Logo do repositório
 

Evaluation of bond strength and thickness of adhesive layer according to the techniques of applying adhesives in composite resin restorations

dc.contributor.authorHueb de Menezes, Fernando Carlos
dc.contributor.authorSilva, Stella Borges da
dc.contributor.authorValentino, Thiago Assuncao
dc.contributor.authorHueb de Menezes Oliveira, Maria Angelica
dc.contributor.authorSouza Rastelli, Alessandra Nara de [UNESP]
dc.contributor.authorConcalves, Luciano de Souza
dc.contributor.institutionUniv Uberaba
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-12-03T13:10:50Z
dc.date.available2014-12-03T13:10:50Z
dc.date.issued2013-01-01
dc.description.abstractAdhesive restorations have increasingly been used in dentistry, and the adhesive system application technique may determine the success of the restorative procedure. The aim of this study was to evaluate the influence of the application technique of two adhesive systems (Clearfil SE Bond and Adper Scotchbond MultiPurpose) on the bond strength and adhesive layer of composite resin restorations. Eight human third molars were selected and prepared with Class I occlusal cavities. The teeth were restored with composite using various application techniques for both adhesives, according to the following groups (n = 10): group 1 (control), systems were applied and adhesive was immediately light activated for 20 seconds without removing excesses; group 2, excess adhesive was removed with a gentle jet of air for 5 seconds; group 3, excess was removed with a dry microbrush-type device; and group 4, a gentle jet of air was applied after the microbrush and then light activation was performed. After this, the teeth were submitted to microtensile testing. For the two systems tested, no statistical differences were observed between groups 1 and 2. Groups 3 and 4 presented higher bond strength values compared with the other studied groups, allowing the conclusion that excess adhesive removal with a dry micro-brush could improve bond strength in composite restorations. Predominance of adhesive fracture and thicker adhesive layer were observed via scanning electron microscopy (SEM) in groups 1 and 2. For groups 3 and 4, a mixed failure pattern and thinner adhesive layer were verified. Clinicians should be aware that excess adhesive may negatively affect bond strength, whereas a thin, uniform adhesive layer appears to be favorable. (Quintessence Int 2013;44:9-15)en
dc.description.affiliationUniv Uberaba, Biomat Div, Fac Dent Uberaba, Uberaba, MG, Brazil
dc.description.affiliationUNESP, Araraquara Sch Dent, Dept Restorat Dent, Araraquara, SP, Brazil
dc.description.affiliationUnespUNESP, Araraquara Sch Dent, Dept Restorat Dent, Araraquara, SP, Brazil
dc.format.extent9-15
dc.identifierhttp://dx.doi.org/10.3290/j.qi.a28737
dc.identifier.citationQuintessence International. Hanover Park: Quintessence Publishing Co Inc, v. 44, n. 1, p. 9-15, 2013.
dc.identifier.doi10.3290/j.qi.a28737
dc.identifier.issn0033-6572
dc.identifier.lattes6914969526213393
dc.identifier.urihttp://hdl.handle.net/11449/112563
dc.identifier.wosWOS:000317664300003
dc.language.isoeng
dc.publisherQuintessence Publishing Co Inc
dc.relation.ispartofQuintessence International
dc.relation.ispartofjcr1.088
dc.relation.ispartofsjr0,563
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectadhesive systemen
dc.subjectbond strengthen
dc.subjectcomposite resinen
dc.titleEvaluation of bond strength and thickness of adhesive layer according to the techniques of applying adhesives in composite resin restorationsen
dc.typeArtigopt
dcterms.rightsHolderQuintessence Publishing Co Inc
dspace.entity.typePublication
relation.isDepartmentOfPublication901124bf-5736-4432-b057-7c29dec84b50
relation.isDepartmentOfPublication.latestForDiscovery901124bf-5736-4432-b057-7c29dec84b50
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes6914969526213393
unesp.author.orcid0000-0003-0397-2895[6]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Restauradora - FOARpt

Arquivos