Logotipo do repositório
 

Publicação:
Comparison of the Polar S810i monitor and the ECG for the analysis of heart rate variability in the time and frequency domains

dc.contributor.authorVanderlei, L. C. M. [UNESP]
dc.contributor.authorSilva, R. A. [UNESP]
dc.contributor.authorPastre, C. M. [UNESP]
dc.contributor.authorAzevedo, Fábio Mícolis de [UNESP]
dc.contributor.authorGodoy, M. F.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionFaculdade de Medicina de São José do Rio Preto (FAMERP)
dc.date.accessioned2014-05-20T13:23:24Z
dc.date.available2014-05-20T13:23:24Z
dc.date.issued2008-10-01
dc.description.abstractThe aim of the present study was to compare heart rate variability (HRV) at rest and during exercise using a temporal series obtained with the Polar S810i monitor and a signal from a LYNX® signal conditioner (BIO EMG 1000 model) with a channel configured for the acquisition of ECG signals. Fifteen healthy subjects aged 20.9 ± 1.4 years were analyzed. The subjects remained at rest for 20 min and performed exercise for another 20 min with the workload selected to achieve 60% of submaximal heart rate. RR series were obtained for each individual with a Polar S810i instrument and with an ECG analyzed with a biological signal conditioner. The HRV indices (rMSSD, pNN50, LFnu, HFnu, and LF/HF) were calculated after signal processing and analysis. The unpaired Student t-test and intraclass correlation coefficient were used for data analysis. No statistically significant differences were observed when comparing the values analyzed by means of the two devices for HRV at rest and during exercise. The intraclass correlation coefficient demonstrated satisfactory correlation between the values obtained by the devices at rest (pNN50 = 0.994; rMSSD = 0.995; LFnu = 0.978; HFnu = 0.978; LF/HF = 0.982) and during exercise (pNN50 = 0.869; rMSSD = 0.929; LFnu = 0.973; HFnu = 0.973; LF/HF = 0.942). The calculation of HRV values by means of temporal series obtained from the Polar S810i instrument appears to be as reliable as those obtained by processing the ECG signal captured with a signal conditioner.en
dc.description.affiliationUniversidade Estadual Paulista Departamento de Fisioterapia
dc.description.affiliationUniversidade Estadual Paulista Curso de Especialização em Fisioterapia
dc.description.affiliationUniversidade Estadual Paulista Faculdade de Ciências e Tecnologia Laboratório de Fisioterapia Aplicada ao Movimento Humano
dc.description.affiliationFaculdade de Medicina de São José do Rio Preto (FAMERP) Departamento de Cardiologia e Cirurgia Cardiovascular
dc.description.affiliationUnespUniversidade Estadual Paulista Departamento de Fisioterapia
dc.description.affiliationUnespUniversidade Estadual Paulista Curso de Especialização em Fisioterapia
dc.description.affiliationUnespUniversidade Estadual Paulista Faculdade de Ciências e Tecnologia Laboratório de Fisioterapia Aplicada ao Movimento Humano
dc.description.sponsorshipFundação para o Desenvolvimento da UNESP (FUNDUNESP)
dc.description.sponsorshipIdFUNDUNESP: 00931/08-DFP
dc.format.extent854-859
dc.identifierhttp://dx.doi.org/10.1590/S0100-879X2008005000039
dc.identifier.citationBrazilian Journal of Medical and Biological Research. Associação Brasileira de Divulgação Científica, v. 41, n. 10, p. 854-859, 2008.
dc.identifier.doi10.1590/S0100-879X2008005000039
dc.identifier.fileS0100-879X2008001000004.pdf
dc.identifier.issn0100-879X
dc.identifier.lattes5860525135106995
dc.identifier.lattes2761396544058606
dc.identifier.lattes8632504024617088
dc.identifier.orcid0000-0002-4187-7058
dc.identifier.scieloS0100-879X2008001000004
dc.identifier.urihttp://hdl.handle.net/11449/7054
dc.identifier.wosWOS:000261171400004
dc.language.isoeng
dc.publisherAssociação Brasileira de Divulgação Científica (ABRADIC)
dc.relation.ispartofBrazilian Journal of Medical and Biological Research
dc.relation.ispartofjcr1.492
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectHeart rate variabilityen
dc.subjectAutonomic nervous systemen
dc.subjectExerciseen
dc.subjectSpectral analysisen
dc.subjectECGen
dc.subjectPolar S810i monitoren
dc.titleComparison of the Polar S810i monitor and the ECG for the analysis of heart rate variability in the time and frequency domainsen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes5860525135106995
unesp.author.lattes2761396544058606[3]
unesp.author.lattes8632504024617088[4]
unesp.author.orcid0000-0002-1891-3153[1]
unesp.author.orcid0000-0002-4187-7058[4]
unesp.author.orcid0000-0002-0213-6679[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências e Tecnologia, Presidente Prudentept
unesp.departmentFisioterapia - FCTpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0100-879X2008001000004.pdf
Tamanho:
462.92 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: