentais: G1M - grupo controle; G2M – Smear layer Espessa + CIVMR; G3M – Smear layer Delgada + CIVMR; G4M – Smear layer Espessa Removida + CIV; G5M – Smear layer Delgada Removida + CIVMR. Após divisão e posicionamento dos discos em câmaras pulpares artificiais, 50.000 células odontoblástóides MDPC-23 foram cultivadas sobre sua superfície pulpar. Decorridos 48 horas do cultivo, o CIVMR VitrebondTM foi aplicado sobre a superfície oclusal dos mesmos discos de dentina com ou sem smear layer. Após 24 horas, o metabolismo das células foi determinado através da avaliação da atividade da desidrogenase succínica (MTT assay). A morfologia celular foi analisada em microscopia eletrônica de varredura (MEV). Para avaliação da resistência adesiva, outros 40 terceiros molares com dentina oclusal exposta tiveram o VitrebondTM aplicado dentro das mesmas condições já descritas (com ou sem smear layer). Os grupos experimentais...

Abstract (english)

The objective of present study was to evaluate the cytotoxicity of a resin-modified glass-ionomer cement (RMGIC) on odontoblast-like cells MDPC-23 plated under dentin discs when smear layer with different thickness was removed or not. In addition, it was also investigated whether presence or not of the smear layer could change in the bond strength of material on dentin substrate. Forty dentin discs with 0.4 mm thickness were obtained from caries and restoration free human third molars. The hydraulic conductance of all dentin discs was evaluated. One hundred eighty and 600-grit silicon carbide paper were employed to created thick and thin smear layer, respectively. Thereby, the distribution of dentin disc revealed the following experimental e control groups: G1M – control group; G2M – thick smear layer + RMGIC; G3M – thin smear layer + RMGIC; G4M – Thick smear layer Removed + RMGIC; G5M – Thin smear layer Removed + RMGIC. After adapting the dentin discs in artificial pulp chambers, the odontoblast like cells MDPC-23 (50.000 cells) were plated on the pulpal surface of these discs and incubated for 48 hours. Then the RMGIC VitrebondTM was applied on the oclusal surface of the dentin discs with or without smear layer. After 24h incubation, the cell metabolism was determined through evaluation of succínic desidrogenase enzime (MTT assay). The cell morphology was investigated by scanning electronic microscopy (SEM). To evaluate bond strength, VitrebondTM was applied on the oclusal dentin surface of 40 human third sound molars treated as previously reported (with or not smear layer of different thickness). The experimental and control groups were determined: G1R – Thick smear layer + EDTA + RMGIC; G2R - Thin smear layer + EDTA + RMGIC; G3R - Thick smear layer + RMGIC; G4R - Thin smear layer + RMGIC. Each specimen characterized by the VitrebondTM applied on the exposed and treated... (Complete abstract click electronic access below)

Description

Keywords

Cimentos de ionômero de vidro, Camada de esfregaço, Resistência ao cisalhamento, Metabolismo, Odontoblastos, Glass-ionomer cement, Odontoblast, Smear layer, Shear strength, Metabolism

Language

Portuguese

Citation

MENDONÇA, Adriano Augusto Melo de. Influência da smear layer e sua espessura na adesão e citotoxicidade de um cimento de ionômero de vidro modificado por resina. 2009. 141 f. Tese (doutorado) - Universidade Estadual Paulista, Faculdade de Odontologia de Araraquara, 2009.

Related itens

Units

Item type:Unit,
Faculdade de Odontologia
FOAR
Campus: Araraquara


Departments

Undergraduate courses

Graduate programs

Item type:Graduate program,